Loading...
Search for: shoulder-pain
0.006 seconds

    Dynamic comparison of segmentary scapulohumeral rhythm between athletes with and without impingement syndrome

    , Article Iranian Journal of Radiology ; Vol. 11, issue. 2 , 2014 Taghizadeh Delkhoush, C ; Maroufi, N ; Ebrahimi Takamjani, I ; Farahmand, F ; Shakourirad, A ; Haghani, H ; Sharif University of Technology
    Abstract
    Background: Patients who have shoulder pain usually have compensatory or contributory deviation of shoulder motion during arm elevation. In the traditional scapulohumeral rhythm, the share of the acromioclavicular (AC) and the sternoclavicular (SC) joint movements and also the role of AC internal rotation angle are unknown. Objectives: The main purpose of this study was to measure and compare the segmentary scapulohumeral rhythm (SSHR) during scapular arm elevation at a steady rotational speed in athletes with and without impingement syndrome. Patients and Methods: Using a speedometer, the maximum speed of arm elevation was measured in 21 men in each of the involved and uninvolved groups.... 

    Designing instrumented walker to measure upper-extremity’s efforts: a case study

    , Article Assistive Technology ; 2018 , Pages 1-9 ; 10400435 (ISSN) Khodadadi, M ; Arab Baniasad, M ; Arazpour, M ; Farahmand, F ; Zohoor, H ; Sharif University of Technology
    Taylor and Francis Inc  2018
    Abstract
    The high prevalence of shoulder pain in using walkers in patients who have spinal cord injury (SCI). Also, the limited options available to economically measure grip forces in walkers, which drove the need to create one. This article describes a method to obtain upper-extremities’ forces and moments in a person with SCI by designing an appropriate instrumented walker. First, since the commercial multidirectional loadcells are too expensive, custom loadcells are fabricated. Ultimately, a complete gait analysis by means of VICON motion analysis and using inverse dynamic method has been held to measure upper-extremities’ efforts. The results for a person with SCI using a two-wheel walker in low... 

    Designing instrumented walker to measure upper-extremity’s efforts: A case study

    , Article Assistive Technology ; Volume 31, Issue 5 , 2019 , Pages 267-275 ; 10400435 (ISSN) Khodadadi, M ; Baniasad, M. A ; Arazpour, M ; Farahmand, F ; Zohoor, H ; Sharif University of Technology
    Taylor and Francis Inc  2019
    Abstract
    The high prevalence of shoulder pain in using walkers in patients who have spinal cord injury (SCI). Also, the limited options available to economically measure grip forces in walkers, which drove the need to create one. This article describes a method to obtain upper-extremities’ forces and moments in a person with SCI by designing an appropriate instrumented walker. First, since the commercial multidirectional loadcells are too expensive, custom loadcells are fabricated. Ultimately, a complete gait analysis by means of VICON motion analysis and using inverse dynamic method has been held to measure upper-extremities’ efforts. The results for a person with SCI using a two-wheel walker in low...