    Fault-tolerant five-leg converter topology with FPGA-Based reconfigurable control

    , Article IEEE Transactions on Industrial Electronics ; Volume 60, Issue 6 , 2013 , Pages 2284-2294 ; 02780046 (ISSN) Shahbazi, M ; Poure, P ; Saadate, S ; Zolghadri, M. R ; Sharif University of Technology
    2013
    Abstract
    Fast fault detection and reconfiguration of power converters is necessary in electrical drives to prevent further damage and to make the continuity of service possible. On the other hand, component minimized converters may provide the benefits of higher reliability and less volume and cost. In this paper, a new fault-tolerant converter topology is studied. This converter has five legs before the fault occurrence, and after fault detection the converter continues to function with four legs. A very fast fault detection and reconfiguration scheme is presented and studied. Simulations and experimental tests are performed to evaluate the structure requirements, the digital reconfigurable... 

    Fast detection of open-switch fault in cascaded H-Bridge multilevel converter

    , Article 6th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2015, 3 February 2015 through 4 February 2015 ; February , 2015 , Pages 538-543 ; 9781479976539 (ISBN) Shahbazi, M ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Cascaded H-Bridge converter has recently been utilized in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power switch fault detection method is presented to identify the fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is easy for implementation on an FPGA device, due to the use of simple math, relational and state machine blocks. The proposed method is verified by computer... 

    Fast detection of open-switch fault in cascaded H-bridge multilevel converter

    , Article Scientia Iranica ; Volume 25, Issue 3D , 2018 , Pages 1561-1570 ; 10263098 (ISSN) Shahbazi, M ; Zolghadri, M. R ; Khodabandeh, M ; Ouni, S ; Sharif University of Technology
    Sharif University of Technology  2018
    Abstract
    Cascaded H-bridge converter has been utilized recently in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power-switch fault detection method is presented to identify a fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is suitable for implementation on an FPGA device due to the use of simple math, relational, and state machine blocks. The proposed method is verified by computer...