Loading...
Search for: neurosurgical-procedures
0.009 seconds

    Minimization of target registration error for vertebra in image-guided spine surgery

    , Article International Journal of Computer Assisted Radiology and Surgery ; Vol. 9, issue. 1 , January , 2014 , p. 29-38 Ershad, M ; Ahmadian, A ; Dadashi Serej, N ; Saberi, H ; Amini Khoiy, K ; Sharif University of Technology
    Abstract
    Purpose: The accuracy of pedicle screw placement during image-guided spine surgery (IGSS) can be characterized by estimating the target registration error (TRE). The major factors that influence TRE were identified, minimized, and verified with in vitro experiments. Materials and methods: Computed-tomography- compatible markers are placed over anatomical landmarks of lumbar vertebral segments in locations that are feasible and routinely used in surgical procedures. TRE was determined directly for markers placed on the pedicles of vertebra segments. First, optimum selections of landmarks are proposed for different landmarks according to the minimum achievable TRE values in different...