Loading...
Search for: relative-standard-deviations
0.007 seconds
Total 52 records

    Gradient extractive phase prepared by controlled rate infusion method: An applicable approach in solid phase microextraction for non–targeted analysis

    , Article Journal of Chromatography A ; Volume 1574 , 2018 , Pages 130-135 ; 00219673 (ISSN) Enteshari Najafabadi, M ; Kazemi, E ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    The aim of this study is to introduce an extractive phase based on gradient concept by continuous changing in chemical functional groups for non–targeted analysis. For this purpose, three different two–component coatings containing (3–aminopropyl)trimethoxysilane (APTES) as polar and either phenyltriethoxysilane (PTES), octyl–trimethoxysilane (OTMS) or methyltrimethoxysilane (MTMS) as nonpolar precursors were formed on the modified stainless steel wires using controlled rate infusion (CRI) method. The presence of polar and/or non–polar functional groups on the surface of substrate was evaluated by Fourier–transform infrared spectroscopy (FTIR) together with contact angles determined... 

    Porous eco–friendly fibers for on–line micro solid–phase extraction of nonsteroidal anti–inflammatory drugs from urine and plasma samples

    , Article Journal of Chromatography A ; Volume 1574 , 2018 , Pages 18-26 ; 00219673 (ISSN) Golzari Aqda, T ; Behkami, S ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    In this study, cellulose acetate (CA) fibers were prepared using different solvent systems in electrospinning. The recorded scanning electron microscopy micrographs indicated that the morphology of the prepared fibers is closely associated with the type of electrospinning solvents. The prepared CA fibers were used as an extractive phase for on–line micro–solid phase extraction (μ-SPE) of nonsteroidal–inflammatory drugs (NSAIDs) in biological samples pursued by HPLC–UV determination. Work conducted on this research ascertained that the use of dichloromethane:acetone (3:1, v/v) solvent system in the CA dissolution for electrospinning, leads to the formation of porous ribbon–like fibers and... 

    Optimization of some experimental parameters in the electro membrane extraction of chlorophenols from seawater

    , Article Journal of Chromatography A ; Volume 1216, Issue 45 , 2009 , Pages 7687-7693 ; 00219673 (ISSN) Lee, J ; Khalilian, F ; Bagheri, H ; Lee, H. K ; Sharif University of Technology
    2009
    Abstract
    An electro membrane extraction (EME) methodology was utilized to study the isolation of some environmentally important pollutants, such as chlorophenols, from aquatic media based upon the electrokinetic migration process. The analytes were transported by application of an electrical potential difference over a supported liquid membrane (SLM). A driving force of 10 V was applied to extract the analytes through 1-octanol, used as the SLM, into a strongly alkaline solution. The alkaline acceptor solution was subsequently analyzed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The parameters influencing electromigration, including volumes and pH of the donor and... 

    Immersed single-drop microextraction-electrothermal vaporization atomic absorption spectroscopy for the trace determination of mercury in water samples

    , Article Journal of Hazardous Materials ; Volume 165, Issue 1-3 , 2009 , Pages 353-358 ; 03043894 (ISSN) Bagheri, H ; Naderi, M ; Sharif University of Technology
    2009

    Amine modified magnetic polystyrene for extraction of drugs from urine samples

    , Article Journal of Chromatography A ; Volume 1602 , 2019 , Pages 107-116 ; 00219673 (ISSN) Zeinali, S ; Maleki, M ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    Polystyrene is one of the best candidates as the extracting medium due to its high stability in different media and acceptable extraction capability. However, the hydrophobic nature and low wettability of polystyrene limits its application to non–polar analytes. To resolve this limitation, in this project, amine groups were chemically attached to the surface of magnetic polystyrene. The resulting hydrophilic magnetic particles were expected to be capable of extracting both polar and non–polar analytes. Non–steroidal anti–inflammatory drugs (NSAIDs) were chosen for testing the applicability of modified magnetic polystyrene according to the importance of their analysis and also their wide... 

    Graphene oxide-starch-based micro-solid phase extraction of antibiotic residues from milk samples

    , Article Journal of Chromatography A ; Volume 1591 , 2019 , Pages 7-14 ; 00219673 (ISSN) Golzari Aqda, T ; Behkami, S ; Raoofi, M ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    In this study, a method was described for the extraction of three antibiotic residues from cow milk samples using a graphene oxide–starch–based nanocomposite. The prepared nanocomposites were employed as an extractive phase for micro-solid phase extraction of antibiotics from cow milk samples. The extracted antibiotics, i.e. amoxicillin, ampicillin and cloxacillin, were subsequently analyzed by high-performance liquid chromatography–ultraviolet detection (HPLC–UV). Important variables associated with the extraction and desorption efficiency were optimized. High extraction efficiencies for the selected antibiotics were conveniently achieved using the starch–based nanocomposite as the... 

    Design of a pseudo stir bar sorptive extraction using graphenized pencil lead as the base of the molecularly imprinted polymer for extraction of nabumetone

    , Article Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy ; Volume 238 , 2020 Afsharipour, R ; Dadfarnia, S ; Haji Shabani, A. M ; Kazemi, E ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Molecularly imprinted polymer (MIP) was synthesized through the coprecipitation method on the graphene oxide anchored pencil lead as a substrate for the first time and applied as an efficient sorbent for pseudo stir bar sorptive extraction of nabumetone. The extracted analyte was determined by a novel spectrophotometric method based on the aggregation of silicate sol-gel stabilized silver nanoparticles in the presence of the analyte. The synthesized polymer was characterized using Fourier transform infrared spectroscopy and field emission scanning electron microscopy. Optimization of important parameters affecting the extraction efficiency was done using central composite design whereas the... 

    Super-porous semi-interpenetrating polymeric composite prepared in straw for micro solid phase extraction of antibiotics from honey, urine and wastewater

    , Article Journal of Chromatography A ; Volume 1631 , 2020 Asgari, S ; Bagheri, H ; Es-haghi, A ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    A cryogel–based semi–interpenetrating polymer network (Cryo–SIPN) was prepared in which conductive polymers such as polyaniline (PANI) and polypyrrole (PPy) were formed within the super porous network of acrylic acid cryogel. For completion of cryo-polymerization, all the constituent solutions were severely mixed and placed into the plastic straws and kept at -20°C and then the synthesized cyrogels were cut into the 1-cm length and freeze dried after washing with water. The Cryo–SIPN polymeric composite was applied in micro solid phase extraction (µSPE) of some selected antibiotic residues from various samples. The µSPE method combined with a high performance liquid... 

    Roles of metal, ligand and post synthetic modification on metal organic frameworks to extend their hydrophobicity and applicability toward ultra–trace determination of priority organic pollutants

    , Article Analytica Chimica Acta ; Volume 1125 , 2020 , Pages 231-246 Javanmardi, H ; Abbasi, A ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Implementation of metal organic frameworks (MOFs) in the separation science has attracted many researchers attention. In this study, the role of metal, ligand, the reaction condition and modification on the extraction efficiency of some MOFs was investigated. Among the prevalent reported MOFs, some members of the MIL and MOF–5 families were chosen, and eleven MOF–based sorbents were prepared by changing the metal and ligand type, reaction condition, and/or functionality through post synthetic modification (PSM). MIL–101 and MIL–101–NH2 based structures were initially synthesized based on the chromium and iron salts. Also, three zinc–based structures including MOF–5, [NH2(CH3)2]2... 

    The geometrical characteristics of nickel-based metal organic framework on its entrapment capability

    , Article Journal of Chromatography A ; Volume 1610 , 2020 Javanmardi, H ; Abbasi, A ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Here, a three dimensional nickel–based metal organic framework (MOF) was synthesized via solvothermal and room temperature protocols. In order to study the effects of the synthesis conditions on the physical properties such as pore sizes and shapes of the prepared MOFs, their extraction capabilities were examined. Both MOFs were characterized by Fourier transform infrared spectroscopy, powder X-ray diffraction, scanning electron microscopy, Brunauer–Emmett–Teller and thermogravimetric analyses. Brilliant properties such as porous structure, high surface area and considerable thermal stability make them reasonable candidates to be employed as efficient extractive phases. The efficiency of the... 

    Sensitive voltammetric detection of melatonin in pharmaceutical products by highly conductive porous graphene-gold composites

    , Article ACS Sustainable Chemistry and Engineering ; 2020 Rahmati, R ; Hemmati, A ; Mohammadi, R ; Hatamie, A ; Tamjid, E ; Simchi, A ; Sharif University of Technology
    American Chemical Society  2020
    Abstract
    This work presents a novel melatonin sensor based on unfunctionalized macroporous graphene networks decorated with gold nanoparticles for the differential pulse voltammetric detection of melatonin in pharmaceutical products. Highly porous graphene structures were prepared by metallic template-assisted chemical vapor deposition, and their active surface area and electrocatalytic activity were improved by electrochemical deposition of gold nanoparticles (50-250 nm) on their struts. The graphene-gold electrodes present a highly sensitive performance toward electro-oxidation of melatonin with a wide linear range of 0.05-50 μM, a low detection limit of 0.0082 μM (3σ/m), and a significant... 

    Analysis of alternative new pesticide (fluopyram, flupyradifurone, and indaziflam) residues in pistachio, date, and soil by liquid chromatography triple quadrupole tandem mass spectrometry

    , Article Soil and Sediment Contamination ; Volume 30, Issue 4 , 2021 , Pages 373-383 ; 15320383 (ISSN) Mahdavi, V ; Keikavousi Behbahan, A ; Moradi, F ; Aboul Enein, H. Y ; Sharif University of Technology
    Bellwether Publishing, Ltd  2021
    Abstract
    Fluopyram, flupyradifurone, and indaziflam are novel systemic pesticides developed by Bayer. Based on available data, these pesticides appears to have a favorable safety profile in the case of pesticide residue problems. Herein, we report an effective analytical method for the determination of novel pesticides were developed using ultra-high performance liquid chromatography with tandem mass spectrometry coupled with a quick, easy, cheap, effective, rugged, and safe procedure. These target compounds were extracted with acetonitrile and cleaned up with PSA, and were separated successfully between 10.2 and 18.3 min using a C18 chromatographic column connected to an electrospray ionization...