Loading...
Search for: electrical-analogy
0.004 seconds

    Exact simulating of human arteries using lumped model and probing constriction in femoral and carotid arteries

    , Article American Journal of Applied Sciences ; Volume 6, Issue 5 , 2009 , Pages 834-842 ; 15469239 (ISSN) Mirzaee, M. R ; Ghasemalizadeh, O ; Firoozabadi, B ; Sharif University of Technology
    2009
    Abstract
    Problem statement: Modeling Human cardiovascular system was always an important issue from long past because by doing such modeling, investigation in cardiovascular system and its abnormities would be simpler. One of the most effective ways to do such modeling is using lumped method (Electrical analogy). Approach: Lumped method was used for simulating a complete model in this approach. A 36-vessel model was chosen to make equivalent circuit of lumped method from it. This complicated circuit includes equivalent segment for arteries, pulmonary, atrium, left and right ventricles. Furthermore, in this complex circuit some additional points were considered to improve this method. Some of the most... 

    Performance of valveless diffuser micropumps under harmonic piezoelectric actuation

    , Article 8th Biennial ASME Conference on Engineering Systems Design and Analysis, ESDA2006, Torino, 4 July 2006 through 7 July 2006 ; Volume 2006 , 2006 ; 0791837793 (ISBN); 9780791837795 (ISBN) Ahmadian, M. T ; Saidi, M. H ; Mehrabian, A ; Bazargan, M ; Kenarsari, S. D ; Sharif University of Technology
    American Society of Mechanical Engineers  2006
    Abstract
    Valveless piezoelectric micropumps are in wide practical use due to their ability to conduct particles with absence of interior moving mechanical parts. The objective of this paper is to obtain the fluid flow response to actuation frequency of a passive diffuser valve under harmonic pressures. In this regards a 2D model of a micropump valves and chambers is analyzed. The analysis is performed for 10Kpa back pressure on micropump chamber and actuation frequencies within the range of 1Hz to 10 KHz. Results show the highest velocity in the direction of diffuser axis occurs at the narrow diffuser neck while flow direction reverses every half period. For low frequencies, a parabolic velocity... 

    Electrical analog model of arterial compliance during reactive hyperemia

    , Article 2011 1st Middle East Conference on Biomedical Engineering, MECBME 2011, 21 February 2011 through 24 February 2011, Sharjah ; 2011 , Pages 49-53 ; 9781424470006 (ISBN) Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    2011
    Abstract
    Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog... 

    Electrical analogies applied on MMR micropump

    , Article Sensors and Actuators, A: Physical ; Volume 301 , 2020 Karmozdi, M ; Afshin, H ; Shafii, M. B ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Micropumps are among useful equipment in microsystems. The magnetically actuated mercury micropump, which has been introduced for less than a decade, is an innovative kind of micropumps which uses mercury droplets motion as a pumping agent. The equations governing this micropump are complex and their numerical solution is a time-consuming process, due to electromagnetic, hydrodynamic, and unsteady effects. In the present study, for the first time, using simplifying assumptions, the performance of a Magneto Mercury Reciprocating (MMR) micropump with electromagnetic actuation is studied through electrical analogy and then, the components and operational stages of the micropump are simulated... 

    Beat pressure and comparing it with ascending aorta pressure in normal and abnormal conditions

    , Article 4th European Conference of the International Federation for Medical and Biological Engineering, ECIFMBE 2008, Antwerp, 23 November 2008 through 27 November 2008 ; Volume 22 , 2008 , Pages 276-285 ; 16800737 (ISSN); 9783540892076 (ISBN) Ghasmelizadeh, O ; Mirzaee, M. R ; Firoozabadi, B ; Sajadi, B ; Zolfonoon, A ; Sharif University of Technology
    2008
    Abstract
    Lumped method (Electrical analogy) is a quick and easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that could show hydrodynamic parameters of cardiovascular system. Also this paper includes modeling of pulmonary, atrium, left and right ventricles with their equivalent circuits. Exact modeling of right and left ventricles pressure with division of ascending aorta into 27 segments increases the accuracy of our simulation. In this paper we show that a calculated pressure for aorta from our complex circuit is near to measured pressure by using advanced... 

    Exact modeling of cardiovascular system using lumped method

    , Article 2008 International Conference on Bioinformatics and Computational Biology, BIOCOMP 2008, Las Vegas, NV, 14 July 2008 through 17 July 2008 ; 2008 , Pages 408-417 ; 1601320558 (ISBN); 9781601320551 (ISBN) Ghasemalizadeh, O ; Mirzaee, M. R ; Firoozabadi, B ; Hassani, K ; Sharif University of Technology
    2008
    Abstract
    Electrical analogy (Lumped method) is an easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that could show hydrodynamic parameters of cardiovascular system. Also this paper includes modeling of pulmonary, atrium, left and right ventricles with their equivalent circuits. Exact modeling of right and left ventricles pressure increases the accuracy of our simulation. In this paper we show that a calculated pressure for aorta from our complex circuit is near to measured pressure by using advanced medical instruments  

    Study on Motion of Electrical Conductor Fluid Plug Actuated Electromagnetically in Microsystems

    , Ph.D. Dissertation Sharif University of Technology Karmozdi, Mohsen (Author) ; Shafii, Mohmmad Behshad (Supervisor) ; Afshin, Hossein (Supervisor)
    Abstract
    Micropumps are regarded as one of the devices used in microsystems, which are responsible for pumping working fluid. The Mercury Magneto Reciprocating (MMR) micropump, which has been introduced for less than a decade, is an innovative kind of micropumps which the pumping agent includes three liquid metal droplets (LMD) placed inside lateral chambers and reciprocated by the electromagnetic force inside the chambers. The working fluid located inside the main channel is pumped through due to the movement of these three LMDs. The equations governing this micropump are complex and their numerical solution is a time-consuming process, due to electromagnetic, hydrodynamic, and unsteady effects. The...