Loading...
Post-Fault Control of Fault-Tolerant Active Neutral Point Clamped Inverter
Bayat, Yasin | 2024
9
Viewed
- Type of Document: M.Sc. Thesis
- Language: Farsi
- Document No: 56825 (05)
- University: Sharif University of Technology
- Department: Electrical Engineering
- Advisor(s): Zolghadri, Mohammad Reza
- Abstract:
- The reliability of power converters in various applications, including industrial, military, aerospace, and commercial applications, is of great importance. For this reason, the development of fault-tolerant power converters is crucial from the perspective of system availability and the prevention of adverse consequences. Tolerating various types of faults, maintaining full output capacity after a fault, and cost-effectiveness are the primary challenges for many existing solutions. In this thesis, a fault tolerance solution is presented for a five-level active-neutral-point-clamped converter. The proposed approach enhances fault-tolerant control for the older version of this converter by adding a limited number of inexpensive components. These improvements are implemented with the help of a new control scheme. In the proposed scheme, space vector modulation is used, and by measuring the DC-link voltage and the output voltage and current of the three-phase system, additional switching states are achieved. This allows the converter to continue operating after a fault while reducing the number of output voltage levels. Simulation results conducted on a high-power version of the design demonstrate that the proposed method for the converter can achieve fault tolerance and control performance under open-circuit fault conditions. Moreover, it can maintain its nominal voltage and current even after a fault occurs. Simulation results and practical implementation on a low-power prototype confirm the effectiveness, speed, and efficiency of this proposed fault-tolerant solution in managing and controlling faults
- Keywords:
- Fault-tolerant Control ; Five-Level Converter ; Discrete Space Vector Modulation ; Active Neutral Point Clamped Converter ; Post Fault Operation
- محتواي کتاب
- view
- مقدمه
- مبدل پنج سطحی با نقطه نول مهار شدهی فعال
- تاثیر انواع خطاهای برروی عملکرد درست مبدل 5L-ANPC
- عملکرد بعد از خطای مدار باز عناصر قدرت در مبدل 5L-ANPC
- پیادهسازی مبدل 5L-ANPC
- نتیجهگیری و پیشنهادات
- مراجع
- پیوست