Loading...
Search for: stress--mechanical
0.009 seconds
Total 30 records

    Search for critical loading condition of the spine-A meta analysis of a nonlinear viscoelastic finite element model

    , Article Computer Methods in Biomechanics and Biomedical Engineering ; Volume 8, Issue 5 , 2005 , Pages 323-330 ; 10255842 (ISSN) Wang, J. L ; Shirazi Adl, A ; Parnianpour, M ; Sharif University of Technology
    2005
    Abstract
    The relative vulnerability of spinal motion segments to different loading combinations remains unknown. The meta-analysis described here using the results of a validated L2-L3 nonlinear viscoelastic finite element model was designed to investigate the critical loading and its effect on the internal mechanics of the human lumbar spine. A Box-Behnken experimental design was used to design the magnitude of seven independent variables associated with loads, rotations and velocity of motion. Subsequently, an optimization method was used to find the primary and secondary variables that influence spine mechanical output related to facet forces, disc pressure, ligament forces, annulus matrix... 

    Tissue growth into three-dimensional composite scaffolds with controlled micro-features and nanotopographical surfaces

    , Article Journal of Biomedical Materials Research - Part A ; Volume 101, Issue 10 , 2013 , Pages 2796-2807 ; 15493296 (ISSN) Tamjid, E ; Simchi, A ; Dunlop, J. W. C ; Fratzl, P ; Bagheri, R ; Vossoughi, M ; Sharif University of Technology
    2013
    Abstract
    Controlling topographic features at all length scales is of great importance for the interaction of cells with tissue regenerative materials. We utilized an indirect three-dimensional printing method to fabricate polymeric scaffolds with pre-defined and controlled external and internal architecture that had an interconnected structure with macro- (400-500 μm) and micro- (∼25 μm) porosity. Polycaprolactone (PCL) was used as model system to study the kinetics of tissue growth within porous scaffolds. The surface of the scaffolds was decorated with TiO2 and bioactive glass (BG) nanoparticles to the better match to nanoarchitecture of extracellular matrix (ECM). Micrometric BG particles were... 

    A viscoelastic model for axonal microtubule rupture

    , Article Journal of Biomechanics ; Volume 48, Issue 7 , 2015 , Pages 1241-1247 ; 00219290 (ISSN) Shamloo, A ; Manuchehrfar, F ; Rafii Tabar, H ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    Axon is an important part of the neuronal cells and axonal microtubules are bundles in axons. In axons, microtubules are coated with microtubule-associated protein tau, a natively unfolded filamentous protein in the central nervous system. These proteins are responsible for cross-linking axonal microtubule bundles. Through complimentary dimerization with other tau proteins, bridges are formed between nearby microtubules creating bundles. Formation of bundles of microtubules causes their transverse reinforcement and has been shown to enhance their ability to bear compressive loads. Though microtubules are conventionally regarded as bearing compressive loads, in certain circumstances during... 

    Fluid–structure interaction simulation of a cerebral aneurysm: effects of endovascular coiling treatment and aneurysm wall thickening

    , Article Journal of the Mechanical Behavior of Biomedical Materials ; Volume 74 , 2017 , Pages 72-83 ; 17516161 (ISSN) Shamloo, A ; Nejad, M. A ; Saeedi, M ; Sharif University of Technology
    Abstract
    In the present study, we investigate the effect of the hemodynamic factors of the blood flow on the cerebral aneurysms. To this end, a hypothetical geometry of the aneurysm in the circle of Willis, located in the bifurcation point of the anterior cerebral artery (ACA) and anterior communicating artery (ACoA) is modeled in a three-dimensional manner. Three cases are chosen in the current study: an untreated thin wall (first case), untreated thick wall (second case), and a treated aneurysm (third case). The effect of increasing the aneurysm wall thickness on the deformation and stress distribution of the walls are studied. The obtained results showed that in the second case, a reduction in the... 

    A validation study of a virtual-based haptic system for endoscopic sinus surgery training

    , Article International Journal of Medical Robotics and Computer Assisted Surgery ; Volume 15, Issue 6 , 2019 ; 14785951 (ISSN) Sadeghnejad, S ; Khadivar, F ; Abdollahi, E ; Moradi, H ; Farahmand, F ; Sadr Hosseini, S. M ; Vossoughi, G ; Sharif University of Technology
    John Wiley and Sons Ltd  2019
    Abstract
    Background: The development of endoscopic sinus surgery (ESS) training simulators for clinical environment applications has reduced the existing shortcomings in conventional teaching methods, creating a standard environment for trainers and trainees in a more accurate and repeatable fashion. Materials and methods: In this research, the validation study of an ESS training simulator has been addressed. It is important to consider components that guide trainees to improve their hand movements control in the orbital floor removal in an ESS operation. Therefore, we defined three tasks to perform: pre-experiment learning, training, and evaluation. In these tasks, the critical regions introduced in... 

    A multi-objective approach to optimize the weight and stress of the locking plates using finite element modeling

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 236, Issue 2 , 2022 , Pages 188-198 ; 09544119 (ISSN) Rafiei, S ; Nourani, A ; Chizari, M ; Sharif University of Technology
    SAGE Publications Ltd  2022
    Abstract
    This paper aims to identify an optimum bone fracture stabilizer. For this purpose, three design variables including the ratio of the screw diameter to the plate width at three levels, the ratio of the plate thickness to the plate width at three levels, and the diameter of the bone at two levels were selected for analysis. Eighteen 3D verified finite element models were developed to examine the effects of these parameters on the weight, maximum displacement and maximum von Mises stress of the fixation structure. Considering the relations between the inputs and outputs using multivariate regression, a genetic algorithm was used to find the optimal choices. Results showed that the diameter of... 

    Properties of Nafion Under Uniaxial Loading at Different Temperatures: A Molecular Dynamics Study

    , Article Polymer - Plastics Technology and Engineering ; Volume 54, Issue 8 , 2015 , Pages 806-813 ; 03602559 (ISSN) Ozmaian, M ; Naghdabadi, R ; Sharif University of Technology
    Taylor and Francis Inc  2015
    Abstract
    Nafion membrane encounters many different thermal conditions and mechanical loadings because of its wide range of applications as a proton exchange membrane (PEM). Molecular dynamics simulation of hydrated Nafion at different temperatures is carried out to investigate the alteration of the physical properties of Nafion under uniaxial loading over a wide range of temperatures. According to the simulation results, increase of the temperature reduces the yield stress. The results also show that the polymer chains ordering increases the glass transition temperature and enhances the self-diffusion coefficient of water in hydrated Nafion. Comparisons show that the elastic modulus and viscosity... 

    A meta-model analysis of a finite element simulation for defining poroelastic properties of intervertebral discs

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 227, Issue 6 , 2013 , Pages 672-682 ; 09544119 (ISSN) Nikkhoo, M ; Hsu, Y. C ; Haghpanahi, M ; Parnianpour, M ; Wang, J. L ; Sharif University of Technology
    2013
    Abstract
    Finite element analysis is an effective tool to evaluate the material properties of living tissue. For an interactive optimization procedure, the finite element analysis usually needs many simulations to reach a reasonable solution. The metamodel analysis of finite element simulation can be used to reduce the computation of a structure with complex geometry or a material with composite constitutive equations. The intervertebral disc is a complex, heterogeneous, and hydrated porous structure. A poroelastic finite element model can be used to observe the fluid transferring, pressure deviation, and other properties within the disc. Defining reasonable poroelastic material properties of the... 

    An analytical approach to study the intraoperative fractures of femoral shaft during total hip arthroplasty

    , Article Journal of Biomechanical Engineering ; Volume 135, Issue 4 , 2013 ; 01480731 (ISSN) Malekmotiei, L ; Farahmand, F ; Shodja, H. M ; Samadi Dooki, A ; Sharif University of Technology
    2013
    Abstract
    An analytical approach which is popular in micromechanical studies has been extended to the solution for the interference fit problem of the femoral stem in cementless total hip arthroplasty (THA). The multiple inhomogeneity problem of THA in transverse plane, including an elliptical stem, a cortical wall, and a cancellous layer interface, was formulated using the equivalent inclusion method (EIM) to obtain the induced interference elastic fields. Results indicated a maximum interference fit of about 210 μm before bone fracture, predicted based on the Drucker-Prager criterion for a partially reamed section. The cancellous layer had a significant effect on reducing the hoop stresses in the... 

    Nanoindentation of isotactic polypropylene: Correlations between hardness, yield stress, and modulus on the local and global scales

    , Article Journal of Applied Polymer Science ; Volume 121, Issue 2 , February , 2011 , Pages 930-938 ; 00218995 (ISSN) Lesan Khosh, R ; Bagheri, R ; Asgari, S ; Sharif University of Technology
    2011
    Abstract
    The correlations between the hardness, yield stress, and modulus of elasticity of isotactic polypropylene (iPP) were evaluated on the local and global scales. Nanoindentation and traditional macromechanical tests were incorporated for this purpose. Thus, local and global mechanical properties were measured at various temperatures and strain rates. A certain relation was found between the local and global mechanical properties. Moreover, Johnson's model (developed according to the expanding cavity model) was also evaluated at various temperatures and strain rates. The Johnson model was valid only for the yield stresses obtained by nanoindentation and compressive tests and also the elastic... 

    Tool-tissue force estimation in laparoscopic surgery using geometric features

    , Article Studies in Health Technology and Informatics ; Volume 184 , 2013 , Pages 225-229 ; 09269630 (ISSN) Kohani, M ; Behzadipour, S ; Farahmand, F ; Sharif University of Technology
    IOS Press  2013
    Abstract
    This paper introduces three geometric features, from deformed shape of a soft tissue, which demonstrate good correlation with probing force and maximum local stress. Using FEM simulation, 2D and 3D model of an in vivo porcine liver was built for different probing tasks. Maximum deformation angle, maximum deformation depth and width of displacement constraint of the reconstructed shape of the deformed body were calculated. Two neural networks were trained from these features and the calculated interaction forces. The features are shown to have high potential to provide force estimation either for haptic devices or to assess the damage to the tissue in large deformations of up to 40%  

    Preparation and characteristics of epoxy/clay/B4C nanocomposite at high concentration of boron carbide for neutron shielding application

    , Article Radiation Physics and Chemistry ; Volume 141 , 2017 , Pages 223-228 ; 0969806X (ISSN) Kiani, M. A ; Ahmadi, S. J ; Outokesh, M ; Adeli, R ; Mohammadi, A ; Sharif University of Technology
    Abstract
    In this research, the characteristics of the prepared samples in epoxy matrix by means of X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), as well as scanning electron microscope (SEM) are evaluated. Meanwhile, the obtained mechanical properties of the specimen are investigated. Thermogravimetric analysis (TGA) is also employed to evaluate the thermal degradation of manufactured nanocomposites. The thermal neutron absorption properties of nanocomposites containing 3 wt% of montmorillonite nanoclay (closite30B) have been studied experimentally, using an Am-Be point source. Mechanical tests reveal that the higher B4C concentrations, the more tensile strengths, but lower... 

    Investigation of the effect of high +Gz accelerations on human cardiac function

    , Article Journal of the Mechanical Behavior of Biomedical Materials ; Volume 27 , 2013 , Pages 54-63 ; 17516161 (ISSN) Jamshidi, M ; Ahmadian, M. T ; Sharif University of Technology
    Abstract
    This study investigates the effect of body acceleration on human cardiac function. Finite element analysis is conducted to simulate geometrical and mechanical properties of human heart. Heart geometrical modeling in three-dimension is performed by segmentation of cardiac MRI images. The nonlinear mechanical behavior of myocardium is modeled by Mooney-Rivlin, Polynomial, Ogden and Yeoh hyperelastic material models. Stress-strain curves of myocardial tissue are obtained from experimental compression tests on bovine heart samples. The experimental results are employed for the evaluation of material coefficients by the nonlinear least squares method. Among hyperelastic models, the Yeoh model... 

    A rigid body spring model to investigate the lateral shift-Restraining force behavior of the patellar

    , Article 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07, Lyon, 23 August 2007 through 26 August 2007 ; 2007 , Pages 4679-4682 ; 05891019 (ISSN) ; 1424407885 (ISBN); 9781424407880 (ISBN) Jafari, A ; Farahmand, F ; Meghdari, A ; Sharif University of Technology
    2007
    Abstract
    Patellar lateral stability was studied using a 2D transverse plane model with deformable articular surfaces. Quadriceps muscles and patellar tendon were considered as strings with predefined forces and lateral and medial retinaculum as tensile springs. Deformation behavior of articular cartilage was modeled by a set of compression springs perpendicular to articular surfaces, based on rigid body spring model method (RBSM). Patellar lateral stability was investigated using restraining force method (the external force required to cause up to 10 mm lateral displacement on patella). The results were in good agreement with experimental reports for normal joint, vastus lateralis and vastus medialis... 

    A new approach to C2 continuous piecewise bicubic representation of the articular surfaces of diarthrodial joints

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 220, Issue 4 , 2006 , Pages 553-563 ; 09544119 (ISSN) Jafari, A ; Farahmand, F ; Meghdari, A ; Golestanha, A. S ; Sharif University of Technology
    2006
    Abstract
    Based on the force-deflection equation for a beam subjected to lateral point loads, a C2 continuous piecewise bicubic mathematical representation was proposed to model complicated geometrical surfaces, e.g. the articular surfaces of human joints. The method was then extended so that it could be used for mathematical modelling of incomplete nets of data points, as well as smoothing of noisy and/or filtering of erroneous data points. Mathematical techniques were also developed to calculate the required unknown parameters explicitly, with no need to solve the system of equations simultaneously. The performance of the proposed method was evaluated on a number of surface modelling problems,... 

    A three-dimensional statistical volume element for histology informed micromechanical modeling of brain white matter

    , Article Annals of Biomedical Engineering ; Volume 48, Issue 4 , 2020 , Pages 1337-1353 Hoursan, H ; Farahmand, F ; Ahmadian, M. T ; Sharif University of Technology
    Springer  2020
    Abstract
    This study presents a novel statistical volume element (SVE) for micromechanical modeling of the white matter structures, with histology-informed randomized distribution of axonal tracts within the extracellular matrix. The model was constructed based on the probability distribution functions obtained from the results of diffusion tensor imaging as well as the histological observations of scanning electron micrograph, at two structures of white matter susceptible to traumatic brain injury, i.e. corpus callosum and corona radiata. A simplistic representative volume element (RVE) with symmetrical arrangement of fully alligned axonal fibers was also created as a reference for comparison. A... 

    On the evolution of flow stress during constrained groove pressing of pure copper sheet

    , Article Computational Materials Science ; Volume 45, Issue 4 , 2009 , Pages 855-859 ; 09270256 (ISSN) Hosseini, E ; Kazeminezhad, M ; Mani, A ; Rafizadeh, E ; Sharif University of Technology
    2009
    Abstract
    Using a mechanical model and dislocation density based model, the evolutions of dislocation density and flow stress of pure copper during constrained groove pressing (CGP) process are investigated. In this regard, the strain and strain rate are achieved from the mechanical model and then input into the dislocation model. To verify the predicted flow stress, the process of constrained groove pressing is performed on the sheets of pure copper from one to three passes. The predicted flow stresses are compared with the experimental data and a good agreement is observed. Also, it is found that during the straining of the copper sheet in CGP process, the dislocation density and strength dropping... 

    Analysis of different material theories used in a FE model of a lumbar segment motion

    , Article Acta of Bioengineering and Biomechanics ; Volume 15, Issue 2 , 2013 , Pages 33-41 ; 1509409X (ISSN) Gohari, E ; Nikkhoo, M ; Haghpanahi, M ; Parnianpour, M ; Sharif University of Technology
    2013
    Abstract
    In this study, a nonlinear poroelastic model of intervertebral disc as an infrastructure was developed. Moreover, a new element was defined consisting a disc (Viscoelastic Euler Beam Element) and a vertebra (Rigid Link) as a unit element. Using the new element, three different viscoelastic finite element models were prepared for lumbar motion segment (L4/L5). Prolonged loading (short-term and long-term creep) and cyclic loading were applied to the models and the results were compared with results of in vivo tests. Simplification of the models by using the new element leads to reduction of the runtime of the models in dynamic analyses to few minutes without losing the accuracy in the results  

    An improved multi-joint EMG-assisted optimization approach to estimate joint and muscle forces in a musculoskeletal model of the lumbar spine

    , Article Journal of Biomechanics ; Volume 44, Issue 8 , 2011 , Pages 1521-1529 ; 00219290 (ISSN) Gagnon, D ; Arjmand, N ; Plamondon, A ; Shirazi Adl, A ; Larivière, C ; Sharif University of Technology
    Abstract
    Muscle force partitioning methods and musculoskeletal system simplifications are key modeling issues that can alter outcomes, and thus change conclusions and recommendations addressed to health and safety professionals. A critical modeling concern is the use of single-joint equilibrium to estimate muscle forces and joint loads in a multi-joint system, an unjustified simplification made by most lumbar spine biomechanical models. In the context of common occupational tasks, an EMG-assisted optimization method (EMGAO) is modified in this study to simultaneously account for the equilibrium at all lumbar joints (M-EMGAO). The results of this improved approach were compared to those of its... 

    Margination and adhesion of micro- and nanoparticles in the coronary circulation: A step towards optimised drug carrier design

    , Article Biomechanics and Modeling in Mechanobiology ; Volume 17, Issue 1 , 2018 , Pages 205-221 ; 16177959 (ISSN) Forouzandehmehr, M ; Shamloo, A ; Sharif University of Technology
    Springer Verlag  2018
    Abstract
    Obstruction of left anterior descending artery (LAD) due to the thrombosis or atherosclerotic plaques is the leading cause of death worldwide. Targeted delivery of drugs through micro- and nanoparticles is a very promising approach for developing new strategies in clot-busting or treating restenosis. In this work, we modelled the blood flow characteristics in a patient-specific reconstructed LAD artery by the fluid–solid interaction method and based on physiological boundary conditions. Next, we provided a Lagrangian description of micro- and nanoparticles dynamics in the blood flow considering their Brownian motion and the particle–particle interactions. Our results state that the number of...