Loading...
Search for: glassy-carbon-electrodes
0.01 seconds
Total 60 records

    Modification of a glassy carbon electrode with a bilayer of multiwalled carbon nanotube/benzene disulfonate-doped polypyrrole: Application to sensitive voltammetric determination of olanzapine

    , Article RSC Advances ; Vol. 4, Issue. 76 , Aug , 2014 , pp. 40553-40560 ; ISSN: 20462069 Shahrokhian, S ; Azimzadeh, M ; Hosseini, P ; Sharif University of Technology
    Abstract
    A glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes and subsequently was electro-polymerized with polypyrrole. The prepared electrode was used for the voltammetric determination of olanzapine (OLZ). The peak current of OLZ increases remarkably on the surface of the modified electrode. This is due to the large increase in the microscopic area of the electrode surface along with the strong adsorption of OLZ on the surface of the electrode. The film modifier was characterized by scanning electron microscopy, atomic force microscopy and cyclic voltammetry techniques. Experimental variables, such as deposited amount of nanotube suspension, pH of the supporting... 

    Direct electron transfer of myoglobin on CdO nanoparticles modified glassy carbon electrode

    , Article International Journal of Electrochemical Science ; Volume 8, Issue 5 , 2013 , Pages 7345-7356 ; 14523981 (ISSN) Mohammadi, N ; kakavandi, Y. G ; Movassagh, A. A ; Nasereslami, S ; Mohseni, G ; Hajiosseinlo, A ; Sofimaryo, L ; Soleimani, R ; Akbari-dastjerdi, H ; Negahdary, M ; Sharif University of Technology
    2013
    Abstract
    In this study, direct electron transfer of myoglobin (Mb) on cadmium oxide (CdO) nanoparticles modified glassy carbon electrode (GCE) was investigated. Prepared CdO nanoparticles were studied by X-Ray diffraction (XRD) and UV-visible absorption methods. All electrochemical studies were performed by cyclic voltammetry (CV) and a potentiostat device. The cyclic voltammogram of Mb/ CdO Nps/ GCE showed a couple of stable redox and oxidative peaks at -470 and -370 mV at scan rate of 50 mVs-1, respectively. The formal potential (Eo) of myoglobin was calculated as -(420 ± 3) mV. Direct electrode transfer led to design a biosensor for determination of hydrogen peroxide (H2O2). The sensor sensitivity... 

    Electrochemical oxidation mechanisms of the antioxidants daidzein and 7-Hydroxy-4-chromone

    , Article Electroanalysis ; Volume 24, Issue 3 , 2012 , Pages 618-626 ; 10400397 (ISSN) Fernandes, I. P. G ; Oliveira, S. C. B ; Ghalkhani, M ; Shahrokhian, S ; Oliveira Brett, A. M ; Sharif University of Technology
    Abstract
    The electrochemical behavior of antioxidants daidzein (DZ) and 7-hydroxy-4-chromone (7-OH-4-CHM) was investigated. The oxidation of DZ is irreversible, pH-dependent, and occurs in two steps, the first of 4′-OH on the B-ring and the second on the 7-OH on the A-ring. The oxidation of 7-OH-4-CHM occurs on the 7-OH on the A-ring, is irreversible, pH-dependent and proceeds in a single step. The DZ diffusion coefficient was calculated in pH7.0 phosphate buffer to be D DZ=8.1×10 -5cm 2s -1. The detection limits of DZ and 7-OH-4-CHM was calculated as LOD DZ=0.08μM and LOD 7-OH-4-CHM=0.13μM  

    Preparation and Investigation of the Electrochemical of the Glassy Carbon Electrode Modified by Nanocellulose/Carbon Nanoparticle: Application to Pharmaceutical Determinations

    , M.Sc. Thesis Sharif University of Technology Balotf, Hamed (Author) ; Shahrokhian, Saeed (Supervisor)
    Abstract
    In the first part, a novel electrochemical sensor for clonazepam (CLNP) was fabricated based on immobilizing cellulose nanofibers /carbon nanoparticles (CNFs/CNPs) nanocomposite on glassy carbon electrode (CNFs/CNPs/GCE). The combination of CNFs and CNPs produced a novel kind of structurally uniform and electro-analytically active nanocomposite. The surface morphology of CNFs/CNPs layer deposited onto glassy carbon electrode was characterized by scanning electron microscopy. The results of the voltammetric investigations showed a considerable enhancement in the cathodic peak current of CLNP (up to 60 times) on the surface of CNFs/CNPs/GCE relative to the bare GCE. Under the optimal... 

    Preparation and Investigation of the Electrochemical Behavior of Sensors Based on Glassy Carbon Electrode Modified with Various Carbon Nanostructures Decorated by Some of Metal Nanoparticlesfor Determination of Ceftizoxime

    , M.Sc. Thesis Sharif University of Technology Ranjbar, Saba (Author) ; Shahrokhian, Saeed (Supervisor) ; Masoumeh Ghalkhani (Co-Advisor)
    Abstract
    In the recent years, sensors and biosensors attracts much attentions as a suitable devices in analytical chemistry. In this meantime carbon nanostructures and metal nanoparticles act as a good choice owing to their unique properties such as high electrical conductivity andmechanical and chemical stability in modification of the surface of sensors and biosensors. Because of importance of analysis the trace amounts of pharmaceutical and biological compounds, in this studies the surface of glassy carbon electrode was modified with some carbon nanostructures and metal nanoparticles for electrochemical investigation and determination of pharmaceutical and clinical compounds.In the first work, a... 

    Fabrication of Applied Electrode Materials based on Metal-Organic Frameworks to Design Non-Enzymatic Electrochemical Sensing Platforms for Measuring of Glucose in Physiological Samples

    , M.Sc. Thesis Sharif University of Technology Ezzati, Milad (Author) ; Shahrokhian Dehkordi, Saeed (Supervisor)
    Abstract
    In the first work, the method of direct growth was used to grew MOFs based on cobalt, as electroactive centers, for preparing electrochemical sensors for the determination of glucose. In comparison to most of the electrochemical sensing platforms based on MOFs for determining glucose, which suffer from some disadvantages like time-consuming synthesis procedures and using hazardous organic solvents, the proposed in situ growth method is much faster and no need to toxic organic solvents. Herein, cobalt-based MOFs were grown on the surface of the reduced graphene oxide modified glassy carbon electrode by the direct and rapid conversion of cobalt hydroxide nanosheets intermediates. The... 

    Fabrication of Composite Electrode Materials Based on Bi-Metalic Metal-Organic Frameworks for Designation of Amperometric Non-Enzymatic Glucose Sensors

    , M.Sc. Thesis Sharif University of Technology Ataei Kachouei, Matin (Author) ; Shahrokhian, Saeed (Supervisor)
    Abstract
    In the present study, the method of direct growth was used to grew bi-metalic MOFs based on cobalt and zinc, as electroactive centers, for preparing electrochemical sensors for the determination of glucose. In comparison to most of the electrochemical sensing platforms based on MOFs for determining glucose, which suffer from some disadvantages like time-consuming synthesis procedures and using hazardous organic solvents, the proposed in-situ growth method is much faster and without any need to toxic organic solvents. Herein, cobalt and zinc-based MOFs were grown on the surface of glassy carbon electrode by the direct and rapid conversion of layered double hydroxide nanosheets intermediates.... 

    A comparative investigation of the electrocatalytic oxidation of methanol on poly-NiTCPP and poly-TCPP/Ni modified glassy carbon electrodes

    , Article Journal of Electroanalytical Chemistry ; Volume 663, Issue 1 , December , 2011 , Pages 14-23 ; 15726657 (ISSN) Jafarian, M ; Haghighatbin, M. A ; Gobal, F ; Mahjani, M. G ; Rayati, S ; Sharif University of Technology
    2011
    Abstract
    Electro-oxidation of methanol in alkaline solution at a glassy carbon electrode electrochemically modified by a conductive polymeric meso-tetra(4-carboxyphenyl)porphyrinato nickel(II), abbreviated as poly-NiTCPP and also meso-tetra(4-carboxyphenyl)porphyrin with incorporated nickel(II) cations, abbreviated as, poly-TCPP/Ni, were investigated and compared. Both films were prepared by oxidative electro-polymerization of complexes by repetitive cyclic voltammetry (RCV) in 0.1 M NaOH aqueous solution. The electrochemical properties and behaviors and also kinetic values of both films have been characterized and compared using cyclic voltammetry (CV), chronoamperometry (CA) and electrochemical... 

    Silver nanowires immobilized on gold-modified glassy carbon electrode for electrochemical quantification of atorvastatin

    , Article Journal of Electroanalytical Chemistry ; Volume 876 , November , 2020 Naseri, A ; Hormozi Nezhad, M. R ; Shahrokhian, S ; Asadian, E ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Development of simple yet precise sensing platforms for rapid determination of biological species and drugs is of paramount importance, not only for analysis of pharmaceutical formulations during the production stage, but also in clinical practices and medical diagnosis. In the present research, we report on the electrochemical determination of atorvastatin (ATOR) by using silver nanowires/gold-modified glassy carbon electrode (Ag NWs/Au/GCE). The modified electrode was constructed through a two-step procedure in which narrow silver nanowires synthesized via a polyol method are drop casted on a pre-modified GCE with electrodeposited gold particles. The results of XRD analysis indicated the... 

    Design and Fabrication of Advanced Electrode Materials Based on Metal-organic Frameworks and Double Layered Hydroxides Using Hollow Copper Hydroxide Nanotubes Scaffold; Application to Nonenzymatic Glucose Sensor

    , M.Sc. Thesis Sharif University of Technology Khaki Sanati, Elnaz (Author) ; Shahrokhian, Saeed (Supervisor)
    Abstract
    One of the remarkable subject in advanced electrochemistry is, design and architecting new advanced materials with new electrochemical capabilities. One of the notable capabilities is electrocatalysis. Extensive researches are carrying out into the design and preparation of electrocatalyst materials to take advantage of these materials in fabrication of electrochemical sensors and storage/conversion devices. In this field nonoporous materials attracted a lot of attentions due to their unique features. In order to make use of the nanoporous materials as the electrocatalysts, these materials must be fabricated into continuous supported thin films on the electrode surface, which is the... 

    Preparation of Nanocomposites Consisting of Nickel Oxide Nanostructures Grown on Hollow Carbon Nanospheres and Evaluation of their Ability for Electrooxidation of Hydrazine Hydrate

    , M.Sc. Thesis Sharif University of Technology Taghaddosi, Sanaz (Author) ; Shahrokhian Dehkordi, Saeed (Supervisor)
    Abstract
    In the present work, nanocomposites consisting of nickel oxide nanostructures and a hollow carbon substrate were used to modify a glassy carbon electrode's surface for the electrooxidation of hydrazine hydrate. For this purpose, hollow carbon nanospheres were first synthesized using aniline and pyrrole copolymerization process without any template needing. The hollow carbon nanospheres prepared by this method have outstanding features such as high specific surface area and good stability. On the other hand, they did not require toxic and environmentally harmful solvents to remove the template. In this study, after preparing hollow carbon nanospheres as a suitable substrate, different... 

    Constructing and Investigation of the Electrochemical Behavior of Nanocomposite of Conducting Polymers on Copper Hydroxide Nanotubes; Application to Determination of Glucose

    , M.Sc. Thesis Sharif University of Technology Manafi, Reza (Author) ; Shahrokhian, Saeed (Supervisor)
    Abstract
    A novel amperometric non-enzymatic glucose (NEG) sensor is designed by a facile preparation method. It is made by electrodeposition of Cu clusters and converting them to Cu(OH)2 nanotubes (Cu(OH)2NTs) arrays along with thin-film electro-polymerized of spindle-shaped polypyrrole (PPy@Cu(OH)2NTs), which have been doped by using sodium Benzene-1,3- disulfonate as an anion dopant. The electrochemical performance of the modified electrode toward glucose detection is investigated by various electrochemical methods. Under the optimized conditions, a significant electrochemical response improvement is observed toward the electro-oxidation of glucose on the surface of PPy@Cu(OH)2NTs electrode... 

    Design and Fabrication Nanocomposite Modified Electrode Materials Based on Transition Metal Phosphide Using Copper Hydroxide Nanotubes as a Catalytic Substrate for Glucose Sensing in Non-Enzymatic Sensors

    , M.Sc. Thesis Sharif University of Technology Kazemi Abatari, Zeynab (Author) ; Shahrokhian, Saeed (Supervisor)
    Abstract
    In this study, transition metal phosphide, with a high accessible surface and abundant electroactive centers, was used as an electrocatalyst to fabrication an electrochemical sensor of Gloucose. The direct growth of thin film of nanocomposite can be considered as an efficient method to modify the electrode surface, and the application of these modified electrodes as electrochemical sensors. nanocomposite of transition metal phosphide (CuCoP) were directly grown on Cu(OH)2 nanotubes (as-prepared on GCE) in order to design hierarchical core-shell nanostructure with using efficient, inexpensive and fast method. Here, Cu(OH)2 nanotubes not only served as substrate, but also steer the CuCoP to... 

    Construction of Pt nanoparticle-decorated graphene nanosheets and carbon nanospheres nanocomposite-modified electrodes: Application to ultrasensitive electrochemical determination of cefepime

    , Article RSC Advances ; Volume 4, Issue 15 , 2014 , Pages 7786-7794 ; ISSN: 20462069 Shahrokhian, S ; Hosseini Nassab, N ; Ghalkhani, M ; Sharif University of Technology
    Abstract
    A novel ultrasensitive modified electrode was fabricated with a graphene nanosheets and carbon nanospheres (GNS-CNS)-based nanocomposite film as a powerful platform. Pt nanoparticles (PtNPs) were simply electrodeposited onto the GNS-CNS-coated glassy carbon electrode creating a PtNPs/GNS-CNS hybrid nanocomposite modified electrode. Scanning electron microscopy, energy dispersive X-ray spectroscopy and linear sweep voltammetry (LSV) techniques were used for the characterization of the prepared modified electrode. The results of investigation of electrochemical response characteristics of cefepime (CP) revealed a considerable improvement in the oxidation peak current of CP on PtNPs/GNS-CNS/GCE... 

    Ultra-sensitive detection of leukemia by graphene

    , Article Nanoscale ; Vol. 6, issue. 24 , Dec , 2014 , p. 14810-14819 Akhavan, O ; Ghaderi, E ; Hashemi, E ; Rahighi, R ; Sharif Universit of Technology
    Abstract
    Graphene oxide nanoplatelets (GONPs) with extremely sharp edges (lateral dimensions ∼20-200 nm and thicknesses <2 nm) were applied in extraction of the overexpressed guanine synthesized in the cytoplasm of leukemia cells. The blood serums containing the extracted guanine were used in differential pulse voltammetry (DPV) with reduced graphene oxide nanowall (rGONW) electrodes to develop fast and ultra-sensitive electrochemical detection of leukemia cells at leukemia fractions (LFs) of ∼10-11 (as the lower detection limit). The stability of the DPV signals obtained by oxidation of the extracted guanine on the rGONWs was studied after 20 cycles. Without the guanine extraction, the DPV peaks... 

    Adsorptive stripping differential pulse voltammetric determination of mebendazole at a graphene nanosheets and carbon nanospheres/chitosan modified glassy carbon electrode

    , Article Sensors and Actuators, B: Chemical ; Volume 185 , 2013 , Pages 669-674 ; 09254005 (ISSN) Ghalkhani, M ; Shahrokhian, S ; Sharif University of Technology
    2013
    Abstract
    For the first time graphene nanosheets and carbon nanospheres/chitosan (GNS-CNS/CS) based nanocomposite film modified electrode was used for the electro-oxidation of mebendazole (MD). MD is a benzimidazole drug that is used to treat human infections caused by parasitic worms. MD causes slow immobilization and death of the worms by selectively and irreversibly blocking uptake of glucose. The electrochemical behavior of MD at GNS-CNS/CS modified glassy carbon electrode has been investigated using cyclic and differential pulse voltammetry in aqueous media at different pHs. The prepared electrode showed an excellent electrochemical activity toward the electro-oxidation of MD leading to a... 

    Application of glassy carbon electrode modified with a carbon nanoparticle/melamine thin film for voltammetric determination of raloxifene

    , Article Journal of Electroanalytical Chemistry ; Volume 780 , 2016 , Pages 126-133 ; 15726657 (ISSN) Shahrokhian, S ; Ghalkhani, M ; Balotf, H ; Salimian, R ; Sharif University of Technology
    Elsevier B.V  2016
    Abstract
    As a selective estrogen receptor modulator, raloxifene (RXF) prevent of osteoporosis in postmenopausal women by estrogenic actions on bone and decreases the risk of invasive breast cancer by anti-estrogenic actions on the breast and uterus tissue. However, RXF may increase the risk of blood clots, including deep vein thrombosis and pulmonary embolism. For the first time glassy carbon electrode modified with a thin film of melamine/carbon nanoparticles (CNPs/Mela) was constructed and used for the sensitive voltammetric determination of RXF. In comparison with unmodified electrode, the presence of the CNPs/Mela film resulted in a remarkable increase in the peak currents and sharpness of the... 

    Glassy carbon electrode modified with 3D graphene–carbon nanotube network for sensitive electrochemical determination of methotrexate

    , Article Sensors and Actuators, B: Chemical ; Volume 239 , 2017 , Pages 617-627 ; 09254005 (ISSN) Asadian, E ; Shahrokhian, S ; Iraji Zad, A ; Ghorbani Bidkorbeh, F ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    In the present study, a 3D porous graphene-carbon nanotube (G-CNT) network is successfully constructed on the surface of glassy carbon electrode (GCE) by electrochemical co-deposition from a concentrated graphene dispersion. The large accessible surface area provided by the interpenetrated graphene backbone in one hand and the enhanced electrical conductivity of the 3D network by incorporating CNTs on the other hand, dramatically improved the electrochemical performance of GCE in determination of Methotrexate (MTX) as an important electroactive drug compound. Under the optimum conditions, the electrode modification led to a significant increase in the anodic peak current (∼25 times) along... 

    Electrochemical deposition of gold nanoparticles on carbon nanotube coated glassy carbon electrode for the improved sensing of tinidazole

    , Article Electrochimica Acta ; Volume 78 , September , 2012 , Pages 422-429 ; 00134686 (ISSN) Shahrokhian, S ; Rastgar, S ; Sharif University of Technology
    2012
    Abstract
    The electrochemical reduction of tinidazole (TNZ) is studied on gold-nanoparticle/carbon-nanotubes (AuNP/CNT) modified glassy carbon electrodes using the linear sweep voltammetry. An electrochemical procedure was used for the deposition of gold nanoparticles onto the carbon nanotube film pre-cast on a glassy carbon electrode surface. The resulting nanoparticles were characterized by scanning electron microscopy and cyclic voltammetry. The effect of the electrodeposition conditions, e.g., salt concentration and deposition time on the response of the electrode was studied. Also, the effect of experimental parameters, e.g., potential and time of accumulation, pH of the buffered solutions and... 

    Amine functionalized TiO2 coated on carbon nanotube as a nanomaterial for direct electrochemistry of glucose oxidase and glucose biosensing

    , Article Journal of Molecular Catalysis B: Enzymatic ; Volume 68, Issue 2 , 2011 , Pages 206-210 ; 13811177 (ISSN) Tasviri, M ; Rafiee Pour, H. A ; Ghourchian, H ; Gholami, M. R ; Sharif University of Technology
    Abstract
    A nano-composite material consisting of amine functionalized TiO 2-coated carbon nanotubes was prepared and used for glucose oxidase (GOx) absorption. The GOx bearing nanomaterial was fixed on a glassy carbon electrode to construct a novel biosensor for glucose determination. The direct electrochemistry of immobilized GOx and its electron transfer parameters at the modified glassy carbon electrode were reported. The apparent heterogeneous electron transfer rate constant (ks) of GOx was estimated to be 3.5 s-1, which is higher than those reported previously. Amperometric detection of glucose resulted in a rapid (3 s) and stable response in the linear concentration range from 1.8 to 266 μM....