    Electrochemical determination of atorvastatin on nano-scaled polypyrrole film

    , Article Bioelectrochemistry ; Vol. 98 , 2014 , pp. 1-10 ; ISSN: 15675394 Kamalzadeh, Z ; Shahrokhian, S ; Sharif University of Technology
    Abstract
    Pyrrole was electro-polymerized on the surface of the glassy carbon electrode (GCE) coated with a thin film of carbon nanomaterials, including carbon nanotubes (CNTs), carbon nanoparticles (CNPs), nanodiamond-graphite (NDG) or graphite nanopowder (GNP). Morphology, thickness, stability and loading of the polypyrrole (PPY) film were significantly affected by the structure and morphology of the sub-layer of carbon nanomaterials. Electrochemical oxidation of atorvastatin (ATOR) was investigated. Under the optimized conditions, a significant increase in the peak current (compared to other modified electrodes and bare GCE) and a negative shift in the peak potential (compared to bare GCE) were... 

    A comprehensive procedure for characterizing arbitrary azimuthally symmetric photon beams

    , Article Physica Medica ; Vol. 30, Issue. 2 , 2014 , Pages 191-201 ; ISSN: 11201797 Ezzati, A. O ; Sohrabpour, M ; Mahdavi, S. R ; Buzurovic, I ; Studenski, M. T ; Sharif University of Technology
    Abstract
    Purpose: A new Monte Carlo (MC) source model (SM) has been developed for azimuthally symmetric photon beams. Methods: The MC simulation tallied phase space file (PSF) is divided into two categories depending on the relationship of the particle track line to the beam central axis: multiple point source (MPS) and spatial mesh based surface source (SMBSS). To validate this SM, MCNPX2.6 was used to generate two PSFs for a 6MV photon beam from a Varian 2100C/D linear accelerator. Results: PDDs and profiles were calculated using the SM and original PSF for different field sizes from 5×5 to 40×40cm2. Agreement was within 2% of the maximum dose at 100cm SSD and 2.5% of the maximum dose at 200cm SSD... 

    Accuracy of Kinect's skeleton tracking for upper body rehabilitation applications

    , Article Disability and Rehabilitation: Assistive Technology ; Vol. 9, issue. 4 , 2014 , pp. 344-352 ; ISSN: 17483107 Mobini, A ; Behzadipour, S ; Saadat Foumani, M ; Sharif University of Technology
    Abstract
    Games and their use in rehabilitation have formed a new and rapidly growing area of research. A critical hardware component of rehabilitation programs is the input device that measures the patients' movements. After Microsoft released Kinect, extensive research has been initiated on its applications as an input device for rehabilitation. However, since most of the works in this area rely on a qualitative determination of the joints' movements rather than an accurate quantitative one, detailed analysis of patients' movements is hindered. The aim of this article is to determine the accuracy of the Kinect's joint tracking. To fulfill this task, a model of upper body was fabricated. The... 

    Minimization of target registration error for vertebra in image-guided spine surgery

    , Article International Journal of Computer Assisted Radiology and Surgery ; Vol. 9, issue. 1 , January , 2014 , p. 29-38 Ershad, M ; Ahmadian, A ; Dadashi Serej, N ; Saberi, H ; Amini Khoiy, K ; Sharif University of Technology
    Abstract
    Purpose: The accuracy of pedicle screw placement during image-guided spine surgery (IGSS) can be characterized by estimating the target registration error (TRE). The major factors that influence TRE were identified, minimized, and verified with in vitro experiments. Materials and methods: Computed-tomography- compatible markers are placed over anatomical landmarks of lumbar vertebral segments in locations that are feasible and routinely used in surgical procedures. TRE was determined directly for markers placed on the pedicles of vertebra segments. First, optimum selections of landmarks are proposed for different landmarks according to the minimum achievable TRE values in different... 

    1H NMR based metabolic profiling in Crohn's disease by random forest methodology

    , Article Magnetic Resonance in Chemistry ; Vol. 52, issue. 7 , July , 2014 , p. 370-376 Fathi, F ; Majari-Kasmaee, L ; Mani-Varnosfaderani, A ; Kyani, A ; Rostami-Nejad, M ; Sohrabzadeh, K ; Naderi, N ; Zali, M. R ; Rezaei-Tavirani, M ; Tafazzoli, M ; Arefi-Oskouie, A ; Sharif University of Technology
    Abstract
    The present study was designed to search for metabolic biomarkers and their correlation with serum zinc in Crohn's disease patients. Crohn's disease (CD) is a form of inflammatory bowel disease that may affect any part of the gastrointestinal tract and can be difficult to diagnose using the clinical tests. Thus, introduction of a novel diagnostic method would be a major step towards CD treatment.Proton nuclear magnetic resonance spectroscopy ( 1H NMR) was employed for metabolic profiling to find out which metabolites in the serum have meaningful significance in the diagnosis of CD. CD and healthy subjects were correctly classified using random forest methodology. The classification model for... 

    Analysis of different material theories used in a FE model of a lumbar segment motion

    , Article Acta of Bioengineering and Biomechanics ; Volume 15, Issue 2 , 2013 , Pages 33-41 ; 1509409X (ISSN) Gohari, E ; Nikkhoo, M ; Haghpanahi, M ; Parnianpour, M ; Sharif University of Technology
    2013
    Abstract
    In this study, a nonlinear poroelastic model of intervertebral disc as an infrastructure was developed. Moreover, a new element was defined consisting a disc (Viscoelastic Euler Beam Element) and a vertebra (Rigid Link) as a unit element. Using the new element, three different viscoelastic finite element models were prepared for lumbar motion segment (L4/L5). Prolonged loading (short-term and long-term creep) and cyclic loading were applied to the models and the results were compared with results of in vivo tests. Simplification of the models by using the new element leads to reduction of the runtime of the models in dynamic analyses to few minutes without losing the accuracy in the results  

    Predicting hourly air pollutant levels using artificial neural networks coupled with uncertainty analysis by Monte Carlo simulations

    , Article Environmental Science and Pollution Research ; Volume 20, Issue 7 , 2013 , Pages 4777-4789 ; 09441344 (ISSN) Arhami, M ; Kamali, N ; Rajabi, M. M ; Sharif University of Technology
    2013
    Abstract
    Recent progress in developing artificial neural network (ANN) metamodels has paved the way for reliable use of these models in the prediction of air pollutant concentrations in urban atmosphere. However, improvement of prediction performance, proper selection of input parameters and model architecture, and quantification of model uncertainties remain key challenges to their practical use. This study has three main objectives: to select an ensemble of input parameters for ANN metamodels consisting of meteorological variables that are predictable by conventional weather forecast models and variables that properly describe the complex nature of pollutant source conditions in a major city, to... 

    Automatic segmentation of brain MRI in high-dimensional local and non-local feature space based on sparse representation

    , Article Magnetic Resonance Imaging ; Volume 31, Issue 5 , 2013 , Pages 733-741 ; 0730725X (ISSN) Khalilzadeh, M. M ; Fatemizadeh, E ; Behnam, H ; Sharif University of Technology
    2013
    Abstract
    Automatic extraction of the varying regions of magnetic resonance images is required as a prior step in a diagnostic intelligent system. The sparsest representation and high-dimensional feature are provided based on learned dictionary. The classification is done by employing the technique that computes the reconstruction error locally and non-locally of each pixel. The acquired results from the real and simulated images are superior to the best MRI segmentation method with regard to the stability advantages. In addition, it is segmented exactly through a formula taken from the distance and sparse factors. Also, it is done automatically taking sparse factor in unsupervised clustering methods... 

    In situ solid-phase microextraction and post on-fiber derivatization combined with gas chromatography-mass spectrometry for determination of phenol in occupational air

    , Article Analytica Chimica Acta ; Volume 742 , 2012 , Pages 17-21 ; 00032670 (ISSN) Es haghi, A ; Baghernejad, M ; Bagheri, H ; Sharif University of Technology
    Elsevier  2012
    Abstract
    A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography-mass spectrometry detection (GC-MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol-gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature,... 

    Fabrication of a modified electrode based on Fe3 O4 NPs/MWCNT nanocomposite: Application to simultaneous determination of guanine and adenine in DNA

    , Article Bioelectrochemistry ; Volume 86 , 2012 , Pages 78-86 ; 15675394 (ISSN) Shahrokhian, S ; Rastgar, S ; Amini, M. K ; Adeli, M ; Sharif University of Technology
    Abstract
    Multi-walled carbon nanotubes decorated with Fe 3O 4 nanoparticles (Fe 3O 4NPs/MWCNT) were prepared and used to construct a novel biosensor for the simultaneous detection of adenine and guanine. The direct electro-oxidation of adenine and guanine on the modified electrode were investigated by linear sweep voltammetry. The results indicate a remarkable increase in the oxidation peak currents together with negative shift in the oxidation peak potentials for both adenine and guanine, in comparison to the bare glassy carbon electrode (GCE). The surface morphology and nature of the composite film deposited on GCE were characterized by transmission electron microscopy, atomic force microscopy,... 

    Aniline-silica nanocomposite as a novel solid phase microextraction fiber coating

    , Article Journal of Chromatography A ; Volume 1238 , May , 2012 , Pages 22-29 ; 00219673 (ISSN) Bagheri, H ; Roostaie, A ; Sharif University of Technology
    2012
    Abstract
    A new unbreakable solid phase microextraction (SPME) fiber coating based on aniline-silica nanocomposite was electrodeposited on a stainless steel wire. The electropolymerization process was carried out at a constant deposition potential, applied to the corresponding aqueous electrolyte containing aniline and silica nanoparticles. The scanning electron microscopy (SEM) images showed the non-smooth and the porous surface structure of the prepared nanocomposite. The applicability of the new fiber coating was examined by headspace-solid phase microextraction (HS-SPME) of some environmentally important polycyclic aromatic hydrocarbons (PAHs), as model compounds, from aqueous samples.... 

    Amperometric sulfide detection using Coprinus cinereus peroxidase immobilized on screen printed electrode in an enzyme inhibition based biosensor

    , Article Biosensors and Bioelectronics ; Volume 35, Issue 1 , 2012 , Pages 297-301 ; 09565663 (ISSN) Savizi, I. S. P ; Kariminia, H. R ; Ghadiri, M ; Roosta Azad, R ; Sharif University of Technology
    2012
    Abstract
    In the present work, an amperometric inhibition biosensor for the determination of sulfide has been fabricated by immobilizing Coprinus cinereus peroxidase (CIP) on the surface of screen printed electrode (SPE). Chitosan/acrylamide was applied for immobilization of peroxidase on the working electrode. The amperometric measurement was performed at an applied potential of -150. mV versus Ag/AgCl with a scan rate of 100. mV in the presence of hydroquinone as electron mediator and 0.1. M phosphate buffer solution of pH 6.5. The variables influencing the performance of sensor including the amount of substrate, mediator concentration and electrolyte pH were optimized. The determination of sulfide... 

    Reinforced polydiphenylamine nanocomposite for microextraction in packed syringe of various pesticides

    , Article Journal of Chromatography A ; Volume 1222 , January , 2012 , Pages 13-21 ; 00219673 (ISSN) Bagheri, H ; Ayazi, Z ; Es'haghi, A ; Aghakhani, A ; Sharif University of Technology
    2012
    Abstract
    Reinforced polydiphenylamine (PDPA) nanocomposite was synthesized by oxidation of diphenylamine in 4molL-1 sulfuric acid solution containing a fixed amount of carbon nanotubes (CNTs) in the presence of cetyltrimethylammonium bromide (CTAB). The surface characteristic of PDPA and PDPA/CNT nanocomposites was investigated using scanning electron microscopy (SEM). The prepared PDPA/CNT nanocomposite was used as an extraction medium for microextraction in packed syringe (MEPS) of selected pesticides from aquatic environment. The effect of CNT doping level and the presence of surfactant on the extraction capability of nanocomposite was investigated and it was revealed that when 4% (w/w) of CNT in... 

    Mediator-less highly sensitive voltammetric detection of glutamate using glutamate dehydrogenase/vertically aligned CNTs grown on silicon substrate

    , Article Biosensors and Bioelectronics ; Volume 31, Issue 1 , 2012 , Pages 110-115 ; 09565663 (ISSN) Gholizadeh, A ; Shahrokhian, S ; Iraji zad, A ; Mohajerzadeh, S ; Vosoughi, M ; Darbari, S ; Sanaee, Z ; Sharif University of Technology
    Abstract
    A sensitive glutamate biosensor is prepared based on glutamate dehydrogenase/vertically aligned carbon nanotubes (GLDH, VACNTs). Vertically aligned carbon nanotubes were grown on a silicon substrate by direct current plasma enhanced chemical vapor deposition (DC-PECVD) method. The electrochemical behavior of the synthesized VACNTs was investigated by cyclic voltammetry and electrochemical impedance spectroscopic methods. Glutamate dehydrogenase covalently attached on tip of VACNTs. The electrochemical performance of the electrode for detection of glutamate was investigated by cyclic and differential pulse voltammetry. Differential pulse voltammetric determinations of glutamate are performed... 

    An unbreakable on-line approach towards sol-gel capillary microextraction

    , Article Journal of Chromatography A ; Volume 1218, Issue 26 , 2011 , Pages 3952-3957 ; 00219673 (ISSN) Bagheri, H ; Piri-Moghadam, H ; Es'haghi, A ; Sharif University of Technology
    2011
    Abstract
    In this work a novel unbreakable sol-gel-based in-tube device for on-line solid phase microextraction (SPME) was developed. The inner surface of a copper tube, intended to be used as a high performance liquid chromatography (HPLC) loop, was electrodeposited by metallic Cu followed by the self assembled monolayers (SAM) of 3-(mercaptopropyl) trimethoxysilane (3MPTMOS). Then, poly (ethyleneglycol) (PEG) was chemically bonded to the -OH sites of the SAM already covering the inner surface of the copper loop using sol-gel technology. The homogeneity and the porous surface structure of the SAM and sol-gel coatings were examined using the scanning electron microscopy (SEM) and adsorption/desorption... 

    Speed/accuracy trade-off between the habitual and the goal-directed processes

    , Article PLoS Computational Biology ; Volume 7, Issue 5 , 2011 ; 1553734X (ISSN) Keramati, M ; Dezfouli, A ; Piray, P ; Sharif University of Technology
    2011
    Abstract
    Instrumental responses are hypothesized to be of two kinds: habitual and goal-directed, mediated by the sensorimotor and the associative cortico-basal ganglia circuits, respectively. The existence of the two heterogeneous associative learning mechanisms can be hypothesized to arise from the comparative advantages that they have at different stages of learning. In this paper, we assume that the goal-directed system is behaviourally flexible, but slow in choice selection. The habitual system, in contrast, is fast in responding, but inflexible in adapting its behavioural strategy to new conditions. Based on these assumptions and using the computational theory of reinforcement learning, we... 

    Modification of glassy carbon electrode with a bilayer of multiwalled carbon nanotube/tiron-doped polypyrrole: Application to sensitive voltammetric determination of acyclovir

    , Article Materials Science and Engineering C ; Volume 53 , 2015 , Pages 134-141 ; 09284931 (ISSN) Shahrokhian, S ; Azimzadeh, M ; Amini, M. K ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    A novel voltammetric sensor based on glassy carbon electrode (GCE) modified with a thin film of multi-walled carbon nanotubes (MWCNTs) coated with an electropolymerized layer of tiron-doped polypyrrole was developed and the resulting electrode was applied for the determination of acyclovir (ACV). The surface morphology and property of the modified electrode were characterized by field emission scanning electron microscopy and electrochemical impedance spectroscopy techniques. The electrochemical performance of the modified electrode was investigated by means of linear sweep voltammetry (LSV). The effect of several experimental variables, such as pH of the supporting electrolyte, drop size of... 

    Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram

    , Article Journal of Healthcare Engineering ; Volume 6, Issue 1 , 2015 , Pages 121-144 ; 20402295 (ISSN) Zahedi, E ; Sohani, V ; Mohd. Ali, M. A ; Chellappan, K ; Beng, G. K ; Sharif University of Technology
    Multi-Science Publishing Co. Ltd  2015
    Abstract
    The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was... 

    Optimisation of a microwave-assisted method for extracting withaferin A from Withania somnifera Dunal. using central composite design

    , Article Phytochemical Analysis ; Volume 21, Issue 6 , 2010 , Pages 544-549 ; 09580344 (ISSN) Mirzajani, F ; Ghassempour, A ; Jalali-Heravi, M ; Mirjalili, M. H ; Sharif University of Technology
    2010
    Abstract
    Introduction - Recently, there have been growing attention on the modification and optimisation of new extraction and quantification methods, caused by the lack of environmentally friendly methodologies for the extraction of phytochemicals from complex matrices. In the case of pharmaceutical compounds, not only the extraction procedure but also the analysis method should be efficient, precise, fast and easy.Objectives - The essential pharmaceutical characteristics and trace concentration of withanolides led us to modify and optimise the previously reported extraction and quantification procedure for withaferin A (WA) as a candidate for withanolides.Matrial and methods - The WA from the... 

    Reliability of recurrence quantification analysis measures of the center of pressure during standing in individuals with musculoskeletal disorders

    , Article Medical Engineering and Physics ; Volume 32, Issue 7 , 2010 , Pages 808-812 ; 13504533 (ISSN) Mazaheri, M ; Negahban, H ; Salavati, M ; Sanjari, M. A ; Parnianpour, M ; Sharif University of Technology
    2010
    Abstract
    Although the application of nonlinear tools including recurrence quantification analysis (RQA) has increasingly grown in the recent years especially in balance-disordered populations, there have been few studies which determine their measurement properties. Therefore, a methodological study was performed to estimate the intersession and intrasession reliability of some dynamic features provided by RQA for nonlinear analysis of center of pressure (COP) signals recorded during quiet standing in a sample of patients with musculoskeletal disorders (MSDs) including low back pain (LBP), anterior cruciate ligament (ACL) injury and functional ankle instability (FAI). The subjects completed postural...