Loading...
Search for: flow-mediated-dilation
0.008 seconds

    Flow mediated dilation with photoplethysmography as a substitute for ultrasonic imaging

    , Article Physiological Measurement ; Volume 36, Issue 7 , 2015 , Pages 1551-1571 ; 09673334 (ISSN) Mashayekhi, G ; Zahedi, E ; Movahedian Attar, H ; Sharifi, F ; Sharif University of Technology
    Institute of Physics Publishing  2015
    Abstract
    Flow mediated dilation (FMD) is a non-invasive method for endothelial function assessment providing an index extracted from ultrasonic B-mode images. Although utilized in the research community, the difficulty of its application and high cost of ultrasonic devices prevent it from being widely used in clinical settings. In this study we show that substituting the ultrasonic device with more easily handled and low cost photoplethysmography and electrocardiography is possible. We introduce new indices based on the photoplethysmogram (PPG) and electrocardiogram (ECG) and show that they are correlated with the ultrasound-based FMD Index. To this end, a conventional ultrasound FMD test was carried... 

    Evaluation of endothelial response to reactive hyperaemia in peripheral arteries using a physiological model

    , Article International Journal of Biomedical Engineering and Technology ; Volume 33, Issue 4 , 2020 , Pages 305-324 Parsafar, M. H ; Zahedi, E ; Vahdat, B. V ; Sharif University of Technology
    Inderscience Publishers  2020
    Abstract
    Non-invasive measurement of flow-mediated dilation (FMD) in the brachial artery for assessing endothelial function is costly and operator-dependent, limiting its application to research cases. In this paper, an approach based on a physiological model between normalized central blood pressure and finger photoplethysmogram is presented. Baseline model parameters are estimated using a genetic algorithm in 30 subjects consisting of ten normal blood pressure (BP), ten high-BP and ten elderly volunteers. Beat-to-beat fitness values after reactive hyperaemia are calculated using baseline (before cuff occlusion) data. Results show that stimulus-induced changes are fairly described with a first order... 

    Meaurement of Flow Mediated Dilation Using Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Goldoozian, Layli Sadat (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Endothelial cells cover the inner surface of blood vessels. In response to different physical (such as reactive hyperemia-RH) and pharmacological stimuli, they maintain homeostasis by changing the vascular diameter (by releasing chemical agents like nitric oxide). The endothelium inability to respond to metabolic need (endothelial dysfunction) is an early marker of cardiovascular diseases such as atherosclerosis. Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmographic (PPG) signal changes... 

    Prediction of Coronary Angiography Results by Flow Mediated Dilation Assessments with Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Hosseini, Zahra Sadat (Author) ; Zahedi, Edmond (Supervisor) ; Fakhrzadeh, Hossein (Supervisor)
    Abstract
    Cardio Vascular Diseases (CVD) is currently the most important cause of mortality in the world. Coronary artery disease (CAD-with 3 major epicardial vessels) is one of the significant CVD. Coronary angiography remains the gold standard for identifying the presence and absence of stenosis due to CAD. It is performed by inserting a catheter into the coronary artery, directly injecting radiopaque contrast material there and recording radiographic images in different view of arteries. Images of this invasive way show severity and area of stenosis.
    A sign of CAD is endothelial dysfunction (inner artery layer) in peripheral arteries like the brachial artery. Due to a significant correlation... 

    Analyzing the Endothelial Function by Means of Photoplethysmogram Signal Modeling

    , M.Sc. Thesis Sharif University of Technology Amiri, Mina (Author) ; Zahedi, Edmond (Supervisor) ; Behnia, Fereidoon (Supervisor)
    Abstract
    The endothelial (the artery inner lumen cells) function is associated with cardiovascular risk factors. Its assessment methods can be classified into the two groups of invasive and noninvasive ones. The most widely used method among the current non-invasive tests employed in research settings is flow-mediated dilation (FMD). This technique measures endothelial function by inducing reactive hyperemia via the temporary arterial occlusion and measuring the resultant relative increase in the blood vessel diameter via ultrasound. The high price and large size of the device, and being operator dependent are the limitation of this method. In this work, we propose using the photoplethysmogram (PPG)... 

    Modeling the Endothelial Function in the Brachial Artery Using Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Mashayekhi, Ghoncheh (Author) ; Zahedi, Edmond (Supervisor) ; Jahed, Mehran (Supervisor)
    Abstract
    Flow Mediated Dilation (FMD) is a non-invasive method for endothelial function assessment providing an index extracted from ultrasonic B-mode images. Although utilized in the research community, the difficulty of its application and high cost of ultrasonic device prevent it from being widely used in clinical settings. In this study we show that substituting the ultrasonic device with more easily handled and low cost photoplethysmography and electrocardiography is possible. We introduce new indices based on the photoplethysmogram (PPG) and electrocardiogram (ECG) and show that they are correlated with the ultrasound-based FMD index. To this end, conventional ultrasound FMD test was carried... 

    Electrical analog model of arterial compliance during reactive hyperemia

    , Article 2011 1st Middle East Conference on Biomedical Engineering, MECBME 2011, 21 February 2011 through 24 February 2011, Sharjah ; 2011 , Pages 49-53 ; 9781424470006 (ISBN) Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    2011
    Abstract
    Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog... 

    Development of a Wrist PPG Probe for the Measurement of Radial Artery Diameter

    , M.Sc. Thesis Sharif University of Technology Keikhosravi, Adib (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Inability of endothelial cells in responding to metabolic needs (endothelial dysfunction,) is a sign of heart diseases like atherosclerosis and vascular stenosis. Recently, a new method using finger PPG signal has been proposed to determine endothelial function in response to reactive hypertension (RH.) PPG-based endothelial function assessment results are not fully correlated with ultrasound FMD tests, and this is because of some auto-regulation phenomena in the fingertip. It is expected that such problems will not exist in larger arteries, like the radial artery. The goal of this project is to acquire the PPG signal from the radial artery as it is proportional to blood volume changes in... 

    Modeling the Relationship between Central Aortic Pressure and Radial Photoplethysmogram in Flow-mediated Dilation Test

    , Ph.D. Dissertation Sharif University of Technology Parsafar, Mohammad Habib (Author) ; Vosughi Vahdat, Bijan (Supervisor) ; Zahedi, Edmond (Supervisor)
    Abstract
    According to the World Health Organization, about 35% of deaths worldwide are due to cardiovascular diseases, therefore the evaluation of vascular endothelial function has great prognostic and diagnostic value for cardiovascular diseases. The conventional noninvasive method for endothelial function evaluation is the measurement of flow-mediated dilation in brachial artery using ultrasound imaging (FMD-US). As the accuracy of FMD-US depends on the operator's skill and the resolution of the ultrasound images, this method has not been adopted. In this work, we propose to use a low cost, easily-accessible surrogate signal, the photoplethysmogram (PPG) to implement the FMD test. Whereas previous... 

    Discrimination of bilateral finger photoplethysmogram responses to reactive hyperemia in diabetic and healthy subjects using a differential vascular model framework

    , Article Physiological Measurement ; Volume 34, Issue 5 , 2013 , Pages 513-525 ; 09673334 (ISSN) Keikhosravi, A ; Aghajani, H ; Zahedi, E ; Sharif University of Technology
    2013
    Abstract
    Endothelial dysfunction assessment has received considerable attention due to its potential in early screening of cardiovascular diseases. Since the seminal work by Celermajer in flow-mediated dilation (FMD) based on B-mode ultrasound measurement of the brachial artery dilation following limb ischemia, many attempts have been made toward applying this method to clinical, non-invasive endothelial dysfunction assessment. One major obstacle toward achieving this objective has been the relative high cost of the required setup and skilled manpower. Such limitations have prompted the investigation of other non-invasively accessible signals such as the photoplethysmogram (PPG) in relation to FMD.... 

    Effect of dyslipidemia on a simple morphological feature extracted from photoplethysmography flow mediated dilation

    , Article International Conference in Electronic Engineering and Computing Technology, London, 1 July 2009 through 3 July 2009 ; Volume 60 LNEE , 2010 , Pages 551-561 ; 18761100 (ISSN) ; 9789048187751 (ISBN) Zaheditochai, M ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
    2010
    Abstract
    Dyslipidemia is considered to be one of the main heart risk factors, affecting the endothelial vascular function, which can be non-invasively investigated by ultrasound flow-mediated dilation (US-FMD). However, US-FMD comes at a high-cost and is operator-dependent. In this paper, the effect of dyslipidemia on the photoplethysmogram (PPG) signal recorded from collateral index fingers is investigated following a previous study where it was shown that results similar to that of US-FMD can be replicated by the PPG. Two groups, consisting of 30 healthy subjects free from any risk factors and 30 subjects who have only dyslipidemia as risk factor were respectively considered. The percent change in... 

    A statistical model to estimate flow mediated dilation using recorded finger photoplethysmogram

    , Article IFMBE Proceedings, 3 December 2008 through 6 December 2008 ; Volume 23 , 2009 , Pages 18-21 ; 16800737 (ISSN) ; 9783540928409 (ISBN) Jaafar, R ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
    Abstract
    Noninvasive measurement of brachial artery (BA) flow mediated dilation (FMD), commonly measured by high resolution ultrasonography, has provided a non-invasive means for the evaluation of endothelial function. Recently, another technique based on finger photopletysmogram (PPG) analysis has been proposed by the authors. In this paper, simultaneous measurement of BA FMD and PPG signals data from 86 human subjects (43 healthy and 43 risk) is analyzed and a statistical model is proposed to estimate the BA FMD based on PPG signals, the BA diameter at baseline as well as other demographics factors such as age and gender. Linear regression by multivariate analysis was conducted to obtain the... 

    A Physiological model-based study of flow-mediated dilation in peripheral arteries using finger photoplethysmogram signal

    , Article 2017 24th Iranian Conference on Biomedical Engineering and 2017 2nd International Iranian Conference on Biomedical Engineering, ICBME 2017, 30 November 2017 through 1 December 2017 ; 2018 ; 9781538636091 (ISBN) Habib Parsafar, M ; Zahedi, E ; Vosoughi Vahdat, B ; Sharif University of Technology
    Abstract
    Flow-mediated dilation measurement in the brachial artery using ultrasound imaging (FMD-US) is a common noninvasive procedure for endothelial function evaluation in the peripheral arteries. As FMD-US is operator-dependent and involves onerous equipment, its use has been mostly confined to research settings. In this paper, we propose to use the more accessible finger photoplethysmogram signal in conjunction with the FMD test (FMD-PPG) as a surrogate method. To this end, a tube-load physiological model of the upper arterial path in the arm is developed. Signals acquired from young and elderly subjects (N=20) are then investigated using model parameter estimation by the genetic algorithm. Our... 

    Discrimination between different degrees of coronary artery disease using time-domain features of the finger photoplethysmogram in response to reactive hyperemia

    , Article Biomedical Signal Processing and Control ; Volume 18 , 2015 , Pages 282-292 ; 17468094 (ISSN) Hosseini, Z. S ; Zahedi, E ; Movahedian Attar, H ; Fakhrzadeh, H ; Parsafar, M. H ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    Atherosclerosis is a major cause of coronary artery disease leading to morbidity and mortality worldwide. Currently, coronary angiography is considered to be the most accurate technique to diagnose coronary artery disease (CAD). However, this technique is an invasive and expensive procedure with risks of serious complications. Since the symptoms of CAD are not noticed until advanced stages of the disease, early and effective diagnosis of CAD is considered a pertinent measure. In this paper, a non-invasive optical signal, the finger photoplethysmogram (PPG) obtained before and after reactive hyperemia is investigated to discriminate between subjects with different CAD conditions. To this end,...