Loading...
Search for: biological-model
0.011 seconds
Total 110 records

    Phenomenological tissue fracture modeling for an Endoscopic Sinus and Skull Base Surgery training system based on experimental data

    , Article Medical Engineering and Physics ; Volume 68 , 2019 , Pages 85-93 ; 13504533 (ISSN) Sadeghnejad, S ; Farahmand, F ; Vossoughi, G ; Moradi, H ; Mousa Sadr Hosseini, S ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    The ideal simulator for Endoscopic Sinus and Skull Base Surgery (ESSS)training must be supported by a physical model and provide repetitive behavior in a controlled environment. Development of realistic tissue models is a key part of ESSS virtual reality (VR)-based surgical simulation. Considerable research has been conducted to address haptic or force feedback and propose a phenomenological tissue fracture model for sino-nasal tissue during surgical tool indentation. Mechanical properties of specific sino-nasal regions of the sheep head have been studied in various indentation and relaxation experiments. Tool insertion at different indentation rates into coronal orbital floor (COF)tissue is... 

    A novel nonlinear function evaluation approach for efficient fpga mapping of neuron and synaptic plasticity models

    , Article IEEE Transactions on Biomedical Circuits and Systems ; Volume 13, Issue 2 , 2019 , Pages 454-469 ; 19324545 (ISSN) Jokar, E ; Abolfathi, H ; Ahmadi, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Efficient hardware realization of spiking neural networks is of great significance in a wide variety of applications, such as high-speed modeling and simulation of large-scale neural systems. Exploiting the key features of FPGAS, this paper presents a novel nonlinear function evaluation approach, based on an effective uniform piecewise linear segmentation method, to efficiently approximate the nonlinear terms of neuron and synaptic plasticity models targeting low-cost digital implementation. The proposed approach takes advantage of a high-speed and extremely simple segment address encoder unit regardless of the number of segments, and therefore is capable of accurately approximating a given... 

    A stability-based model of a growing spine with adolescent idiopathic scoliosis: A combination of musculoskeletal and finite element approaches

    , Article Medical Engineering and Physics ; Volume 64 , 2019 , Pages 46-55 ; 13504533 (ISSN) Kamal, Z ; Rouhi, G ; Arjmand, N ; Adeeb, S ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Using a combined musculoskeletal and finite element (FE) approach, this study aimed to evaluate stability-based muscle forces in a spine with adolescent idiopathic scoliosis (AIS) as compared to a normal spine; and subsequently, determine the effects of stress distribution on the growth plates (GPs) of the growing spine. For this purpose a nonlinear 3D FE model of one normal and one scoliotic thoracolumbar spine, consisting of GPs attached to rigid L1 to L4 vertebrae, were developed using computed tomography images coupled with a growth modulation using the Stokes’ model. Corresponding well with recent in-vivo and in-vitro studies, results of the models predicted intradiscal pressures at the... 

    A three-dimensional statistical volume element for histology informed micromechanical modeling of brain white matter

    , Article Annals of Biomedical Engineering ; Volume 48, Issue 4 , 2020 , Pages 1337-1353 Hoursan, H ; Farahmand, F ; Ahmadian, M. T ; Sharif University of Technology
    Springer  2020
    Abstract
    This study presents a novel statistical volume element (SVE) for micromechanical modeling of the white matter structures, with histology-informed randomized distribution of axonal tracts within the extracellular matrix. The model was constructed based on the probability distribution functions obtained from the results of diffusion tensor imaging as well as the histological observations of scanning electron micrograph, at two structures of white matter susceptible to traumatic brain injury, i.e. corpus callosum and corona radiata. A simplistic representative volume element (RVE) with symmetrical arrangement of fully alligned axonal fibers was also created as a reference for comparison. A... 

    Atheroprone sites of coronary artery bifurcation: Effect of heart motion on hemodynamics-dependent monocytes deposition

    , Article Computers in Biology and Medicine ; Volume 133 , 2021 ; 00104825 (ISSN) Biglarian, M ; Firoozabadi, B ; Saidi, M. S ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    Atherosclerosis as a common cardiovascular disease is a result of both adverse hemodynamics conditions and monocyte deposition within coronary arteries. It is known that the adhesion of monocytes on the arterial wall and their interaction with the vascular surface are one of the main parameters in the initiation and progression of atherosclerosis. In this work, hemodynamic parameters and monocyte deposition have been investigated in a 3D computational model of the Left Anterior Descending coronary artery (LAD) and its first diagonal branch (D1) under the heart motion. A one-way Lagrangian approach is performed to trace the monocyte particles under different blood flow regimes and heart motion... 

    Neuromuscular control of the point to point and oscillatory movements of a sagittal arm with the actor-critic reinforcement learning method

    , Article Computer Methods in Biomechanics and Biomedical Engineering ; Volume 8, Issue 2 , 2005 , Pages 103-113 ; 10255842 (ISSN) Golkhou, V ; Parnianpour, M ; Lucas, C ; Sharif University of Technology
    2005
    Abstract
    In this study, we have used a single link system with a pair of muscles that are excited with alpha and gamma signals to achieve both point to point and oscillatory movements with variable amplitude and frequency. The system is highly nonlinear in all its physical and physiological attributes. The major physiological characteristics of this system are simultaneous activation of a pair of nonlinear musclelike- actuators for control purposes, existence of nonlinear spindle-like sensors and Golgi tendon organlike sensor, actions of gravity and external loading. Transmission delays are included in the afferent and efferent neural paths to account for a more accurate representation of the reflex... 

    MaxHiC: A robust background correction model to identify biologically relevant chromatin interactions in Hi-C and capture Hi-C experiments

    , Article PLoS Computational Biology ; Volume 18, Issue 6 , 2022 ; 1553734X (ISSN) Alinejad Rokny, H ; Modegh, R. G ; Rabiee, H. R ; Sarbandi, E. R ; Rezaie, N ; Tam, K. T ; Forrest, A. R. R ; Sharif University of Technology
    Public Library of Science  2022
    Abstract
    Hi-C is a genome-wide chromosome conformation capture technology that detects interactions between pairs of genomic regions and exploits higher order chromatin structures. Conceptually Hi-C data counts interaction frequencies between every position in the genome and every other position. Biologically functional interactions are expected to occur more frequently than transient background and artefactual interactions. To identify biologically relevant interactions, several background models that take biases such as distance, GC content and mappability into account have been proposed. Here we introduce MaxHiC, a background correction tool that deals with these complex biases and robustly... 

    Modeling, simulation, and optimal initiation planning for needle insertion into the liver

    , Article Journal of Biomechanical Engineering ; Volume 132, Issue 4 , 2010 ; 01480731 (ISSN) Sharifi Sedeh, R ; Ahmadian, M. T ; Janabi Sharifi, F ; Sharif University of Technology
    2010
    Abstract
    Needle insertion simulation and planning systems (SPSs) will play an important role in diminishing inappropriate insertions into soft tissues and resultant complications. Difficulties in SPS development are due in large part to the computational requirements of the extensive calculations in finite element (FE) models of tissue. For clinical feasibility, the computational speed of SPSs must be improved. At the same time, a realistic model of tissue properties that reflects large and velocity-dependent deformations must be employed. The purpose of this study is to address the aforementioned difficulties by presenting a cost-effective SPS platform for needle insertions into the liver. The study... 

    Margination and adhesion of micro- and nanoparticles in the coronary circulation: A step towards optimised drug carrier design

    , Article Biomechanics and Modeling in Mechanobiology ; Volume 17, Issue 1 , 2018 , Pages 205-221 ; 16177959 (ISSN) Forouzandehmehr, M ; Shamloo, A ; Sharif University of Technology
    Springer Verlag  2018
    Abstract
    Obstruction of left anterior descending artery (LAD) due to the thrombosis or atherosclerotic plaques is the leading cause of death worldwide. Targeted delivery of drugs through micro- and nanoparticles is a very promising approach for developing new strategies in clot-busting or treating restenosis. In this work, we modelled the blood flow characteristics in a patient-specific reconstructed LAD artery by the fluid–solid interaction method and based on physiological boundary conditions. Next, we provided a Lagrangian description of micro- and nanoparticles dynamics in the blood flow considering their Brownian motion and the particle–particle interactions. Our results state that the number of... 

    A foreign body response-on-a-chip platform

    , Article Advanced Healthcare Materials ; Volume 8, Issue 4 , 2019 ; 21922640 (ISSN) Sharifi, F ; Htwe, S. S ; Righi, M ; Liu, H ; Pietralunga, A ; Yesil Celiktas, O ; Maharjan, S ; Cha, B. H ; Shin, S. R ; Dokmeci, M. R ; Vrana, N. E ; Ghaemmaghami, A. M ; Khademhosseini, A ; Zhang, Y. S ; Sharif University of Technology
    Wiley-VCH Verlag  2019
    Abstract
    Understanding the foreign body response (FBR) and desiging strategies to modulate such a response represent a grand challenge for implant devices and biomaterials. Here, the development of a microfluidic platform is reported, i.e., the FBR-on-a-chip (FBROC) for modeling the cascade of events during immune cell response to implants. The platform models the native implant microenvironment where the implants are interfaced directly with surrounding tissues, as well as vasculature with circulating immune cells. The study demonstrates that the release of cytokines such as monocyte chemoattractant protein 1 (MCP-1) from the extracellular matrix (ECM)-like hydrogels in the bottom tissue chamber...