Loading...
Search for: physical-parameters
0.006 seconds
Total 52 records

    Simulation of thermal radiation in a micropolar fluid flow through a porous medium between channel walls

    , Article Journal of Thermal Analysis and Calorimetry ; Volume 144, Issue 3 , 2021 , Pages 941-953 ; 13886150 (ISSN) Ahmad, S ; Ashraf, M ; Ali, K ; Sharif University of Technology
    Springer Science and Business Media B.V  2021
    Abstract
    Among numerous methods which have been employed to reinforce the thermal efficiency in many systems, one is the thermal radiation which is a mode of heat transfer. Another way to improve the thermal efficiency is the utilization of the porous media. The present work includes the study of micropolar flow with allowance for thermal radiation through a resistive porous medium between channel walls. The governing coupled partial differential equations representing the flow model are transmuted into ordinary ones by using the suitable dimensionless coordinates, and then, quasi-linearization is employed to solve the set of relevant coupled ODEs. Effects of physical parameters on the flow under... 

    Automatic segmentation of brain MRI in high-dimensional local and non-local feature space based on sparse representation

    , Article Magnetic Resonance Imaging ; Volume 31, Issue 5 , 2013 , Pages 733-741 ; 0730725X (ISSN) Khalilzadeh, M. M ; Fatemizadeh, E ; Behnam, H ; Sharif University of Technology
    2013
    Abstract
    Automatic extraction of the varying regions of magnetic resonance images is required as a prior step in a diagnostic intelligent system. The sparsest representation and high-dimensional feature are provided based on learned dictionary. The classification is done by employing the technique that computes the reconstruction error locally and non-locally of each pixel. The acquired results from the real and simulated images are superior to the best MRI segmentation method with regard to the stability advantages. In addition, it is segmented exactly through a formula taken from the distance and sparse factors. Also, it is done automatically taking sparse factor in unsupervised clustering methods... 

    Comprehensive two-dimensional gas chromatography (GC×GC) retention time shift correction and modeling using bilinear peak alignment, correlation optimized shifting and multivariate curve resolution

    , Article Chemometrics and Intelligent Laboratory Systems ; Volume 117 , 2012 , Pages 80-91 ; 01697439 (ISSN) Parastar, H ; Jalali Heravi, M ; Tauler, R ; Sharif University of Technology
    Elsevier  2012
    Abstract
    A combination of peak alignment methods and multivariate curve resolution (MCR) is proposed for handling retention time shifts and modeling of comprehensive two-dimensional gas chromatographic (GC × GC) data in the case of univariate detection systems such as in flame ionization detection (FID) or in total ion current mass spectrometry (TIC-MS) detection. A new bilinear peak alignment (BPA) method, based on MCR, is first proposed to correct for progressive within run retention time shifts in GC × GC due to temperature programming effects on second chromatographic dimension. The performance of the proposed peak alignment method is compared to that of the correlation optimized warping (COW)... 

    Detemining the thickness of barriers and well of Resonance Tunneling Diodes by specified I-V characteristic

    , Article Applied Mechanics and Materials ; Volume 110-116 , 2012 , Pages 5464-5470 ; 16609336 (ISSN) ; 9783037852620 (ISBN) Shahhoseini, A ; Ghorbanalipour, S ; Faez, R ; Sharif University of Technology
    Abstract
    In this paper, a method of determining physical dimension of Double Barrier Quantum Well (DBQW) of Resonance Tunneling Diodes (RTDs) is presented by using I-V characteristic governing on them. In this procedure, first we have used performance metrics related to RTDs I-V characteristic such as Peak to Valley Current Ratio (PVCR), peak current density (JP), valley current density (JV) and Voltage Swing (VS), and by some other arbitrary points, we have fitted a curve to the RTD current-voltage equation by MATLAB software. Then we have obtained the physical parameter of I-V equation and adjusted some of them with modification coefficients. Next, by choosing the material of barriers and the well... 

    New modeling for moment-rotation behavior of bolted endplate connections

    , Article Scientia Iranica ; Volume 18, Issue 4 A , August , 2011 , Pages 827-834 ; 10263098 (ISSN) Mohamadi Shoore, M. R ; Mofid, M ; Sharif University of Technology
    2011
    Abstract
    A new exponential model to depict the moment-rotation (M-θ) relationship of Bolted Endplate Connections (BEC) is proposed. The proposed model represents an approach to the prediction of M-O curves, taking into account the possible failure modes and the deformation characteristics of the connection elements. The presented model has three physical parameters, along with two curve-fitted factors. These physical parameters are generated from dimensional details of the connection, as well as the material properties. By employing simplified connection behavioral models to estimate the connection M-θ behavior, analytical expressions for evaluating major connection parameters, such as initial... 

    Calculation of photon pulse height distribution using deterministic and Monte Carlo methods

    , Article Radiation Physics and Chemistry ; Volume 117 , December , 2015 , Pages 160-166 ; 0969806X (ISSN) Akhavan, A ; Vosoughi, N ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    Radiation transport techniques which are used in radiation detection systems comprise one of two categories namely probabilistic and deterministic. However, probabilistic methods are typically used in pulse height distribution simulation by recreating the behavior of each individual particle, the deterministic approach, which approximates the macroscopic behavior of particles by solution of Boltzmann transport equation, is being developed because of its potential advantages in computational efficiency for complex radiation detection problems. In current work linear transport equation is solved using two methods including collided components of the scalar flux algorithm which is applied by... 

    How to improve the thermal performance of pulsating heat pipes: A review on working fluid

    , Article Renewable and Sustainable Energy Reviews ; Volume 91 , 2018 , Pages 630-638 ; 13640321 (ISSN) Alhuyi Nazari, M ; Ahmadi, M. H ; Ghasempour, R ; Shafii, M. B ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Pulsating Heat Pipes (PHPs) are cooling devices that are compact in size and have an ability to transfer heat in low temperature differences. Working fluids strongly affect the thermal performance of PHPs. In this paper, effects of some thermophysical parameters relating to working fluids, such as boiling point, latent heat of vaporization, surface tension, thermal conductivity and dynamic viscosity, are presented based on experimental and numerical studies done in recent years. Addition of nanoparticles to fluids, or making nanofuild, is a new method of improving thermophysical properties of fluids. Recently, many studies are carried out on thermophysical properties of nano-fuild. Results... 

    Evaluation of bioactivity and biocompatibility of silk fibroin/TiO2 nanocomposite

    , Article Journal of Medical and Biological Engineering ; Volume 38, Issue 1 , February , 2018 , Pages 99-105 ; 16090985 (ISSN) Johari, N ; Madaah Hosseini, H. R ; Taromi, N ; Arasteh, S ; Kazemnejad, S ; Samadi Kuchaksaraei, A ; Sharif University of Technology
    Springer Berlin Heidelberg  2018
    Abstract
    Biodegradable polymer/bioceramic nanocomposites are osteoconductive and can accelerate healing of bone tissue. In this research, silk fibroin (SF)/titanium dioxide (TiO2) nanocomposites were synthesized using different concentrations of TiO2 nanoparticles (0, 5, 10, 15 and 20 wt%). The SF/TiO2 nanocomposites were studied in terms of bioactivity and biocompatibility. The in vitro assessment of osteoblasts compatibility indicated that SF inclusion rendered nanocomposite biocompatible whereas presence of TiO2 nanoparticles allowed the cells to adhere and grow on nanocomposite surface and enhanced the bioactivity of the composite. © 2017, Taiwanese Society of Biomedical Engineering  

    Elliptic inhomogeneities and inclusions in anti-plane couple stress elasticity with application to nano-composites

    , Article International Journal of Solids and Structures ; Volume 46, Issue 16 , 2009 , Pages 2978-2987 ; 00207683 (ISSN) Haftbaradaran, H ; Mohammadi Shodja, H ; Sharif University of Technology
    2009
    Abstract
    It is well-known that classical continuum theory has certain deficiencies in predicting material's behavior at the micro- and nanoscales, where the size effect is not negligible. Higher order continuum theories introduce new material constants into the formulation, making the interpretation of the size effect possible. One famous version of these theories is the couple stress theory, invoked to study the anti-plane problems of the elliptic inhomogeneities and inclusions in the present work. The formulation in elliptic coordinates leads to an exact series solution involving Mathieu functions. Subsequently, the elastic fields of a single inhomogeneity in conjunction with the Mori-Tanaka theory... 

    Study of two-layer tapered depth of interaction PET detector

    , Article Applied Radiation and Isotopes ; Volume 174 , 2021 ; 09698043 (ISSN) Behnamian, H ; Yousefnejad, S ; Shafiee, M ; Rafiei, A ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    Improving detection efficiency in small animal PET scanners without degrading spatial resolution is one of the main problems of these scanners. Commercial small animal PET scanners use different methods to achieve desirable levels of sensitivity and spatial resolution. GE Healthcare eXplore VISTA PET scanner uses double layer (LYSO-GSO) depth-of-interaction (DOI) capable cuboid detector modules. In this work, the design of GE Healthcare eXplore VISTA PET scanner is improved using tapered detector geometry instead of cuboid geometry. Using tapered detector geometry, the gaps between adjacent modules are filled and the sensitive volume has increased about 11.5%. The new designed PET scanner... 

    Dynamics of antimicrobial peptide encapsulation in carbon nanotubes: the role of hydroxylation

    , Article International Journal of Nanomedicine ; Volume 17 , 2022 , Pages 125-136 ; 11769114 (ISSN) Dehaghani, M.Z ; Yousefi, F ; Seidi, F ; Sajadi, S. M ; Rabiee, N ; Habibzadeh, S ; Esmaeili, A ; Mashhadzadeh, A. H ; Spitas, C ; Mostafavi, E ; Saeb, M. R ; Sharif University of Technology
    Dove Medical Press Ltd  2022
    Abstract
    Introduction: Carbon nanotubes (CNTs) have been widely employed as biomolecule carriers, but there is a need for further functionalization to broaden their therapeutic application in aqueous environments. A few reports have unraveled biomolecule–CNT interactions as a measure of response of the nanocarrier to drug-encapsulation dynamics. Methods: Herein, the dynamics of encapsulation of the antimicrobial peptide HA-FD-13 (accession code 2L24) into CNTs and hydroxylated CNTs (HCNTs) is discussed. Results: The van der Waals (vdW) interaction energy of CNT–peptide and HCNT–peptide complexes decreased, reaching −110.6 and −176.8 kcal.Mol−1, respectively, once encapsulation of the peptide inside... 

    Thorough tuning of the aspect ratio of gold nanorods using response surface methodology

    , Article Analytica Chimica Acta ; Volume 779 , 2013 , Pages 14-21 ; 00032670 (ISSN) Hormozi Nezhad, M. R ; Robatjazi, H ; Jalali Heravi, M ; Sharif University of Technology
    2013
    Abstract
    In the present work a central composite design based on response surface methodology (RSM) is employed for fine tuning of the aspect ratios of seed-mediated synthesized gold nanorods (GNRs). The relations between the affecting parameters, including ratio of l-ascorbic acid to Au3+ ions, concentrations of silver nitrate, CTAB, and CTAB-capped gold seeds, were explored using a RSM model. It is observed that the effect of each parameter on the aspect ratio of developing nanorods highly depends on the value of the other parameters. The concentrations of silver ions, ascorbic acid and seeds are found to have a high contribution in controlling the aspect ratios of NRs. The optimized parameters led... 

    Evaluation of the effects of process parameters on granule mean size in a conical high shear granulator using response surface methodology

    , Article Powder Technology ; Volume 237 , 2013 , Pages 186-190 ; 00325910 (ISSN) Ranjbarian, S ; Farhadi, F ; Sharif University of Technology
    2013
    Abstract
    Response surface methodology was used to investigate the effects of operating parameters such as impeller speed, binder mass and granulation time on the average size of granules produced in a lab scale conical high shear granulator. Two quadratic models were proposed to express granule mean size as a function of impeller speed and binder mass as well as impeller speed and granulation time. It was found out that in the studied domain, the influence of each parameter on granule size differs from one another. While increasing binder mass at constant quantity of powder increased the average size linearly, increasing impeller speed changed the mean size in accordance with quadratic trend. The... 

    Influence of the tip mass on the tip-sample interactions in TM-AFM

    , Article Ultramicroscopy ; Volume 111, Issue 8 , Jul , 2011 , Pages 1423-1436 ; 03043991 (ISSN) Pishkenari, H. N ; Meghdari, A ; Sharif University of Technology
    2011
    Abstract
    This paper focuses on the influences of the tip mass ratio (the ratio of the tip mass to the cantilever mass), on the excitation of higher oscillation eigenmodes and also on the tip-sample interaction forces in tapping mode atomic force microscopy (TM-AFM). A precise model for the cantilever dynamics capable of accurate simulations is essential for the investigation of the tip mass effects on the interaction forces. In the present work, the finite element method (FEM) is used for modeling the AFM cantilever to consider the oscillations of higher eigenmodes oscillations. In addition, molecular dynamics (MD) is used to calculate precise data for the tip-sample force as a function of tip... 

    Recent advances in capillary microextraction

    , Article TrAC - Trends in Analytical Chemistry ; Volume 73 , November , 2015 , Pages 64-80 ; 01659936 (ISSN) Bagheri, H ; Piri Moghadam, H ; Sharif University of Technology
    Elsevier  2015
    Abstract
    This review is mostly focused on the recently emerged methodologies for preparing the appropriate extracting media with enhanced capacity, stability and selectivity, which could be used in capillary microextraction (CME). We particularly consider conductive polymers, sol-gel-based materials, monolithic coatings, molecularly-imprinted polymers and xerogels. Moreover, we discuss recent advances in configuration of CME, array capillaries and unbreakable substrates  

    The effect of parameters of equilibrium-based 3-D biomechanical models on extracted muscle synergies during isometric lumbar exertion

    , Article Journal of Biomechanics ; Volume 49, Issue 6 , 2016 , Pages 967-973 ; 00219290 (ISSN) Eskandari, A. H ; Sedaghat Nejad, E ; Rashedi, E ; Sedighi, A ; Arjmand, N ; Parnianpour, M ; Sharif University of Technology
    Elsevier Ltd 
    Abstract
    A hallmark of more advanced models is their higher details of trunk muscles represented by a larger number of muscles. The question is if in reality we control these muscles individually as independent agents or we control groups of them called "synergy". To address this, we employed a 3-D biomechanical model of the spine with 18 trunk muscles that satisfied equilibrium conditions at L4/5, with different cost functions. The solutions of several 2-D and 3-D tasks were arranged in a data matrix and the synergies were computed by using non-negative matrix factorization (NMF) algorithms. Variance accounted for (VAF) was used to evaluate the number of synergies that emerged by the analysis, which... 

    Estimation of effective brain connectivity with dual kalman filter and EEG source localization methods

    , Article Australasian Physical and Engineering Sciences in Medicine ; Volume 40, Issue 3 , 2017 , Pages 675-686 ; 01589938 (ISSN) Rajabioun, M ; Motie Nasrabadi, A ; Shamsollahi, M. B ; Sharif University of Technology
    Abstract
    Effective connectivity is one of the most important considerations in brain functional mapping via EEG. It demonstrates the effects of a particular active brain region on others. In this paper, a new method is proposed which is based on dual Kalman filter. In this method, firstly by using a brain active localization method (standardized low resolution brain electromagnetic tomography) and applying it to EEG signal, active regions are extracted, and appropriate time model (multivariate autoregressive model) is fitted to extracted brain active sources for evaluating the activity and time dependence between sources. Then, dual Kalman filter is used to estimate model parameters or effective... 

    Postural control learning dynamics in Parkinson's disease: Early improvement with plateau in stability, and continuous progression in flexibility and mobility

    , Article BioMedical Engineering Online ; Volume 19, Issue 1 , 2020 Rahmati, Z ; Behzadipour, S ; Schouten, A. C ; Taghizadeh, G ; Firoozbakhsh, K ; Sharif University of Technology
    BioMed Central Ltd  2020
    Abstract
    Background: Balance training improves postural control in Parkinson's disease (PD). However, a systematic approach for the development of individualized, optimal training programs is still lacking, as the learning dynamics of the postural control in PD, over a training program, are poorly understood. Objectives: We investigated the learning dynamics of the postural control in PD, during a balance-training program, in terms of the clinical, posturographic, and novel model-based measures. Methods: Twenty patients with PD participated in a balance-training program, 3 days a week, for 6 weeks. Clinical tests assessed functional balance and mobility pre-training, mid-training, and post-training.... 

    Gain variation of Raman amplifier in silicon micro-ring coupled-resonator optical waveguides

    , Article Solid State Lasers and Amplifiers III, Strasbourg, 8 April 2008 through 10 April 2008 ; Volume 6998 , 2008 ; 0277786X (ISSN); 9780819471963 (ISBN) Daghigh Ahmadi, E ; Farman, F ; Taghiabadi, R ; Keyvaninia, S ; Bahrampour, A ; Sharif University of Technology
    2008
    Abstract
    The field enhancement in micro resonators causes the Raman amplification enhancement in them. Micro resonators can be connected to form sequence in variety of ways. The various structures such as single channel and double channel side coupled integrated space sequence of resonators (SClSSORs) can be used as Raman amplifier with different performances. In this paper, a silicon micro-ring coupled-resonator optical waveguide (CROW) is considered as a bandpass Raman amplifier. We introduce an iterative matrix method for analysis the CROW Raman amplifier. This method is applied to the single pump and single input for silicon CROW Raman amplifiers, and the effects of physical parameters of the... 

    Early post-operative performance of an anatomically designed hybrid thread interference screw for ACL reconstruction: A comparative study

    , Article Journal of Biomechanics ; Volume 135 , 2022 ; 00219290 (ISSN) Daneshvarhashjin, N ; Chizari, M ; Javad Mortazavi, S. M ; Rouhi, G ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Although the anterior cruciate ligament (ACL) reconstruction using interference screw is a well-accepted surgical procedure, patients still suffer graft failure in the initial rehabilitation phase. Graft fixation stability of a newly designed anatomical hybrid thread tapered interference screw (AHTTIS) was compared with a conventional standard one (CSIS) by conducting in-vitro mechanical tests. According to the CSIS manufacturer's instruction, eight tapered bone tunnels, matching AHTTIS geometry, and eight straight cylindrical tunnels were drilled in artificial bone blocks. Bovine tendon grafts were fixed using AHTTIS and CSIS in their corresponding bone tunnels. Each graft was subjected to...