Loading...
Search for: fault-current-limiters
0.01 seconds

    Reliability study of HV substations equipped with the fault current limiter

    , Article IEEE Transactions on Power Delivery ; Vol. 27, issue. 2 , 2012 , p. 610-617 ; ISSN: 8858977 Fotuhi-Firuzabad, M ; Aminifar, F ; Rahmati, I ; Sharif University of Technology
    Abstract
    Of particular interest to restrict the short-circuit level of interconnected power systems is to exploit fault current limiter (FCL) technologies. FCLs let the system planners devise new reliable and rather economical substation configurations and provide the possibility of proposing a promising cost-effective and prompt solution to the fault current over duty problem in the existing substations. This paper attempts to assess reliability of substation architectures accommodating the FCL operation and, besides, numerically investigates the FCL's impacts on the substation reliability indices. In order to clarify the proposed approach, two case studies with and without FCL are analyzed and... 

    Reliability study of HV substations equipped with the fault current limiter

    , Article IEEE Transactions on Power Delivery ; Volume 27, Issue 2 , 2012 , Pages 610-617 ; 08858977 (ISSN) Fotuhi Firuzabad, M ; Aminifar, F ; Rahmati, I ; Sharif University of Technology
    2012
    Abstract
    Of particular interest to restrict the short-circuit level of interconnected power systems is to exploit fault current limiter (FCL) technologies. FCLs let the system planners devise new reliable and rather economical substation configurations and provide the possibility of proposing a promising cost-effective and prompt solution to the fault current over duty problem in the existing substations. This paper attempts to assess reliability of substation architectures accommodating the FCL operation and, besides, numerically investigates the FCL's impacts on the substation reliability indices. In order to clarify the proposed approach, two case studies with and without FCL are analyzed and... 

    Mechanical force optimization on superconductor element of shield-type superconducting FCLs

    , Article 2012 3rd Power Electronics and Drive Systems Technology, PEDSTC 2012, 15 February 2012 through 16 February 2012 ; February , 2012 , Pages 495-499 ; 9781467301114 (ISBN) Hekmati, A ; Vakilian, M ; Fardmanesh, M ; Sharif University of Technology
    2012
    Abstract
    Superconducting fault current limiter (SFCL) is classified in the category of most efficient fault current limiters. Inductive shield-type SFCLs use bulk superconductor rings in their structure. At the fault occurrence, the induced current in the superconductor ring causes high mechanical forces on the ring. In the preliminary fabricated prototypes of this work, this mechanical force caused several damages to the superconductor element. Thus in this paper an analytical method is introduced to yield the main design parameters of the shield-type SFCL to ensure the sufficient mechanical withstand capability of the superconductor ring employed in this design. A prototype SFCL of this type is... 

    Simulation of superconductive fault current limiter (SFCL) using modular neural networks

    , Article IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics, Paris, 6 November 2006 through 10 November 2006 ; 2006 , Pages 4415-4419 ; 1424401364 (ISBN); 9781424401369 (ISBN) Makki, B ; Sadati, N ; Sohani, M ; Sharif University of Technology
    2006
    Abstract
    Modular Neural Networks have had significant success in a wide range of applications because of their superiority over single non-modular ones in terms of proper data representation, feasibility of hardware implementation and faster learning. This paper presents a constructive multilayer neural network (CMNN) in conjunction with a Hopfield model using a new cost function to simulate the behavior of superconductive fault current limiters (SFCLs). The results show that the proposed approach can efficiently simulate the behavior of SFCLs. ©2006 IEEE  

    A series stacked IGBT switch to be used as a fault current limiter in HV high-power supplies

    , Article IEEE Journal of Emerging and Selected Topics in Power Electronics ; Volume 9, Issue 5 , 2021 , Pages 6300-6314 ; 21686777 (ISSN) Mohsenzade, S ; Zarghani, M ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    The safe operating condition for the vacuum tubes is very important and critical since they are very expensive and delicate. Providing limited short circuit energy for the vacuum tube and fast transferring from the short circuit to the nominal operation state are absolutely necessary. Extant protection strategies threat the availability of the vacuum tubes. In addition, they cannot completely protect the tube due to the delay of the fault detection system. This article proposes a high voltage (HV) short circuit fault current limiter which can limit the short circuit energy of the system inherently. The proposed structure activates automatically when the current exceeds the predetermined... 

    Proposed flux-based optimization method for determination of minimum superconductor material in shield-type superconducting fault current limiters

    , Article Scientia Iranica ; Volume 19, Issue 6 , December , 2012 , Pages 1843-1849 ; 10263098 (ISSN) Hekmati, A ; Vakilian, M ; Fardmanesh, M ; Sharif University of Technology
    2012
    Abstract
    Distributed power generation and an ever growing load demand have caused the current level of fault to exceed the nominal rating of power system devices, and fault current limiters are needed even more. The Superconducting Fault Current Limiter, SFCL, forms an efficient category of current limiters. The superconductor part in SFCLs is the most costly part of the device, and minimizing its volume, while maintaining the required characteristics of the device, would be very beneficial. In this work, using a Simulated Annealing optimization algorithm, a method has been proposed to determine minimum required bulk superconductor material in inductive shield-type SFCL structures. The flux linkage... 

    A novel method of flat YBCO rings development for shield-type superconducting fault current limiters fabrication

    , Article Physica C: Superconductivity and its Applications ; Volume 472, Issue 1 , January , 2012 , Pages 39-43 ; 09214534 (ISSN) Hekmati, A ; Hosseini, M ; Vakilian, M ; Fardmanesh, M ; Sharif University of Technology
    Abstract
    The application of flat superconductor rings has been investigated in the structure of inductive shield-type high temperature superconducting fault current limiters, HT c-SFCL. A laboratory scale inductive shield-type HT c-SFCL has been designed and fabricated using flat superconductor rings. The fabrication process has been fully presented. YBCO powder has been used for the fabrication of superconductor rings. This fabrication process, being quite innovative, is introduced completely. The method of the trapped field measurement has been used for the critical current density measurement of the fabricated superconductor rings. The device with nominal current of 2 A was tested in a 30 V... 

    Flux-based modeling of inductive shield-type high-temperature superconducting fault current limiter for power networks

    , Article IEEE Transactions on Applied Superconductivity ; Volume 21, Issue 4 , 2011 , Pages 3458-3464 ; 10518223 (ISSN) Hekmati, A ; Vakilian, M ; Fardmanesh, M ; Sharif University of Technology
    Abstract
    Distributed power generation and the ever-growing load demand have caused fault current levels to exceed the nominal rating of the power system devices, and fault current limiters are more needed. Superconducting fault current limiter (SFCL) forms an important category of current limiters. In this paper, a novel flux-based model for the inductive shield-type high-temperature SFCL is developed based on the Bean model. This model is employed to simulate the SFCL performance in a sample circuit. Utilizing the model, the signal characterization of the limited current is determined. A prototype laboratory scale SFCL has been fabricated with superconducting rings. Yttrium barium copper oxide... 

    Design and Fabrication of Inductive High Temperature Superconducting Fault Current Limiter

    , Ph.D. Dissertation Sharif University of Technology Hekmati, Arsalan (Author) ; Vakilian, Mehdi (Supervisor) ; Fardmanesh, Mehdi (Supervisor)
    Abstract
    The continuous rise in electricity demand and the ever growing power generation in different power networks over the world have caused the short circuit level in the power systems to exceed the operational rating of the installed power devices (including cables, circuit breakers and buses). Replacing these devices with new higher rating devices is an expensive solution. From this point of view, utilizing fault current limiters is an economical solution. Superconducting fault current limiters form an efficient category of current limiters. This type is expected to be studied and used widely in future due to their advantages. In this thesis, the first chapter reviews the superconductivity... 

    Modeling superconductive fault current limiter using constructive neural networks

    , Article 2007 IEEE International Symposium on Industrial Electronics, ISIE 2007, Caixanova - Vigo, 4 June 2007 through 7 June 2007 ; 2007 , Pages 2859-2863 ; 1424407559 (ISBN); 9781424407552 (ISBN) Makki, B ; Sadati, N ; Hosseini, M. N ; Sharif University of Technology
    2007
    Abstract
    Although so many advances have been proposed in the field of artificial intelligence and superconductivity, there are few reports on their combination. On the other hand, because of the nonlinear and multivariable characteristics of the superconductive elements and capabilities of neural networks in this field, it seems useful to apply the neural networks to model and control the superconductive phenomena or devices. In this paper, a new constructive neural network (CNN) trained by two different optimization algorithms; back-propagation and genetic algorithm, is proposed which models the behavior of the superconductive fault current limiters (SFCLs). Simulation results show that the proposed... 

    Micro-Grid Protection in Presence of Inverter Based Distributed Generation

    , M.Sc. Thesis Sharif University of Technology Zarei, Fariborz (Author) ; Parniani, Mostafa (Supervisor)
    Abstract
    In this study, control and protection of low voltage microgrids have been analyzed. Studied microgrid takes the advantages of inverter based distributed generation. One of the most important issues in inverter based microgrids is the control of its distributed generation. Since, the low voltage networks have single phase loads and many imbalances, these imbalances can affect the control of IBDGs (inverter based distributed generations). This issue in the islanded mode of operation is the most important, because in this mode of operation, IBDGs control the network voltage and frequency.
    In this thesis, the different control strategies of IBDGs are reviewed, and then modified to address... 

    Reducing the Flow Rate of Short Circuit Fault Current at the Output of the High Voltage Power Supply

    , M.Sc. Thesis Sharif University of Technology Zibarzani, Ali (Author) ; Kaboli, Shahriar (Supervisor)
    Abstract
    In this research, we have presented a method to delay the propagation of fault current in high voltage power supplies. Common protection methods usually protect the load and do not protect the power supply itself well. In this research, our goal was to propose a method to prevent the short circuit fault current from reaching the power supply elements. At first, the available methods to limit the fault current and protect the high voltage power sources were studied and investigated. Then, using the transmission line theory, a ladder filter was designed as an alternative to the normal filter at the output of the power supply. In the next step, using software simulation, the performance of the... 

    A voltage balancing method for series-connected igbts operating as a fault current limiter in high-voltage dc power supplies

    , Article IEEE Transactions on Industrial Electronics ; Volume 68, Issue 9 , 2021 , Pages 7895-7907 ; 02780046 (ISSN) Mohsenzade, S ; Zarghani, M ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    This article proposes a high-voltage fault current limiter (HVFCL) for high-voltage dc power supplies (HVdcPSs) which limits the current of the power supply automatically in the short-circuit fault (SCF). The proposed HVFCL is based on the series-connected insulated gate bipolar transistors (IGBTs). The main achievements of this article are the balanced voltage sharing and a very low value of the short-circuit current near to the load nominal current for the series-connected IGBTs during the SCF. These achievements result in a longer maximum permissible short-circuit time. These achievements are obtained by a control strategy that puts the series-connected IGBTs in a specific operating point... 

    Reliability enhancement in switching substations using fault current limiters

    , Article 2006 9th International Conference on Probabilistic Methods Applied to Power Systems, PMAPS, Stockholm, 11 June 2006 through 15 June 2006 ; 2006 ; 9171783520 (ISBN); 9789171783523 (ISBN) Rafi, S. B ; Fotuhi Firuzabad, M ; Sidhu, T. S ; Sharif University of Technology
    2006
    Abstract
    Power system equipments are normally designed for a specific system and load situation. This situation could change significantly as a result of the system expansion or aging. Among the system equipments, circuit breakers are more sensitive to the system expansion and they must be able to isolate the faulty components if a fault occurs. As the system load increases in the future, the power network must be expanded. In this situation, either the switching equipments must be replaced in order to be able to respond to the new fault current or the fault current must be limited to the interrupting capability of the existing circuit breakers. Application of Fault current Limiters (FCL) serves as a... 

    Reliability evaluation of HV substations in the presence of Fault Current Limiter

    , Article 2009 IEEE Bucharest PowerTech: Innovative Ideas Toward the Electrical Grid of the Future, 28 June 2009 through 2 July 2009 ; 28 June-2 July , 2009 ; 9781424422357 (ISBN) Rahmati, I ; Fotuhi Firuzabad, M ; Sharif University of Technology
    Abstract
    Short circuit current is one of the major threats for power system stability. Power system should have the ability to detect and clear these faults within a specified time. The protection system can clear the faults only if the interruption capability of the circuit breakers is higher than the fault level. Expansion of the grid and installation of new power on the scale that is envisaged will require practical solutions to a number of technical challenges. One of the technical challenges is fault level management as system expansion often results in increased fault levels beyond the design limits of the existing switchgears. Replacing the old equipments particularly circuit breakers with the... 

    Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme

    , Article IEEE Transactions on Power Delivery ; 2018 ; 08858977 (ISSN) Zarei, F ; Mokhtari, H ; Ghasemi, M. A ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In... 

    Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme

    , Article IEEE Transactions on Power Delivery ; Volume 34, Issue 5 , 2019 , Pages 1827-1842 ; 08858977 (ISSN) Zarei, S. F ; Mokhtari, H ; Ghasemi, M. A ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In... 

    A comprehensive design of the thyristor-based crowbar for vacuum tube high-voltage dc power supplies

    , Article IEEE Transactions on Plasma Science ; Volume 48, Issue 6 , 2020 , Pages 2202-2209 Pouresmaeil, K ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    High-voltage power supplies (HVPSs) are widely used to drive vacuum tubes, inherently susceptible to vacuum arc faults. Owing to the considerable cost of vacuum tubes, the HVPS should enjoy a reliable, fast protection mechanism. A common protection mechanism against vacuum arc faults is the shunt crowbar. The crowbar diverts the energy stored in the elements of the HVPS through itself as a parallel path, thereby protecting vacuum tubes from irrecoverable damages. Among all types of the shunt crowbar, the thyristor-based crowbar along with the fault current limiter (FCL) resistors attracts more attention because of its more reliable operation. The absence of the comprehensive design procedure...