Loading...
Search for: eccentric-muscle-contraction
0.005 seconds

    The effect of temperature on eccentric contraction-induced isometric force loss in isolated perfused rat medial gastrocnemius muscle

    , Article Tehran University Medical Journal ; Volume 66, Issue 6 , 2008 , Pages 388-395 ; 16831764 (ISSN) Vasaghi Gharamaleki, B ; Keshavarz, M ; Gharibzadeh, S ; Marvi, H ; Mosayebnejad, J ; Ebrahimi Takamjani, E ; Sharif University of Technology
    Tehran University of Medical Sciences  2008
    Abstract
    Background: The typical features of eccentric exercise-induced muscle damage are delayed-onset muscle soreness (DOMS) and prolonged loss of muscle strength. It has been shown that passive warmth is effective in reducing muscle injury. Due to the interaction of different systems in vivo, we used isolated perfused medial gastrocnemius skeletal muscle to study the direct effect of temperature on the eccentric contraction-induced force loss. Methods: After femoral artery cannulation of a rat, the left medial gastrocnemius muscle was separated and then the entire lower limb was transferred into a prewarmed (35oC) chamber. With the chamber temperature at 31, 35 and 39oC before and during eccentric... 

    The influence of temperature alterations on eccentric contraction-induced isometric force and desmin loss in ratmedial gastrocnemius muscle

    , Article Journal of Medical Sciences ; Volume 8, Issue 2 , 2008 , Pages 162-169 ; 16824474 (ISSN) Vasaghi Gharamaleki, B ; Keshavarz, M ; Gharibzadeh, S ; Sotodeh, M ; Marvi, H ; Mosayebnejad, J ; Ebrahimi Takamjani, I ; Sharif University of Technology
    2008
    Abstract
    In this study isolated perfused rat muscle was used to examine the direct effect of temperature changes on the eccentric contraction-induced force and desmin loss. The left medial gastrocnemius muscle was separated and the entire lower limb was transferred into a prewarmed (35°C) organ bath. Temperature was adjusted to 31 or 39°C before and during eccentric contractions. Maximal isometric force and desmin loss were measured after 15 isometric or eccentric contractions. According to our data, organ bath temperature changes before or during eccentric contractions had no significant effect on force loss. However, a strong correlation between desmin loss and temperature changes before (r = 0.93,... 

    Comparisons of lumbar spine loads and kinematics in healthy and non-specific low back pain individuals during unstable lifting activities

    , Article Journal of Biomechanics ; Volume 144 , 2022 ; 00219290 (ISSN) Heidari, E ; Arjmand, N ; Kahrizi, S ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Evaluation of spinal loads in patients with low back pain (LBP) is essential to prevent further lumbar disorders. Many studies have investigated the relationship between lifting task variables and lumbar spine loads during manual lifting activities. The nature of the external load (stable versus unstable loads) is an important variable that has received less attention. Therefore, the present study aimed to measure trunk kinematics and estimate compressive-shear loads on the lumbar spine under lifting a 120 N stable load and 120 ± 13.63 N sensual unstable load in 16 healthy and 16 non-specific LBP individuals during lifting activities. The maximal lumbar loads were estimated using a...