Loading...
Search for: humidity-control
0.007 seconds
Total 29 records

    Thermal performance assessment of an evaporative condenser-based combined heat pump and humidification-dehumidification desalination system

    , Article Desalination ; Volume 496 , 2020 Faegh, M ; Shafii, M. B ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    A new design for heat pump integrated humidification-dehumidification (HDH-HP) desalination cycles was proposed in the current experimental study. An evaporative condenser was designed and fabricated instead of a separate humidifier, heater, and air/water-cooled condensers find in previous HDH-HP systems. Meanwhile, the air dehumidification process in this work directly occurred inside the heat pump evaporator. The effect of several operating parameters such as ambient wet-bulb temperature, spraying saline water and airflow rates, compressor speed, superheat, and evaporator saturation temperature control modes of the electronic expansion valve (EEV) on freshwater production and GOR were... 

    Supersonic separator's dehumidification performance with specific structure: Experimental and numerical investigation

    , Article Applied Thermal Engineering ; Volume 179 , October , 2020 Majidi, D ; Farhadi, F ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    Supersonic separators are used in gas separation processes such as dehumidification of humid air due to high performance and its good pressure recovery. In the present study, a comprehensive numerical and experimental investigation on the hydrodynamic behavior of air as working fluid and dehumidification performance of supersonic separator have been accomplished. The effect of the operational parameters on shockwave's position are examined. The outcomes show that by increasing the pressure level of supersonic separator, relative error between numerical and experimental results decreases from 20% to less than 10%. The effect of the operational parameters and humidity of inlet air on the... 

    Study of early-age creep and shrinkage of concrete containing Iranian pozzolans: An experimental comparative study

    , Article Scientia Iranica ; Volume 16, Issue 2 A , 2009 , Pages 126-137 ; 10263098 (ISSN) Ghodousi, P ; Afshar, M. H ; Ketabchi, H ; Rasa, E ; Sharif University of Technology
    2009
    Abstract
    This paper presents an experimental study on prediction of the early-age creep and shrinkage of concrete with and without silica fumes, trass, ground-granulated blast-furnace slag, combinations thereof, and influences of the proposed Iranian pozzolans. Experiments were carried out under a controlled ambient condition at a temperature of 40° C and a relative humidity (RH) of 50%, and a laboratory ambient condition at a temperature of 20° C and a relative humidity (RH) of 30% in order to collect the required data. Comparisons are made between ACI209-92, BS8110-1986 and CEB1970 prediction models, and an estimation model, based on 28-day results (short-term test method), using the same... 

    Sb2S3 and Cu3SbS4 nanocrystals as inorganic hole transporting materials in perovskite solar cells

    , Article Solar Energy ; Volume 223 , 2021 , Pages 106-112 ; 0038092X (ISSN) Mohamadkhani, F ; Heidariramsheh, M ; Javadpour, S ; Ghavaminia, E ; Mahdavi, S. M ; Taghavinia, N ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    One of the key parts of perovskite solar cells which has great influence on their performance and stability is hole transporting layer. Spiro-OMeTAD is extensively used as organic hole transporting material in perovskite solar cells. However, Spiro-OMeTAD is expensive and has low chemical stability. In this study, the solution processed Sb2S3 and Cu3SbS4 nanocrystals have been synthesized and then the n-i-p mesoscopic perovskite solar cells have been fabricated using Spiro-OMeTAD, Sb2S3 and Cu3SbS4 nanocrystals as hole transporting layer at ambient air condition. It is shown that the conduction and valence band levels of the synthesized Sb2S3 and Cu3SbS4 nanocrystals are in the proper... 

    Robust and efficient zero liquid discharge design strategy using four novel desalination systems: A comprehensive 4E assessment

    , Article Journal of Cleaner Production ; Volume 310 , 2021 ; 09596526 (ISSN) Ghofrani, I ; Moosavi, A ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    Discharging unconventional water sources having a high content of inorganic compounds is extremely destructive to the environment. In this research, four novel semi-open-air and closed-air configurations of brine-recycle humidification-dehumidification (BRHDH) systems with zero liquid discharge (ZLD) approach are presented to treat unconventional waters cost-effectively. Bubble-column humidifiers and dehumidifiers are used to have a low initial expenditure, and system multi-staging is implemented to reduce the operating expense of the configurations. The configurations are evaluated for high saline brine treatment using comprehensive energy, exergy, exergoeconomic, and exergoenvironmental... 

    Polyamide membrane surface and bulk modification using humid environment as a new heat curing medium

    , Article Journal of Membrane Science ; Volume 523 , 2017 , Pages 129-137 ; 03767388 (ISSN) Karimi, H ; Bazgar Bajestani, M ; Mousavi, S. A ; Mokhtari Garakani, R ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    Heat curing was devised in temperature-controlled steam and water environments to synthesize reverse osmosis (RO) polyamide (PA) membrane. The effect of new curing media on the physicochemical properties and RO performance of the synthesized polyamides was fully investigated using X-ray photoelectron spectroscopy (XPS), attenuated total reflection infrared (ATR-IR), scanning electron microscopy (SEM), atomic force microscopy (AFM), and water drop contact angle. The results show a reduction in amide linkage content on the surface of the steam-cured polyamide and surface and bulk of the water-cured polyamide. Additionally, it was revealed that heat curing in the humidity-controlled environment... 

    PID-Fuzzy control of air handling units in the presence of uncertainty

    , Article International Journal of Thermal Sciences ; Volume 109 , 2016 , Pages 123-135 ; 12900729 (ISSN) Moradi, H ; Setayesh, H ; Alasty, A ; Sharif University of Technology
    Elsevier Masson SAS 
    Abstract
    Air-handling unit (AHU) is one of the most complex installations that its control is necessary for maintaining satisfactory comfort conditions in buildings with low energy utilization. In this paper, a multivariable nonlinear and minimum phase model of the AHU is considered in the presence of uncertainties. The controller design is divided into two types. The first controller type is for the linearized plant based on decoupled PID-Fuzzy and PD-type Fuzzy controllers. The second type is based on full matrix PID-Fuzzy and pole-placement controllers in which interaction effects are considered. The indoor temperature and relative humidity are controlled via manipulation of valve positions of air... 

    Performance evaluation of different configurations of solar humidification-dehumidification desalination system with subsurface condenser

    , Article Energy Conversion and Management ; Volume 269 , 2022 ; 01968904 (ISSN) Asgari, B ; Bizhani, M ; Hakkaki Fard, A ; Kazemzadeh Hannani, S ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    The solar humidification-dehumidification desalination system with a subsurface condenser is a promising renewable energy-based desalination system. This desalination system is particularly suitable for condensation irrigation in greenhouses, especially where conventional energy sources are limited. A computational model of the system comprising a horizontal solar film evaporator and a subsurface condenser is developed. A previously proposed hybrid analytical–numerical model for horizontal ground heat exchangers is modified for the subsurface condenser. An experimental setup of the subsurface condenser is also built and used to verify the developed model of the subsurface condenser. The... 

    Performance evaluation of a novel compact humidification-dehumidification desalination system coupled with a heat pump for design and off-design conditions

    , Article Energy Conversion and Management ; Volume 194 , 2019 , Pages 160-172 ; 01968904 (ISSN) Faegh, M ; Shafii, M. B ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    In this study, the theoretical investigation of a novel heat pump assisted humidification-dehumidification desalination system has been carried out. The conventional dehumidifier of the humidification-dehumidification system was removed and the evaporator of the heat pump was utilized for direct dehumidification of air. Besides, the heat pump condenser was used as the saline water heater of the humidification-dehumidification cycle. First, the sizes of the components were calculated at design conditions for fixed input operational conditions namely the ambient air temperature, relative humidity, and inlet saline water temperature. However, the input operating conditions vary at off-design... 

    Performance enhancement of waste heat extraction from generator of a wind turbine for freshwater production via employing various nanofluids

    , Article Desalination ; Volume 478 , 2020 Rostamzadeh, H ; Rostami, S ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Water shortage issues are growing through the globe at higher rate than population growth. On the bright side, various methods are devised to capture energy from renewable energy or waste heat from different sectors. Among all inspected approaches, waste heat capturing through cooling process of the wind turbines' generators for desalination at small scale is paid less attention. However, in large wind farms, the scale of this dissipated thermal heat becomes appreciable which can drive several desalination units. Due to the above-pointed facts, the waste heat of a wind turbine with nominal capacity of 7358 kW and height of 24 m for desalinating seawater is inspected here, using a... 

    Nonlinear robust control of air handling units to improve the indoor air quality & CO2 concentration: A comparison between H∞ & decoupled sliding mode controls

    , Article Applied Thermal Engineering ; Volume 160 , 2019 ; 13594311 (ISSN) Setayesh, H ; Moradi, H ; Alasty, A ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Air-handling units (AHUs) are the installations responsible for the control of temperature and humidity inside a space using the heating, cooling, humidifier and drying air components. In this research, a multivariable nonlinear dynamic model of the AHU with one zone in the VAV (variable air volume) system for working in the summer is considered. The indoor temperature, relative humidity and carbon dioxide concentration are controlled via manipulation of the valve positions of the air flow rate, cold water flow rate and fresh air percent. Due to the complexity and nonlinearity of AHU model and also the existence of various operating points and uncertainty, model uncertainties are included.... 

    Metal-organic frameworks (MOF) based heat transfer: A comprehensive review

    , Article Chemical Engineering Journal ; Volume 449 , 2022 ; 13858947 (ISSN) Moayed Mohseni, M ; Jouyandeh, M ; Mohammad Sajadi, S ; Hejna, A ; Habibzadeh, S ; Mohaddespour, A ; Rabiee, N ; Daneshgar, H ; Akhavan, O ; Asadnia, M ; Rabiee, M ; Ramakrishna, S ; Luque, R ; Reza Saeb, M ; Sharif University of Technology
    Elsevier B.V  2022
    Abstract
    Higher than a standard level, the humidity provides a suitable environment for the pathogenic microorganisms to grow and increases energy consumption for cooling, increasing greenhouse gas emissions. Desiccant air-conditioning (DAC) is an effective method to reduce humidity and energy simultaneously. Conventional desiccants are not suitable for use as a desiccant in building air conditioners, mainly because of high regeneration temperature and other issues such as limited equilibrium capacity and hydrothermal and cyclic instability. Metal-organic frameworks (MOFs) are a novel class of porous crystalline materials without the disadvantages of traditional desiccants. They benefit from a huge... 

    Indirect mechanical heat pump assisted humidification-dehumidification desalination systems

    , Article International Journal of Energy Research ; Volume 45, Issue 11 , 2021 , Pages 15892-15920 ; 0363907X (ISSN) Rostamzadeh, H ; Sharif University of Technology
    John Wiley and Sons Ltd  2021
    Abstract
    In this study, four new indirect heat pump assisted mechanical vapor compression humidification-dehumidification (HDH) systems are proposed and their superiorities over the reference system are demonstrated from thermodynamics and thermoeconomics viewpoints. The proposed models are configured based on an HDH unit and a simple cascade heat pump, an HDH unit and a heat pump with an ejector, an HDH unit and a cascade heat pump with an ejector, and an HDH unit and a vapor injection heat pump. Although employing a heat pump with cascade and ejector configurations improved gain-output-ratio (GOR) and specific power consumption (SPC) values in comparison with the base system, the performance... 

    Freshwater and cooling production via integration of an ethane ejector expander transcritical refrigeration cycle and a humidification-dehumidification unit

    , Article Desalination ; Volume 477 , 2020 Gholizadeh, T ; Vajdi, M ; Rostamzadeh, H ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Despite the fact that humidification-dehumidification (HDH) desalination systems can be driven by various renewable or waste heat energies, many of the available renewable technologies are expensive in some parts of the globe. Hence, proposing and developing high-efficient mechanical-based HDH units can be an encouraging alternative which is more highlighted in recent investigations. In pursuance of this objective, three innovative mechanical-driven HDH units are simulated and the results are compared with each other. The simulated hybrid desalination system consists of a HDH unit and an ethane ejector expander transcritical refrigeration cycle (ethane-EETRC). The simulated hybrid systems... 

    Experimental investigation of heat recovery in a humidification-dehumidification desalination system via a heat pump

    , Article Desalination ; Volume 437 , 2018 , Pages 81-88 ; 00119164 (ISSN) Shafii, M. B ; Jafargholi, H ; Faegh, M ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    A hybrid HDH desalination system integrated with a heat pump was experimentally studied. In this system, heat pump's heating was used to raise the temperature of the air entering the humidifier and its cooling effect was used for dehumidification of humid air and freshwater production. In other words, heat pump's condenser works as the heater of the HDH cycle and its evaporator works as the coolant for the dehumidifier of HDH cycle. The effects of different parameters such as mass flow rate of inlet saline water (relative humidity of the air passing the dehumidification section), volume flow rate of the air passing the dehumidification section and ambient air temperature on freshwater... 

    Exergoeconomic optimization of a new trigeneration system driven by biogas for power, cooling, and freshwater production

    , Article Energy Conversion and Management ; Volume 205 , 2020 Gholizadeh, T ; Vajdi, M ; Rostamzadeh, H ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    Anaerobic fermentation of crop straw/animal dug can be the most appropriate solution for biomass conversion into applicable renewable energy-based fuels. However, due to the imperfection matching between the biogas combustion process and energy conversion system, a painstakingly design procedure is required to devise high-efficient energy system for capturing biogas efficiently. For this aim, a new trigeneration system driven by biogas is devised for electricity, refrigeration, and potable freshwater generation. The devised system encompasses a gas turbine (GT) cycle, a new cooling/electricity cogeneration system based on organic Rankine cycle (ORC) and ejector cooling cycle (ECC), and a... 

    Examination of a solar desalination system equipped with an air bubble column humidifier, evacuated tube collectors and thermosyphon heat pipes

    , Article Desalination ; Volume 397 , 2016 , Pages 30-37 ; 00119164 (ISSN) Behnam, P ; Behshad Shafii, M ; Sharif University of Technology
    Elsevier 
    Abstract
    In this paper, the performance of a novel HDH solar desalination system equipped with a combination of heat pipe (HP), evacuated tube collector (ETC) and air bubble column humidifier is experimentally investigated. This novel HDH system uses advantages of ETC-HP as a highly efficient thermal absorption and conductor device, and at the same time employs the advantages of an air bubble column humidifier, i.e. high interface area and effective mixing in order to heat the water and humidify the air, respectively. The effects of various parameters including incoming air flow rate into the humidifier, initial depth of water in the humidifier, and adding fluids such as oil and water in the space... 

    Energy, exergy, exergoeconomics, and exergoenvironmental assessment of three brine recycle humidification-dehumidification desalination systems applicable for industrial wastewater treatment

    , Article Energy Conversion and Management ; Volume 205 , 2020 Ghofrani, I ; Moosavi, A ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    Using zero liquid discharge systems is one of the efficient methods to reduce the negative environmental impact of the brines of the desalination systems and also to recycle the industrial wastewaters for reuse. Due to the simple fabrication process, low maintenance cost, intensive to inlet water quality, and the ability to use renewable and low-grade-heat, modified humidification-dehumidification systems may be a proper choice for the zero liquid discharge applications. Thus, in the present study, the energy, exergy, exergoeconomic, and exergoenvironmental assessment of three advanced brine recycle humidification-dehumidification systems for zero liquid discharge operation are... 

    Effect of CsCl additive on the morphological and optoelectronic properties of formamidinium lead iodide perovskite

    , Article Solar RRL ; Volume 3, Issue 11 , 2019 ; 2367198X (ISSN) Chavan, R. D ; Prochowicz, D ; Yadav, P ; Tavakoli, M. M ; Nimbalkar, A ; Bhoite, S. P ; Hong, C. K ; Sharif University of Technology
    Wiley-VCH Verlag  2019
    Abstract
    The quality of perovskite films plays a crucial role in improving the optoelectronic properties and performance of perovskite solar cells (PSCs). Herein, high-quality CsxFA1−xPbI3 perovskite films with different compositions (x = 0, 5, 10, and 15) are achieved by controlling the amount of cesium chloride (CsCl) in the respective FAPbI3 precursor solution. The effects of CsCl addition on the morphological and optoelectronic properties of the resulting perovskite films and on the performance of the corresponding devices are systematically studied. Introduction of CsCl into FAPbI3 shows a great potential to stabilize the α-FAPbI3 perovskite phase by forming CsxFA1−xPbI3 films with improved... 

    Development of artificial neural networks for performance prediction of a heat pump assisted humidification-dehumidification desalination system

    , Article Desalination ; Volume 508 , 2021 ; 00119164 (ISSN) Faegh, M ; Behnam, P ; Shafii, M. B ; Khiadani, M ; Sharif University of Technology
    Elsevier B.V  2021
    Abstract
    In this study, the application of data-driven methods for performance prediction of a heat pump assisted humidification-dehumidification (HDH-HP) desalination system was investigated for the first time. Although HDH-HP desalination systems have been widely studied both theoretically and experimentally, the application of data-driven models as a powerful predictive tool has not yet been investigated in these systems. To fill this gap, three data-driven models (MLPANN, RBFANN, and ANFIS) were applied using 180 experimental samples. The gain output ratio (GOR), heat transfer rates of the evaporator Q̇e, and evaporative condenser Q̇c, were considered as outputs. The results indicate that the...