Loading...
Search for: range-of-motion
0.008 seconds
Total 35 records

    Dynamic comparison of segmentary scapulohumeral rhythm between athletes with and without impingement syndrome

    , Article Iranian Journal of Radiology ; Vol. 11, issue. 2 , 2014 Taghizadeh Delkhoush, C ; Maroufi, N ; Ebrahimi Takamjani, I ; Farahmand, F ; Shakourirad, A ; Haghani, H ; Sharif University of Technology
    Abstract
    Background: Patients who have shoulder pain usually have compensatory or contributory deviation of shoulder motion during arm elevation. In the traditional scapulohumeral rhythm, the share of the acromioclavicular (AC) and the sternoclavicular (SC) joint movements and also the role of AC internal rotation angle are unknown. Objectives: The main purpose of this study was to measure and compare the segmentary scapulohumeral rhythm (SSHR) during scapular arm elevation at a steady rotational speed in athletes with and without impingement syndrome. Patients and Methods: Using a speedometer, the maximum speed of arm elevation was measured in 21 men in each of the involved and uninvolved groups.... 

    Lumbopelvic rhythm during forward and backward sagittal trunk rotations: Combined in vivo measurement with inertial tracking device and biomechanical modeling

    , Article Clinical Biomechanics ; Vol. 29, issue. 1 , 2014 , pp. 7-13 ; ISSN: 02680033 Tafazzol, A ; Arjmand, N ; Shirazi-Adl, A ; Parnianpour, M ; Sharif University of Technology
    Abstract
    Background The ratio of total lumbar rotation over pelvic rotation (lumbopelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Methods Angular rotations of the pelvis and lumbar spine as well as their sagittal rhythm during forward flexion and backward extension in upright standing of eight asymptomatic males are measured using an inertial tracking device. The effect of variations in the lumbopelvic ratio during trunk flexion on spinal loads is quantified using a detailed musculoskeletal model. Findings The mean of peak voluntary flexion rotations of the thorax, pelvis, and lumbar was 121 (SD... 

    Uncontrolled manifold analysis of gait kinematic synergy during normal and narrow path walking in individuals with knee osteoarthritis compared to asymptomatic individuals

    , Article Journal of Biomechanics ; Volume 141 , 2022 ; 00219290 (ISSN) Shafizadegan, Z ; Sarrafzadeh, J ; Farahmand, F ; Salehi, R ; Rasouli, O ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Knee osteoarthritis (KOA) is a common musculoskeletal disorder resulting in altered gait patterns. Uncontrolled manifold (UCM) analysis has been demonstrated as a useful approach for quantitative analysis of motor variability and synergies. The present study aimed to investigate the changes in the kinematic synergy, controlling the center of mass (COM) position while walking on normal and narrow paths in people with KOA compared to asymptomatic participants. In this cross-sectional study, twenty people with mild to moderate KOA and twenty asymptomatic individuals walked at their comfortable preferred speed across normal and narrow paths on a treadmill. The UCM analysis was performed... 

    Trajectory of human movement during sit to stand: A new modeling approach based on movement decomposition and multi-phase cost function

    , Article Experimental Brain Research ; Volume 229, Issue 2 , 2013 , Pages 221-234 ; 00144819 (ISSN) Sadeghi, M ; Andani, M. E ; Bahrami, F ; Parnianpour, M ; Sharif University of Technology
    2013
    Abstract
    The purpose of this work is to develop a computational model to describe the task of sit to stand (STS). STS is an important movement skill which is frequently performed in human daily activities, but has rarely been studied from the perspective of optimization principles. In this study, we compared the recorded trajectories of STS with the trajectories generated by several conventional optimization-based models (i.e., minimum torque, minimum torque change and kinetic energy cost models) and also with the trajectories produced by a novel multi-phase cost model (MPCM). In the MPCM, we suggested that any complex task, such as STS, is decomposable into successive motion phases, so that each... 

    A novel coupled musculoskeletal finite element model of the spine – Critical evaluation of trunk models in some tasks

    , Article Journal of Biomechanics ; Volume 119 , 2021 ; 00219290 (ISSN) Rajaee, M. A ; Arjmand, N ; Shirazi Adl, A ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    Spine musculoskeletal (MS) models make simplifying assumptions on the intervertebral joint degrees-of-freedom (rotational and/or translational), representation (spherical or beam-like joints), and properties (linear or nonlinear). They also generally neglect the realistic structure of the joints with disc nuclei/annuli, facets, and ligaments. We aim to develop a novel MS model where trunk muscles are incorporated into a detailed finite element (FE) model of the ligamentous T12-S1 spine thus constructing a gold standard coupled MS-FE model. Model predictions are compared under some tasks with those of our earlier spherical joints, beam joints, and hybrid (uncoupled) MS-FE models. The coupled... 

    The gait and energy efficiency of stance control knee-ankle-foot orthoses: A literature review

    , Article Prosthetics and Orthotics International ; Volume 40, Issue 2 , 2016 , Pages 202-214 ; 03093646 (ISSN) Rafiaei, M ; Bahramizadeh, M ; Arazpour, M ; Samadian, M ; Hutchins, S. W ; Farahmand, F ; Mardani, M. A ; Sharif University of Technology
    SAGE Publications Inc  2016
    Abstract
    Background: The use of knee-ankle-foot orthoses with drop locked knee joints produces some limitations for walking in subjects with quadriceps muscle weakness. The development of stance control orthoses can potentially improve their functionality. Objectives: The aim of this review was to compare the evidence of the effect of stance control orthoses to knee-ankle-foot orthoses with drop locked knee joints in improving kinematic variables and energy efficiency of walking by subjects with quadriceps muscle weakness caused by different pathologies. Study design: Literature review. Methods: Based on selected keywords and their composition, a search was performed in Google Scholar, PubMed,... 

    Rehabilitation after ACL injury: A fluoroscopic study on the effects of type of exercise on the knee sagittal plane arthrokinematics

    , Article BioMed Research International ; Volume 2013 , July , 2013 ; 23146133 (ISSN) Norouzi, S ; Esfandiarpour, F ; Shakourirad, A ; Salehi, R ; Akbar, M ; Farahmand, F ; Sharif University of Technology
    2013
    Abstract
    A safe rehabilitation exercise for anterior cruciate ligament (ACL) injuries needs to be compatible with the normal knee arthrokinematics to avoid abnormal loading on the joint structures. The objective of this study was to measure the amount of the anterior tibial translation (ATT) of the ACL-deficient knees during selective open and closed kinetic chain exercises. The intact and injured knees of fourteen male subjects with unilateral ACL injury were imaged using uniplanar fluoroscopy, while the subjects performed forward lunge and unloaded/loaded open kinetic knee extension exercises. The ATTs were measured from fluoroscopic images, as the distance between the tibial and femoral reference... 

    The biomechanical response of the lower cervical spine post laminectomy: geometrically-parametric patient-specific finite element analyses

    , Article Journal of Medical and Biological Engineering ; Volume 41, Issue 1 , 2021 , Pages 59-70 ; 16090985 (ISSN) Nikkhoo, M ; Cheng, C. H ; Wang, J. L ; Niu, C. C ; Parnianpour, M ; Khalaf, K ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2021
    Abstract
    Purpose: This study aimed to investigate the biomechanical impact of laminectomy on cervical intersegmental motion and load sharing using a parametric patient-specific finite element (FE) model towards providing clinicians with a viable quantitative tool for informed decision-making and improved surgical planning. Methods: Ten subject-specific nonlinear osteo-ligamentous cervical spine (C3–C7) FE models were developed using X-ray image-based algorithms. The models were used to evaluate the effect of laminectomy on lower cervical spine biomechanics for two-level (C3–C4) and three-level (C3–C5) laminectomy procedures. Results: The average cervical spine ranges of motion (ROM) for the pre-op... 

    Effects of eight different ligament property datasets on biomechanics of a lumbar L4-L5 finite element model

    , Article Journal of Biomechanics ; 2017 ; 00219290 (ISSN) Naserkhaki, S ; Arjmand, N ; Shirazi Adl, A ; Farahmand, F ; El Rich, M ; Sharif University of Technology
    Abstract
    Ligaments assist trunk muscles in balancing external moments and providing spinal stability. In absence of the personalized material properties for ligaments, finite element (FE) models use dispersed data from the literature. This study aims to investigate the relative effects of eight different ligament property datasets on FE model responses. Eight L4-L5 models distinct only in ligament properties were constructed and loaded under moment (15. N. m) alone or combined with a compressive follower load (FL). Range of motions (RoM) of the disc-alone model matched well in vitro data. Ligament properties significantly affected only sagittal RoMs (∼3.0-7.1° in flexion and ∼3.8-5.8° in extension at... 

    Effects of eight different ligament property datasets on biomechanics of a lumbar L4-L5 finite element model

    , Article Journal of Biomechanics ; Volume 70 , 2018 , Pages 33-42 ; 00219290 (ISSN) Naserkhaki, S ; Arjmand, N ; Shirazi Adl, A ; Farahmand, F ; El Rich, M ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Ligaments assist trunk muscles in balancing external moments and providing spinal stability. In absence of the personalized material properties for ligaments, finite element (FE) models use dispersed data from the literature. This study aims to investigate the relative effects of eight different ligament property datasets on FE model responses. Eight L4-L5 models distinct only in ligament properties were constructed and loaded under moment (15 N m) alone or combined with a compressive follower load (FL). Range of motions (RoM) of the disc-alone model matched well in vitro data. Ligament properties significantly affected only sagittal RoMs (∼3.0–7.1° in flexion and ∼3.8–5.8° in extension at... 

    Three-dimensional primary and coupled range of motions and movement coordination of the pelvis, lumbar and thoracic spine in standing posture using inertial tracking device

    , Article Journal of Biomechanics ; Volume 69 , March , 2018 , Pages 169-174 ; 00219290 (ISSN) Narimani, M ; Arjmand, N ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Evaluation of spinal range of motions (RoMs) and movement coordination between its segments (thorax, lumbar, and pelvis) has clinical and biomechanical implications. Previous studies have not recorded three-dimensional primary/coupled motions of all spinal segments simultaneously. Moreover, magnitude/direction of the coupled motions of the thorax/pelvis in standing posture and lumbopelvic rhythms in the frontal/transverse planes have not been investigated. This study, hence, used an inertial tracking device to measure T1, T5, T12, total (T1-T12) thoracic, lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), and pelvis primary and coupled RoMs as well as their movement coordination in... 

    Accuracy of Kinect's skeleton tracking for upper body rehabilitation applications

    , Article Disability and Rehabilitation: Assistive Technology ; Vol. 9, issue. 4 , 2014 , pp. 344-352 ; ISSN: 17483107 Mobini, A ; Behzadipour, S ; Saadat Foumani, M ; Sharif University of Technology
    Abstract
    Games and their use in rehabilitation have formed a new and rapidly growing area of research. A critical hardware component of rehabilitation programs is the input device that measures the patients' movements. After Microsoft released Kinect, extensive research has been initiated on its applications as an input device for rehabilitation. However, since most of the works in this area rely on a qualitative determination of the joints' movements rather than an accurate quantitative one, detailed analysis of patients' movements is hindered. The aim of this article is to determine the accuracy of the Kinect's joint tracking. To fulfill this task, a model of upper body was fabricated. The... 

    Stiffness of knee-spanning external fixation systems for traumatic knee dislocations: A biomechanical study

    , Article Journal of Orthopaedic Trauma ; Volume 24, Issue 11 , Nov , 2010 , Pages 693-696 ; 08905339 (ISSN) Mercer, D ; Firoozbakhsh, K ; Prevost, M ; Mulkey, P ; Decoster, T. A ; Schenck, R ; Sharif University of Technology
    2010
    Abstract
    Objective: The purpose of this study was to compare the relative stiffness of four common external fixation (XF) configurations used to span and stabilize the knee after knee dislocation. Methods: Synthetic composite femora and tibiae connected with cords were used to simulate a knee. Four configurations of external fixation were tested: anterior femoral pins with monotube (XF1), anterolateral femoral pins with monotube (XF2), anterolateral femoral pins with two connecting rods (XF3), and hinged ring fixator (XF4). Six specimens of each configuration were loaded nondestructively in varus/valgus, anterior-to- posterior shear, flexion/extension, axial compression, internal/external torsion,... 

    Biomechanical analysis of the pelvis angular excursion in sagittal plane in response to asymmetric leg loading tasks in females with and without nonspecific chronic low back pain

    , Article Journal of Biomedical Physics and Engineering ; Volume 11, Issue 3 , 2021 , Pages 367-376 ; 22517200 (ISSN) Meftahi, N ; Kamali, F ; Parni Anpour, M ; Davoudi, M ; Sharif University of Technology
    Shriaz University of Medical Sciences  2021
    Abstract
    Background: Controlling pelvic excursions is the focus of stabilization exercises such as legs loading tasks in rehabilitation of non-specific chronic low back pain (NSCLBP) patients. Progression of these exercises is based on the ability to perform tasks with minimal sagittal pelvic excursions. In spite of emphasis on minimizing pelvic motions, no previous studies have investigated kinematic analysis of the pelvic excursions during leg loading exercises in NSCLBP patients. Objective: This study aims to investigate the sagittal pelvis excursion during performing asymmetric leg loading tasks in individuals with and without NSCLBP. Material and Methods: In this cross-sectional study, kinematic... 

    Sagittal range of motion of the thoracic spine using standing digital radiography: A throughout comparison with non-radiographic data reviewed from the literature

    , Article Scientia Iranica ; Volume 26, Issue 3B , 2019 , Pages 1307-1315 ; 10263098 (ISSN) Madinei, S. S ; Arjmand, N ; Sharif University of Technology
    Sharif University of Technology  2019
    Abstract
    Previous studies have measured thoracic Range of Motion (RoM) using either skin-mounted devices or supine CT-imaging and have reported on quite different RoMs. Given the inherent shortcomings of measurements of vertebrae movements from the overlying skin, the present study aims to measure normal RoM of the thoracic spine in the sagittal plane using the upright digital radiography. Lateral radiographs of the thoracic spine were obtained from eight asymptomatic male subjects in upright standing and full forward flexion using a mobile U-arm digital radiographic system. Total (T1-T12), upper (T1-T6), and lower (T6-T12) thoracic RoMs were measured. A throughout comparison of available skin-based... 

    Sagittal range of motion of the thoracic spine using standing digital radiography: A throughout comparison with non-radiographic data reviewed from the literature

    , Article Scientia Iranica ; Volume 26, Issue 3B , 2019 , Pages 1307-1315 ; 10263098 (ISSN) Madinei, S ; Arjmand, N ; Sharif University of Technology
    Sharif University of Technology  2019
    Abstract
    Previous studies have measured thoracic Range of Motion (RoM) using either skin-mounted devices or supine CT-imaging and have reported on quite different RoMs. Given the inherent shortcomings of measurements of vertebrae movements from the overlying skin, the present study aims to measure normal RoM of the thoracic spine in the sagittal plane using the upright digital radiography. Lateral radiographs of the thoracic spine were obtained from eight asymptomatic male subjects in upright standing and full forward flexion using a mobile U-arm digital radiographic system. Total (T1-T12), upper (T1-T6), and lower (T6-T12) thoracic RoMs were measured. A throughout comparison of available skin-based... 

    The effect of functional bracing on the arthrokinematics of anterior cruciate ligament injured knees during lunge exercise

    , Article Gait and Posture ; Volume 63 , 2018 , Pages 52-57 ; 09666362 (ISSN) Jalali, M ; Farahmand, F ; Esfandiarpour, F ; Golestanha, S. A ; Akbar, M ; Eskandari, A ; Mousavi, S. E ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Background: Functional knee braces are extensively used for partially and completely torn anterior cruciate ligament (ACL) patients and those who have undergone ACL graft reconstruction, in order to support the healing ACL, improve the joint's functional stability, and restore the normal joint kinematics. Research question: Does wearing braces alter the arthrokinematics of the ACL deficient knees during lung exercise? Methods: For ten male unilateral ACL deficient subjects, 3D knee models were reconstructed from CT images, acquired in rest position. Sagittal plane fluoroscopy was then performed throughout a complete cycle of lunge in braced and non-braced conditions. The 3D kinematics of the... 

    The effects of trochlear groove geometry on patellofemoral joint stability - A computer model study

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 222, Issue 1 , 2008 , Pages 75-88 ; 09544119 (ISSN) Jafari, A ; Farahmand, F ; Meghdari, A ; Sharif University of Technology
    2008
    Abstract
    The effect of the variation in the femoral groove geometry on patellofemoral joint stability was studied using a two dimensional transverse plane model with deformable articular surfaces. The femoral and patellar bony structures were modelled as rigid bodies with their profiles expressed by splines. The articular cartilage was discretized into compression springs, distributed along the femoral and patellar profiles, based on the rigid-body spring model. The medial and lateral retinacula were modelled as linear tensile springs, and the quadriceps muscles and patellar tendon as strings with known tension. The anatomical data were obtained from the transverse plane magnetic resonance images of... 

    Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions

    , Article Journal of Biomechanics ; Volume 49, Issue 6 , 2016 , Pages 913-918 ; 00219290 (ISSN) Hajibozorgi, M ; Arjmand, N ; Sharif University of Technology
    Elsevier Ltd 
    Abstract
    Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvis, and entire trunk (T1) ROMs were measured using an inertial tracking device as asymptomatic subjects flexed forward from their neutral upright position to full forward flexion. Correlations between body height and the ROMs were conducted. An effect of measurement errors of the trunk flexion (T1) on the model-predicted spinal loads was investigated. Mean of peak voluntary total... 

    Trunk, pelvis, and knee kinematics during running in females with and without patellofemoral pain

    , Article Gait and Posture ; Volume 89 , 2021 , Pages 80-85 ; 09666362 (ISSN) Haghighat, F ; Ebrahimi, S ; Rezaie, M ; Shafiee, E ; Shokouhyan, S. M ; Motealleh, A ; Parnianpour, M ; Sharif University of Technology
    Elsevier B.V  2021
    Abstract
    Background: Females are two times more likely to develop patellofemoral pain (PFP) than males. Abnormal trunk and pelvis kinematics are thought to contribute to the pathomechanics of this condition. However, there is a scarcity of evidence investigating proximal segments kinematics in females with PFP. Research question: The purpose of this study was to investigate whether females with PFP demonstrate altered trunk, pelvis, and knee joint kinematics compared with healthy controls during running. Methods: Thirty-four females (17 PFP, 17 controls) underwent a 3-dimensional motion analysis during treadmill running at preferred and fixed speeds, each trial for 30 s. Variables of interest...