Loading...
Search for: pipe
0.011 seconds
Total 288 records

    Exergy analysis of a flat plate solar collector in combination with heat pipe

    , Article International Journal of Environmental Research ; Vol. 8, Issue. 1 , 2014 , Pages 39-48 ; ISSN: 17356865 Kargarsharifabad, H ; Shafii, M. B ; Rahni, M. T ; Abbaspour, M ; Sharif University of Technology
    Abstract
    The use of solar collectors in combination with heat pipes is rapidly growing in recent years. Heat pipes, as heat transfer components, have undeniable advantages in comparison with other alternatives. The most important advantage is their high rate of heat transfer at minor temperature differences. Although there have been numerous studies on the heat analysis or first thermodynamic analysis of flat plate solar collectors in combination with heat pipes, the exergy analysis of these collectors is needed to be investigated. In this work, energy and exergy analysis of a flat plate solar collector with a heat pipe is conducted theoretically. Next, the exergy efficiency of pulsating heat pipe... 

    Hydraulic performance of drain pipe in a submerged tank

    , Article Urban Water Management: Challenges and Oppurtunities - 11th International Conference on Computing and Control for the Water Industry, CCWI 2011, 5 September 2011 through 7 September 2011, Exeter ; Volume 1 , 2011 ; 0953914089 (ISBN) ,9780953914081 (ISBN) Nabaei, M ; Mahmoud Borghei, S ; Sharif University of Technology
    2011
    Abstract
    The hydraulic performances of drain pipes are very important in drainage projects and systems. Usually these pipes are used in a saturated soil to decrease the water table to a favorable level or, drain the excess water. However, drain pipes can be used in a water or wastewater tank for different purposes such as selective withdrawal. There are not much published documents on the performance of drain pipes in submerged situations. Therefore, the aim of this study was to examine the performance of drain pipe in a submerged tank. For this, a horizontal pipe of 26.5 mm inner diameter, 5 meter long with 48 circular drain inlets of 10 mm diameter at equal distances along the pipe have been tested... 

    Experimental investigation of the thermal characteristics of single-turn pulsating heat pipes with an extra branch

    , Article International Journal of Thermal Sciences ; Volume 134 , 2018 , Pages 258-268 ; 12900729 (ISSN) Sedighi, E ; Amarloo, A ; Shafii, M. B ; Sharif University of Technology
    Elsevier Masson SAS  2018
    Abstract
    In addition to some approaches such as changing the working fluid or number of turns in a pulsating heat pipe (PHP), geometrical changes are also appealing for enhancing the thermal performance of this type of heat pipes. The main idea of this investigation is to increase heat transfer rate by increasing flow circulation of working fluid. By placing an additional branch in the evaporator section, a secondary bubble pump was created which improved the circulation of fluid inside PHP. In order to investigate the impact of this additional branch, two similar one-turn copper heat pipes were fabricated. One of them was the conventional PHP and the other had an additional branch and is named... 

    Experimental investigation of the effect of using thermosyphon heat pipes and vacuum glass on the performance of solar still

    , Article Energy ; Volume 75 , 2014 , pp. 501–507 ; ISSN: 03605442 Jahangiri Mamouri, S ; Gholami Derami, H ; Ghiasi, M ; Shafii, M. B ; Shiee, Z ; Sharif University of Technology
    Abstract
    A desalination system consumes energy for production of freshwater. Since the solar energy is a low-cost, environmentally clean, and available energy throughout the world, it could be the best source of energy for such systems. In this work, a modified desalination system is presented which uses advantages of thermosyphon heat pipes as a fast and high performance thermal conducting device, and at the same time, employs the advantages of evacuated tube collectors (ETCs) which are flexible and have high performance in adverse weather conditions. Results show considerable increase in the production rate of desalinated water and system efficiency with a maximum production rate of 1.02 kg/(m2 h)... 

    Ferrofluidic open loop pulsating heat pipes: Efficient candidates for thermal management of electronics

    , Article Experimental Heat Transfer ; Vol. 27, issue. 3 , Dec , 2014 , p. 296-312 ; ISSN: 08916152 Mohammadi, M ; Taslimifar, M ; Saidi, M. H ; Shafii, M. B ; Afshin, H ; Hannani, S. K ; Sharif University of Technology
    Abstract
    Thermal management of electronic devices is presently a serious concern. This article investigates the thermal performance of a five-turn open-loop pulsating heat pipe in both start-up and steady thermal conditions. The effects of working fluid, namely water and ferrofluid, heat input, charging ratio, ferrofluid concentration, orientation, as well as application of magnetic field, are explored. Experimental results show that using ferrofluid enhances the thermal performance in comparison with the case of distilled water under certain conditions. In addition, applying a magnetic field on the open-loop pulsating heat pipe charged with ferrofluid improves its thermal performance. Charging... 

    Investigating dynamic response of a buried pipeline in sandy soil layer by 1G shaking table test

    , Article International Journal of Civil Engineering ; Volume 8, Issue 2 , 2010 , Pages 107-124 ; 17350522 (ISSN) Jafarzadeh, F ; Farahi Jahromi, H ; Abazari Torghabeh, E ; Sharif University of Technology
    2010
    Abstract
    Investigating the parameters influencing the behavior of buried pipelines under dynamic loading is of great importance. In this study the soil structure interaction of the pipelines with the surrounding soil was addressed using shaking table tests. Wave propagation along the soil layers was also included in the study. The semi infinite nature of the field was simulated using a laminar shear box. The soil used in the experiments was Babolsar coastal sand (Iran). PVC pipes were used due to their analogy with the field. Eight models were constructed with the first four models having uniform base. In the next models, the non-uniformities of real ground were simulated using a concrete pedestal... 

    Experimental investigation of a novel magnetically variable conductance thermosyphon heat pipe

    , Article Applied Thermal Engineering ; Volume 126 , 2017 , Pages 1-8 ; 13594311 (ISSN) Shafii, M. B ; Ahmadi, H ; Faegh, M ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    In this study, a novel Magnetically Variable Conductance Thermosyphon Heat Pipe (MVCTHP) was investigated experimentally. The possibility of deactivating a portion of evaporator length and subsequently altering heat pipe resistance by positioning a steel ball inside the evaporator and moving it by an external magnet was studied. The effect of various ball positions in the evaporator and inclination angles on heat pipe performance was studied at 30, 60, 90 and 120 W. The results indicated that at a given heat input, moving the ball away from the beginning of the evaporator of heat pipe increases its thermal resistance. Furthermore, by increasing heat input, MVCTHP performance for various ball... 

    A review on application of nanofluid in various types of heat pipes

    , Article Journal of Central South University ; Volume 26, Issue 5 , 2019 , Pages 1021-1041 ; 20952899 (ISSN) Nazari, M. A ; Ahmadi, M. H ; Sadeghzadeh, M ; Shafii, M. B ; Goodarzi, M ; Sharif University of Technology
    Central South University of Technology  2019
    Abstract
    Nanotechnology is widely used in heat transfer devices to improve thermal performance. Nanofluids can be applied in heat pipes to decrease thermal resistance and achieve a higher heat transfer capability. In the present article, a comprehensive literature review is performed on the nanofluids’ applications in heat pipes. Based on reviewed studies, nanofluids have a high capacity to boost the thermal behavior of various types of heat pipes such as conventional heat pipes, pulsating heat pipes, and thermosyphons. Besides, it is observed that there must be a selected amount of concentration for the high-performance utilization of nanoparticles; high concentration of nanoparticles causes a... 

    Vapor flow analysis in partially-heated concentric annular heat PIPES

    , Article International Journal of Computational Engineering Science ; Volume 5, Issue 1 , 2004 , Pages 235-244 ; 14658763 (ISSN) Layeghi, M ; Nouri Borujerdi, A ; Sharif University of Technology
    Imperial College Press  2004
    Abstract
    The steady-state laminar and incompressible vapor flow in four partially-beated concentric annular beat pipe (CAHP) is studied. The governing equations are solved numerically, using finite volume approach based on collocated grids. The first order upwind scheme and the QUICK scheme are used in the numerical solution. The vapor pressure distributions and velocity profiles along the annular vapor space are predicted for a number of test cases in the range of low to moderate radial Reynolds numbers. The results show that in a partially-heated annular beat pipe, as the radial Reynolds number increases, a number of recirculation zones may be created at both ends of the evaporator and condenser... 

    Experimental investigation of thermal resistance of a ferrofluidic closed-loop pulsating heat pipe

    , Article Heat Transfer Engineering ; Vol. 35, issue. 1 , 2014 , pp. 25-33 ; ISSN: 01457632 Mohammadi, M ; Mohammadi, M ; Ghahremani, A. R ; Shafii, M. B ; Mohammadi, N ; Sharif University of Technology
    Abstract
    For the present article, a pulsating heat pipe (PHP) is fabricated and tested experimentally by bending a copper tube. The effects of working fluid, heat input, charging ratio, inclination angle, magnets location, and ferrofluid (magnetic nanofluid) volumetric concentration have been investigated on the thermal performance of this PHP. Experimental results show that using ferrofluid as a working fluid improves the thermal performance of the PHP significantly. Moreover, applying a magnetic field on a ferrofluidic PHP reduces its thermal resistance. By changing the inclination angle of the PHP from vertical mode to angles close to the horizontal mode, the present PHP has a constant and... 

    A study on seismic behavior of buried steel pipelines crossing active faults

    , Article Pipelines 2010: Climbing New Peaks to Infrastructure Reliability - Renew, Rehab, and Reinvest - Proc. of the Pipelines 2010 Conference ; Volume 386 , 2010 , Pages 1-12 ; 9780784411384 (ISBN) Bolvardi, V ; Bakhshi, A ; Sharif University of Technology
    2010
    Abstract
    Some known phenomena which cause a buried steel pipeline to fail are large ground motion and landside. Thus, many researchers have studied pipelines behavior against those phenomena with simplified assumptions in which effects of interaction between soil and pipe are not considered as well. In this study, the behavior of a pipe through Normal and Strike slip faults and contact between them are simulated close to reality with the powerful software of ABAQUS. The results from a parametric analysis on effects of those faults on buried steel pipelines show that increasing the angle between the pipe axis and fault plane (up to 90°), as well as the pipe thickness, and decreasing the burial depth... 

    Boundary control of a marine riser pipe conveying fluid

    , Article ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE) ; Vol. 4A , 2014 ; ISBN: 9780791846476 Nojoumian, M. A ; Shirazi, M. J ; Salarieh, H ; Sharif University of Technology
    Abstract
    In this paper, the model of pipe conveying fluid, like marine risers, is modeled with the effect of the interaction between the fluid and structure. A torque is assumed at one end of the pipe to control the vibration of the pipe. The stability of the pipe under time varying disturbance in forced vibration using boundary control law is proved. Exponential stability can be achieved under the free vibration condition. The proposed control law is simple and could be attained by some simple sensors at the end of the pipe. The control law is independent from system parameters so the controller is robust to disturbances and environmental conditions. The controller is obtained via a Lyapunov... 

    Experimental investigation on performance of a rotating closed loop pulsating heat pipe

    , Article International Communications in Heat and Mass Transfer ; Volume 45 , 2013 , Pages 137-145 ; 07351933 (ISSN) Aboutalebi, M ; Nikravan Moghaddam, A. M ; Mohammadi, N ; Shafii, M. B ; Sharif University of Technology
    2013
    Abstract
    Pulsating heat pipes (PHPs) are interesting heat transfer devices. Their simple, high maintaining, and cheap arrangement has made PHPs very efficient compared to conventional heat pipes. Rotating closed loop PHP (RCLPHP) is a novel kind of them, in which the thermodynamic principles of PHP are combined with rotation. In this paper, effect of rotational speed on thermal performance of a RCLPHP is investigated experimentally. The research was carried out by changing input power (from 25. W to 100. W, with 15. W steps) and filling ratio (25%, 50%, and 75%) for different rotational speeds (from 50. rpm to 800. rpm with an increment of 125. rpm). The results presented that at a fixed filling... 

    Promising technology for electronic cooling: Nanofluidic micro pulsating heat pipes

    , Article Journal of Electronic Packaging, Transactions of the ASME ; Volume 135, Issue 2 , 2013 ; 10437398 (ISSN) Jahani, K ; Mohammadi, M ; Shafii, M. B ; Shiee, Z ; Sharif University of Technology
    2013
    Abstract
    Currently, the thermal management of microelectromechanical systems (MEMS) has become a challenge. In the present research, a micro pulsating heat pipe (MPHP) with a hydraulic diameter of 508 lm, is experimented. The thermal performance of the MPHP in both the transient and steady conditions, the effects of the working fluid (water, silver nanofluid, and ferrofluid), heating power (4, 8, 12, 16, 20, 24, and 28 W), charging ratio (20, 40, 60, and 80%), inclination angle (0 deg, 25 deg, 45 deg, 75 deg, and 90 deg relative to horizontal axis), and the application of magnetic field, are investigated and thoroughly discussed. The experimental results show that the optimum charging ratio for water... 

    Effects of anti-vortex plates on air entrainment by free vortex

    , Article Scientia Iranica ; Volume 20, Issue 2 , 2013 , Pages 251-258 ; 10263098 (ISSN) Kabiri Samani, A. R ; Borghei, S. M ; Sharif University of Technology
    2013
    Abstract
    Free surface vortex and air entrainment are not favorable experiences in hydropower and pumping projects. While complete omission of vortex and air entrainment is not always cost effective, partially weakened free-surface vortex flow is more economical and practical. Hence, in this study, a comprehensive set of experiments were conducted to partially reduce vortex strength and air entrainment at vertical pipe intakes, using rectangular anti-vortex plates. This phenomenon results in increasing water discharge compared with a corresponding free-surface vortex for the same water depth, i.e. in cases of shaft spillway. The plates were used as singles and in pairs and placed symmetrically and... 

    Thermal performance of an open loop pulsating heat pipe with ferrofluid (Magnetic Nano-Fluid)

    , Article ASME 2012 3rd International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2012 ; 2012 , Pages 185-190 ; 9780791854778 (ISBN) Taslimifar, M ; Mohammadi, M ; Saidi, M. H ; Afshin, H ; Shafii, M. B ; Kazemzadeh Hannani, S ; Sharif University of Technology
    Abstract
    In the present research an experimental investigation is performed to explore the effects of working fluid, heat input, ferrofluid concentration, magnets location, and inclination angle on the thermal performance of an Open Loop Pulsating Heat Pipe (OLPHP). Obtained results show that using ferrofluid can improve the thermal performance and applying a magnetic field on the water based ferrofluid decreases the thermal resistance. It shows that at an inclination angle of the OLPHP to be zero, the thermal performance of the present OLPHP reduces. Best heat transfer capability was achieved at 67.5 degree relative to horizontal axis for all of working fluids. Variation of the magnets location... 

    Experimental study of the startup performance of ferrofluidic open loop Pulsating Heat Pipes

    , Article ASME 2012 Heat Transfer Summer Conference Collocated with the ASME 2012 Fluids Engineering Div. Summer Meeting and the ASME 2012 10th Int. Conf. on Nanochannels, Microchannels and Minichannels, HT 2012, Rio Grande, 8 July 2012 through 12 July 2012 ; Volume 2 , 2012 , Pages 585-591 ; 9780791844786 (ISBN) Maziar, M ; Mehdi, T ; Siamak, K. H ; Mohammad Hassan, S ; Hossein, A ; Mohammad Behshad, S ; Sharif University of Technology
    2012
    Abstract
    Pulsating Heat Pipes (PHPs) are new and promising heat transfer devices. To implement the novel idea to vary the startup performance of a PHP using ferrofluid with and without the application of magnetic field, an experimental investigation is conducted. The effects of several important parameters including working fluid, charging ratio, heat input, ferrofluid concentration, internal pressure, and application of magnetic field on the startup performance of Open Loop Pulsating Heat Pipes (Open Loop PHPs) have been considered and described in detail. Obtained results show that using ferrofluid instead of distilled water can improve the startup performance of PHPs in certain conditions.... 

    Experimental study of the effects of ferrofluid on thermal performance of a pulsating heat pipe

    , Article ASME 2011 9th International Conference on Nanochannels, Microchannels, and Minichannels, ICNMM 2011 ; Volume 1 , 2011 , Pages 435-440 ; 9780791844632 (ISBN) Maziar, M ; Mohammad, M ; Amir, R. G ; Shafii, M. B ; Sharif University of Technology
    2011
    Abstract
    In this work, a four-turn Pulsating Heat Pipe (PHP) is fabricated and tested experimentally. The novelty of the present PHP is the capability of obtaining various thermal performances at a specific heat input by changing the magnetic field. The effects of working fluid (water and ferrofluid), charging ratio (25%, 40%, and 55%), heat input (25, 35, 45, 55, 65, 75, and 85 W), orientation (vertical and horizontal heat mode), and magnetic field on the thermal performance of PHPs are investigated. The results showed that applying the magnetic field on the water based ferrofluid reduced the thermal resistance of PHP by a factor of 40.5% and 38.3% in comparison with the pure water case for the... 

    Experimental investigation of nanofluid stability on thermal performance and flow regimes in pulsating heat pipe

    , Article Journal of Thermal Analysis and Calorimetry ; 25 May , 2018 , Pages 1-13 ; 13886150 (ISSN) Akbari, A ; Saidi, M. H ; Sharif University of Technology
    Springer Netherlands  2018
    Abstract
    Pulsating heat pipe (PHP) is a type of wickless heat pipe that has a simple structure and an outstanding thermal performance. Nanofluid is a type of fluid in which nanoparticles are dispersed in a base fluid and have generally a better thermal conductivity in comparison with its base fluid. In this article, the performance of a nanofluid PHP is investigated. Graphene/water nanofluid with a concentration of 1 mg mL−1 and TiO2 (titania)/water nanofluid with a concentration of 10 mg mL−1 are used as the working fluids. To simultaneously investigate the thermal performance and flow regimes in the PHP, a one-turn copper PHP with a Pyrex glass attached to its adiabatic section is used. A one-turn... 

    Experimental investigation of nanofluid stability on thermal performance and flow regimes in pulsating heat pipe

    , Article Journal of Thermal Analysis and Calorimetry ; Volume 135, Issue 3 , 2019 , Pages 1835-1847 ; 13886150 (ISSN) Akbari, A ; Saidi, M. H ; Sharif University of Technology
    Springer Netherlands  2019
    Abstract
    Pulsating heat pipe (PHP) is a type of wickless heat pipe that has a simple structure and an outstanding thermal performance. Nanofluid is a type of fluid in which nanoparticles are dispersed in a base fluid and have generally a better thermal conductivity in comparison with its base fluid. In this article, the performance of a nanofluid PHP is investigated. Graphene/water nanofluid with a concentration of 1 mg mL −1 and TiO 2 (titania)/water nanofluid with a concentration of 10 mg mL −1 are used as the working fluids. To simultaneously investigate the thermal performance and flow regimes in the PHP, a one-turn copper PHP with a Pyrex glass attached to its adiabatic section is used. A...