Loading...
Search for: high-throughput
0.006 seconds
Total 46 records

    Numerical Investigation of Droplet Generation in a Microfluidic Flow-Focusing Junction Aiming High-Throughput Droplet Generation

    , M.Sc. Thesis Sharif University of Technology Mardani Boldaji, Fatemeh (Author) ; Taghipoor, Mojtaba (Supervisor) ; Hosseini, Vahid (Supervisor)
    Abstract
    Droplet microfluidic platform generates monodisperse droplets in a desired size through immiscible multiphase flows inside microchannels. Droplets are individual reactor and can be used for bio(chemical) analyses. Also, for materials fabrication, droplet microfluidics offers a versatile platform for generation of nano- or micro-sized particles and microcapsules that are widely used in drug delivery. In addition to the monodispersity, high-throughput generation is also necessary in many applications. Therefore, droplets must be formed in stable regimes (dripping and squeezing) in the highest possible frequency. In this study, the flow-focusing geometry, which is the most common geometry in... 

    Quantification of in Vitro Drug Effects on COVID-19 through Analysis of Cellular Morphological Features

    , M.Sc. Thesis Sharif University of Technology Mirzaie, Nahal (Author) ; Rohban, Mohammad Hossein (Supervisor) ; Sharifi Zarchi, Ali (Supervisor)
    Abstract
    The epidemic of Covid 19 has killed millions of people worldwide. Despite the efforts of scientists around the world, there is still no cure for this disease. Approval of newly designed drugs due to clinical trial periods is time-consuming and costly. For this reason, in the current emergency situation, it is important to have a solution for screening available approved drugs in order to find effective substances for this disease.High-throughput assays are a good option for such problems. In this field of research, image-based high-throughput assays are amongst the most effective and cost-effective methods that help quantify the response of treated cells by measuring cell... 

    High-Throughput Determination of Pesticide Residues by Solid-Phase Microextraction and Micro-Solid Phase Extraction on 96-Well Plate

    , Ph.D. Dissertation Sharif University of Technology Eshaghi, Ali (Author) ; Bagheri, Habib (Supervisor) ; Es-haghi, Ali ($item.subfieldsMap.e)
    Abstract
    Novel high-throughput device and their applications as the microextraction systems for pesticide multiresidue determination is the centre of this research. 96 extracting unit based on solid phase microextraction and micro-Solid phase extraction were constructed and applied for high-throughput extraction.
    In the first work, a high-throughput SPME on 96-well plate together with gas chromatography-mass spectrometry was developed for the determination of pesticide residues in cucumber samples. A home-made Teflon block consisting ninety-six holes was constructed to 96 SPME fibers being positioned in. SPME fibers consisted of stainless steel rods with a 1.0 cm polydimethylsiloxane tubing... 

    Improvement of size-based particle separation throughput in slanted spiral microchannel by modifying outlet geometry

    , Article Electrophoresis ; Volume 41, Issue 5-6 , February , 2020 , Pages 353-359 Mihandoust, A ; Maleki Jirsaraei, N ; Rouhani, S ; Safi, S ; Alizadeh, M ; Sharif University of Technology
    Wiley-VCH Verlag  2020
    Abstract
    The inertial microfluidic technique, as a powerful new tool for accurate cell/particle separation based on the hydrodynamic phenomenon, has drawn considerable interest in recent years. Despite numerous microfluidic techniques of particle separation, there are few articles in the literature on separation techniques addressing external outlet geometry to increase the throughput efficiency and purity. In this work, we report on a spiral inertial microfluidic device with high efficiency (>98%). Herein, we demonstrate how changing the outlet geometry can improve the particle separation throughput. We present a complete separation of 4 and 6 μm from 10 μm particles potentially applicable to... 

    Microwave-assisted extraction and high-throughput monolithic-polymer-based micro-solid-phase extraction of organophosphorus, triazole, and organochlorine residues in apple

    , Article Journal of Separation Science ; Volume 39, Issue 3 , 2016 , Pages 576-583 ; 16159306 (ISSN) Bagheri, H ; Es Haghi, A ; Basiri Pour, F ; Sharif University of Technology
    Wiley-VCH Verlag 
    Abstract
    A high-throughput micro-solid-phase extraction device based on a 96-well plate was constructed and applied to the determination of pesticide residues in various apple samples. Butyl methacrylate and ethylene glycol dimethacrylate were copolymerized as a monolithic polymer and placed in the cylindrically shaped stainless-steel meshes of 96-micro-solid-phase extraction device and used as an extracting unit. Before the micro-solid-phase extraction, microwave-assisted extraction was employed to facilitate the transfer of the pesticide residues from the apple matrix to liquid media. Then, 1 mL of the aquatic samples was transferred into the 96-well plate and the 96-micro-solid-phase extraction... 

    High throughput blood plasma separation using a passive PMMA microfluidic device

    , Article Microsystem Technologies ; 2015 ; 09467076 (ISSN) Shamsi, A ; Shamloo, A ; Mohammadaliha, N ; Hajghassem, H ; Mehrabadi, J. F ; Bazzaz, M ; Sharif University of Technology
    Springer Verlag  2015
    Abstract
    Since plasma is rich in many biomarkers used in clinical diagnostic experiments, microscale blood plasma separation is a primitive step in most of microfluidic analytical chips. In this paper, a passive microfluidic device for on-chip blood plasma separation based on Zweifach–Fung effect and plasma skimming was designed and fabricated by hot embossing of microchannels on a PMMA substrate and thermal bonding process. Human blood was diluted in various times and injected into the device. The main novelty of the proposed microfluidic device is the design of diffuser-shaped daughter channels. Our results demonstrated that this design exerted a considerable positive influence on the separation... 

    High throughput blood plasma separation using a passive PMMA microfluidic device

    , Article Microsystem Technologies ; Volume 22, Issue 10 , 2016 , Pages 2447-2454 ; 09467076 (ISSN) Shamsi, A ; Shamloo, A ; Mohammadaliha, N ; Hajghassem, H ; Fallah Mehrabadi, J ; Bazzaz, M ; Sharif University of Technology
    Springer Verlag  2016
    Abstract
    Since plasma is rich in many biomarkers used in clinical diagnostic experiments, microscale blood plasma separation is a primitive step in most of microfluidic analytical chips. In this paper, a passive microfluidic device for on-chip blood plasma separation based on Zweifach–Fung effect and plasma skimming was designed and fabricated by hot embossing of microchannels on a PMMA substrate and thermal bonding process. Human blood was diluted in various times and injected into the device. The main novelty of the proposed microfluidic device is the design of diffuser-shaped daughter channels. Our results demonstrated that this design exerted a considerable positive influence on the separation... 

    Development of a colorimetric sensor array based on monometallic and bimetallic nanoparticles for discrimination of triazole fungicides

    , Article Analytical and Bioanalytical Chemistry ; April , 2021 ; 16182642 (ISSN) Kalantari, K ; Fahimi Kashani, N ; Hormozi Nezhad, M. R ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2021
    Abstract
    Due to the widespread use of pesticides and their harmful effects on humans and wildlife, monitoring their residual amounts in crops is critically essential but still challenging regarding the development of high-throughput approaches. Herein, a colorimetric sensor array has been proposed for discrimination and identification of triazole fungicides using monometallic and bimetallic silver and gold nanoparticles. Aggregation-induced behavior of AgNPs, AuNPs, and Au-AgNPs in the presence of four triazole fungicides produced a fingerprint response pattern for each analyte. Innovative changes to the metal composition of nanoparticles leads to the production of entirely distinct response patterns... 

    Development of a colorimetric sensor array based on monometallic and bimetallic nanoparticles for discrimination of triazole fungicides

    , Article Analytical and Bioanalytical Chemistry ; Volume 414, Issue 18 , 2022 , Pages 5297-5308 ; 16182642 (ISSN) Kalantari, K ; Fahimi Kashani, N ; Hormozi Nezhada, M. R ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2022
    Abstract
    Due to the widespread use of pesticides and their harmful effects on humans and wildlife, monitoring their residual amounts in crops is critically essential but still challenging regarding the development of high-throughput approaches. Herein, a colorimetric sensor array has been proposed for discrimination and identification of triazole fungicides using monometallic and bimetallic silver and gold nanoparticles. Aggregation-induced behavior of AgNPs, AuNPs, and Au-AgNPs in the presence of four triazole fungicides produced a fingerprint response pattern for each analyte. Innovative changes to the metal composition of nanoparticles leads to the production of entirely distinct response patterns... 

    Label-free detection of β-amyloid peptides (Aβ40 and Aβ42): a colorimetric sensor array for plasma monitoring of alzheimer's disease

    , Article Nanoscale ; Volume 10, Issue 14 , 2018 , Pages 6361-6368 ; 20403364 (ISSN) Ghasemi, F ; Hormozi Nezhad, M. R ; Mahmoudi, M ; Sharif University of Technology
    Royal Society of Chemistry  2018
    Abstract
    Monitoring the ratio of 40- and 42-residue amyloid β peptides (i.e., Aβ40 and Aβ42) in human plasma is considered one of the hallmarks of detection of the early stage of Alzheimer's disease (AD). Therefore, development of a specific, yet non-antibody-based method for simultaneous detection of Aβ40 and Aβ42 may have considerable clinical applications. Here, we developed a 'nanoparticle-based colorimetric sensor array' utilizing label-free gold and silver nanoparticles for visual detection of Aβ42 and Aβ40. Different aggregation behaviors of nanoparticles through their conjugation with Aβ42 and Aβ40 followed by the coordination of Aβ42 and Aβ40 with Cu(ii) led to diverse spectral and color... 

    HELIOS: High-speed sequence alignment in optics

    , Article PLoS Computational Biology ; Volume 18, Issue 11 , 2022 ; 1553734X (ISSN) Maleki, E ; Akbari Rokn Abadi, S ; Koohi, S ; Sharif University of Technology
    Public Library of Science  2022
    Abstract
    In response to the imperfections of current sequence alignment methods, originated from the inherent serialism within their corresponding electrical systems, a few optical approaches for biological data comparison have been proposed recently. However, due to their low performance, raised from their inefficient coding scheme, this paper presents a novel all-optical high-throughput method for aligning DNA, RNA, and protein sequences, named HELIOS. The HELIOS method employs highly sophisticated operations to locate character matches, single or multiple mutations, and single or multiple indels within various biological sequences. On the other hand, the HELIOS optical architecture exploits... 

    Whole genome sequencing of SARS-CoV2 strains circulating in Iran during five waves of pandemic

    , Article PLoS ONE ; Volume 17, Issue 5 May , 2022 ; 19326203 (ISSN) Yavarian, J ; Nejati, A ; Salimi, V ; Jandaghi, N.Z.S ; Sadeghi, K ; Abedi, A ; Zarchi, A. S ; Gouya, M. M ; Mokhtari Azad, T ; Sharif University of Technology
    Public Library of Science  2022
    Abstract
    Purpose Whole genome sequencing of SARS-CoV2 is important to find useful information about the viral lineages, variants of interests and variants of concern. As there are not enough data about the circulating SARS-CoV2 variants in Iran, we sequenced 54 SARS-CoV2 genomes during the 5 waves of pandemic in Iran. Methods After viral RNA extraction from clinical samples collected during the COVID-19 pandemic, next generation sequencing was performed using the Nextseq platform. The sequencing data were analyzed and compared with reference sequences. Results During the 1st wave, V and L clades were detected. The second wave was recognized by G, GH and GR clades. Circulating clades during the 3rd... 

    Image-based cell profiling enhancement via data cleaning methods

    , Article PLoS ONE ; Volume 17, Issue 5 May , 2022 ; 19326203 (ISSN) Rezvani, A ; Bigverdi, M ; Rohban, M. H ; Sharif University of Technology
    Public Library of Science  2022
    Abstract
    With the advent of high-throughput assays, a large number of biological experiments can be carried out. Image-based assays are among the most accessible and inexpensive technologies for this purpose. Indeed, these assays have proved to be effective in characterizing unknown functions of genes and small molecules. Image analysis pipelines have a pivotal role in translating raw images that are captured in such assays into useful and compact representation, also known as measurements. CellProfiler is a popular and commonly used tool for this purpose through providing readily available modules for the cell/nuclei segmentation, and making various measurements, or features, for each cell/nuclei.... 

    Mining the potential of label-free biosensors for in vitro antipsychotic drug screening

    , Article Biosensors ; Volume 8, Issue 1 , 2018 ; 20796374 (ISSN) Kilic, T ; Soler, M ; Fahimi Kashani, N ; Altug, H ; Carrara, S ; Sharif University of Technology
    MDPI AG  2018
    Abstract
    The pharmaceutical industry is facing enormous challenges due to high drug attribution rates. For the past decades, novel methods have been developed for safety and efficacy testing, as well as for improving early development stages. In vitro screening methods for drug-receptor binding are considered to be good alternatives for decreasing costs in the identification of drug candidates. However, these methods require lengthy and troublesome labeling steps. Biosensors hold great promise due to the fact that label-free detection schemes can be designed in an easy and low-cost manner. In this paper, for the first time in the literature, we aimed to compare the potential of label-free optical and... 

    High-throughput, label-free isolation of white blood cells from whole blood using parallel spiral microchannels with u-shaped cross-section

    , Article Biosensors ; Volume 11, Issue 11 , 2021 ; 20796374 (ISSN) Mehran, A ; Rostami, P ; Saidi, M. S ; Firoozabadi, B ; Kashaninejad, N ; Sharif University of Technology
    MDPI  2021
    Abstract
    Rapid isolation of white blood cells (WBCs) from whole blood is an essential part of any WBC examination platform. However, most conventional cell separation techniques are labor-intensive and low throughput, require large volumes of samples, need extensive cell manipulation, and have low purity. To address these challenges, we report the design and fabrication of a passive, label-free microfluidic device with a unique U-shaped cross-section to separate WBCs from whole blood using hydrodynamic forces that exist in a microchannel with curvilinear geometry. It is shown that the spiral microchannel with a U-shaped cross-section concentrates larger blood cells (e.g., WBCs) in the inner... 

    Dna-Rna hybrid (R-loop): From a unified picture of the mammalian telomere to the genome-wide profile

    , Article Cells ; Volume 10, Issue 6 , 2021 ; 20734409 (ISSN) Rassoulzadegan, M ; Sharifi Zarchi, A ; Kianmehr, L ; Sharif University of Technology
    MDPI  2021
    Abstract
    Local three-stranded DNA/RNA hybrid regions of genomes (R-loops) have been detected either by binding of a monoclonal antibody (DRIP assay) or by enzymatic recognition by RNaseH. Such a structure has been postulated for mouse and human telomeres, clearly suggested by the identification of the complementary RNA Telomeric repeat-containing RNA “TERRA”. However, the tremendous disparity in the information obtained with antibody-based technology drove us to investigate a new strategy. Based on the observation that DNA/RNA hybrids in a triplex complex genome co-purify with the double-stranded chromosomal DNA fraction, we developed a direct preparative approach from total protein-free cellular... 

    Graph traversal edit distance and extensions

    , Article Journal of Computational Biology ; Volume 27, Issue 3 , 2020 , Pages 317-329 Ebrahimpour Boroojeny, A ; Shrestha, A ; Sharifi Zarchi, A ; Gallagher, S. R ; Sahinalp, S. C ; Chitsaz, H ; Sharif University of Technology
    Mary Ann Liebert Inc  2020
    Abstract
    Many problems in applied machine learning deal with graphs (also called networks), including social networks, security, web data mining, protein function prediction, and genome informatics. The kernel paradigm beautifully decouples the learning algorithm from the underlying geometric space, which renders graph kernels important for the aforementioned applications. In this article, we give a new graph kernel, which we call graph traversal edit distance (GTED). We introduce the GTED problem and give the first polynomial time algorithm for it. Informally, the GTED is the minimum edit distance between two strings formed by the edge labels of respective Eulerian traversals of the two graphs.... 

    Combined effects of electric stimulation and microgrooves in cardiac tissue-on-a-chip for drug screening

    , Article Small Methods ; Volume 4, Issue 10 , 2020 Ren, L ; Zhou, X ; Nasiri, R ; Fang, J ; Jiang, X ; Wang, C ; Qu, M ; Ling, H ; Chen, Y ; Xue, Y ; Hartel, M.C ; Tebon, P ; Zhang, S ; Kim, H.-J ; Yuan, X ; Shamloo, A ; Dokmeci, M. R ; Li, S ; Khademhosseini, A ; Ahadian, S ; Sun, W ; Sharif University of Technology
    John Wiley and Sons Inc  2020
    Abstract
    Animal models and traditional cell cultures are essential tools for drug development. However, these platforms can show striking discrepancies in efficacy and side effects when compared to human trials. These differences can lengthen the drug development process and even lead to drug withdrawal from the market. The establishment of preclinical drug screening platforms that have higher relevancy to physiological conditions is desirable to facilitate drug development. Here, a heart-on-a-chip platform, incorporating microgrooves and electrical pulse stimulations to recapitulate the well-aligned structure and synchronous beating of cardiomyocytes (CMs) for drug screening, is reported. Each chip... 

    High-throughput low-complexity systolic montgomery multiplication over GF(2m) Based on Trinomials

    , Article IEEE Transactions on Circuits and Systems II: Express Briefs ; Volume 62, Issue 4 , January , 2015 , Pages 377-381 ; 15497747 (ISSN) Bayat Sarmadi, S ; Farmani, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Cryptographic computation exploits finite field arithmetic and, in particular, multiplication. Lightweight and fast implementations of such arithmetic are necessary for many sensitive applications. This brief proposed a low-complexity systolic Montgomery multiplication over GF(2m). Our complexity analysis shows that the area complexity of the proposed architecture is reduced compared with the previous work. This has also been confirmed through our application-specific integrated circuit area and time equivalent estimations and implementations. Hence, the proposed architecture appears to be very well suited for high-throughput low-complexity cryptographic applications  

    Quantifying the difference in resource demand among classic and modern NoC workloads

    , Article Proceedings of the 34th IEEE International Conference on Computer Design, ICCD 2016, 2 October 2016 through 5 October 2016 ; 2016 , Pages 404-407 ; 9781509051427 (ISBN) Mirhosseini, A ; Sadrosadati, M ; Zare, M ; Sarbazi Azad, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2016
    Abstract
    This paper quantifies the difference in resource demand between modern and classic NoC workloads. In the paper, we show that modern workloads are able to better utilize higher numbers of VCs and smaller C factors in order to attain performance and energy efficiency. This is because of the high throughput and possible local congestions in their traffic pattern. As a result, such workloads are more suitable for concurrency and redundancy energy reduction techniques where the voltage and frequency are reduced simultaneously and the increased power budget is used for introducing additional resources to the network in order to improve the performance