    A robust short-circuit fault diagnosis for high voltage DC power supply based on multisensor data fusion

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; 2019 , Pages 659-664 ; 9781538692547 (ISBN) Ayoubi, R ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Short-circuit fault (SCF) detection is mandatory in a high voltage DC power supply (HVPS) to prevent fatal damage. The majority of converters employ a single sensor to detect the SCF. This attribute increases the interference vulnerability of the fault detection (FD) system in the presence of noise. Therefore, miss detections and false alarms are possible to occur. Miss detections and false alarms are harmful catastrophes in most applications. A commonly used method to suppress the noise impacts is using a low-bandwidth low-pass filter. However, the use of the low-bandwidth low-pass filter reduces the speed of FD due to the filter delay. This paper proposes a fast FD algorithm based on... 

    A fault-tolerant strategy for three-phase dual active bridge converter

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; 2019 , Pages 253-258 ; 9781538692547 (ISBN) Davoodi, A ; Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Due to several advantages, three-phase Dual Active Bridge (DAB) converter is widely used in numerous applications nowadays. On the other hand, this converter is very vulnerable to Transistor Open-Circuit Fault (TOCF). Therefore, a fault-tolerant (FT) scheme has been proposed in this paper to solve the problem. First, normal and faulty conditions are investigated, and according to the results, a fault-diagnosis (FD) approach is introduced. Using the outcomes of FD unit, a new post-fault strategy is proposed for the converter. The FD method is based on the DC component of transformer phase currents, and the basis of FT technique is shedding the faulty phase. Some benefits of the proposed... 

    Twin growth in RF window ceramic as a criterion for the response time of protection system in high power vacuum tubes

    , Article 2019 International Vacuum Electronics Conference, IVEC 2019, 28 April 2019 through 1 May 2019 ; 2019 ; 9781538675342 (ISBN) Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The ceramic fracture in output RF window is one of the most important failure factors in high power microwave sources. Fast protection systems are used to protect the source. The methods for determining the required protection response time are conservative and rough. In this paper, an investigation is presented about the twin growth in the ceramic of RF window in faulty condition. It is shown that the twin growth in ceramic can be a reliable figure of merit for the response time calculation of the microwave source protection system  

    A Vacuum arc diagnosis method for the high voltage power supply of vacuum tubes

    , Article 2019 International Vacuum Electronics Conference, IVEC 2019, 28 April 2019 through 1 May 2019 ; 2019 ; 9781538675342 (ISBN) Ayoubi, R ; Rahmanian, M ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Vacuum tubes are widely used for various applications. These vacuum tubes are supplied by high voltage power supplies. The amount of delivered energy from the high voltage power supply to the vacuum tube is an important issue during the vacuum arc in the tube. The protection mechanism consists of a shunt crowbar which diverts the fault current from the tube to itself as a parallel path. Detection of the vacuum arc is crucial and only one sensor is usually employed to detect the vacuum arc. This characteristic intensifies the interference susceptibility of the vacuum arc diagnosis system in a noisy environment. As a result of the noise, the arc detection system can report false alarms. False... 

    A Fast vacuum arc detection method based on the neural network data fusion algorithm for the high-voltage dc power supply of vacuum tubes

    , Article IEEE Transactions on Plasma Science ; 2020 Ayoubi, R ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    Vacuum arc is one of the most important failure factors of the vacuum tubes. The amount of delivered energy from the high-voltage dc power supply to the vacuum tube is an important issue during the vacuum arc in the tube. Vacuum arc acts as a short-circuit fault (SCF) at the power supply output. The majority of converters use a single current sensor to measure only the converter output current for detecting the SCF. However, the sensor may provide unreliable data because of the noise effect. Application of a low-pass filter reduces the noise effect. Regarding the delay of the low-pass filter, the interval of arc detection increases and more energy is delivered to the tube. In this article, a... 

    Flooding and dehydration diagnosis in a polymer electrolyte membrane fuel cell stack using an experimental adaptive neuro-fuzzy inference system

    , Article International Journal of Hydrogen Energy ; Volume 47, Issue 81 , 2022 , Pages 34628-34639 ; 03603199 (ISSN) Khanafari, A ; Alasty, A ; Kermani, M. J ; Asghari, S ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Today the need for fault diagnosis in polymer electrolyte membrane fuel cells (PEMFCs) is felt more than ever to increase the useful life and durability of the cell. The present study proposes an indirect in-situ experimental-based algorithm for diagnosing the moisture content issues in a three-cell stack. Three adaptive neuro-fuzzy inference systems (ANFIS) approximate the system outputs (cells voltages, cathodic and anodic pressure drop) in normal conditions. The values of Pearson's correlation coefficients (0.998, 0.983, and 0.995 for outputs, respectively) show the high quality of the modeling. In unknown operating conditions, the residuals of experimental and ANFIS values are compared... 

    Transmission grid fault diagnosis by wide area measurement system

    , Article IEEE PES Innovative Smart Grid Technologies Conference Europe ; 2012 ; 9781467325974 (ISBN) Salehi Dobakhshari, A ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    While the importance of wide area measurement system (WAMS) consisting of phasor measurement units (PMUs) is recognized, there are still unidentified applications that can be addressed with the advance of technology. Traditionally, power system operators diagnosed the fault point through the status of protective relays and circuit breakers of the protection system. In large blackouts, however, the malfunction of protection system has itself often been among the suspects of the disaster. This paper proposes an alternative fault diagnosis approach independent of the function of protection system, utilizing PMU data and bus impedance matrix (Zbus). First, the proposed method diagnoses the fault... 

    A decision tree-based method for power system fault diagnosis by synchronized Phasor Measurements

    , Article IEEE PES Innovative Smart Grid Technologies Conference Europe ; 2012 ; 9781467325974 (ISBN) Dehkordi, P. Z ; Dobakhshari, A. S ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    This paper introduces a novel approach for power system fault diagnosis based on synchronized phasor measurements during the fault. The synchronized measurements are obtained in real time from Phasor Measurement Units (PMUs) and compared with offline thresholds determined by decision trees (DTs) to diagnose the fault. The DTs have already been trained offline using detailed power system analysis for different fault cases. While the traditional methods for fault diagnosis use the status of protective relays (PRs) and circuit breakers (CBs) to infer the fault section in the power system, the proposed method uses the available signals following the fault and thus can be trusted even in case of... 

    Detection of inappropriate working conditions for the timing belt in internal-combustion engines using vibration signals and data mining

    , Article Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering ; Volume 231, Issue 3 , 2017 , Pages 418-432 ; 09544070 (ISSN) Khazaee, M ; Banakar, A ; Ghobadian, B ; Agha Mirsalim, M ; Minaei, S ; Jafari, S. M ; Sharif University of Technology
    SAGE Publications Ltd  2017
    Abstract
    Abnormal operating conditions for the timing belt can lead to cracks, fatigue, sudden rupture and damage to engines. In this study, an intelligent system was developed to detect and classify high-load operating conditions and high-temperature operating conditions for timing belts. To achieve this, vibration signals in normal operating conditions, high-load operating conditions and high-temperature operating conditions were collected. Time-domain signals were transformed to the frequency domain and the time-frequency domain using the fast Fourier transform method and the wavelet transform method respectively. In the data-mining stage, 25 statistical features were extracted from different...