Loading...
Search for: common-mode-voltage
0.004 seconds

    Improvement of post-fault performance of a cascaded h-bridge multilevel inverter

    , Article IEEE Transactions on Industrial Electronics ; Volume 64, Issue 4 , 2017 , Pages 2779-2788 ; 02780046 (ISSN) Ouni, S ; Zolghadri, M. R ; Khodabandeh, M ; Shahbazi, M ; Rodríguez, J ; Oraee, H ; Lezana, P ; Schmeisser, A. U ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    This paper is focused on improving the post-fault performance of cascaded H-bridge multilevel inverters by decreasing the common-mode voltage. First, an algorithm is proposed to determine the optimal post-fault state among all possible states, which have the same maximum available voltage. Furthermore, a modified technique is proposed to calculate the references of inverter phase voltages under faulty conditions. This technique leads to a decrease in the common-mode voltage when the required output voltage is less than its maximum value. These solutions are mutually employed in the post-fault control system. Simulation and experimental results confirm the effectiveness of the proposed... 

    Design and Implementation of Transformerless Grid Connected PV Inverter with Mitigating Leakage Currents

    , M.Sc. Thesis Sharif University of Technology Amereh, Mohammad (Author) ; Zolghadri, Mohammad Reza (Supervisor)
    Abstract
    In recent years Photovoltaic Panels (PV) are very wide spread. Due to AC working mode of many consumers produce DC voltage of PV must be converted to AC voltage by inverters. Nowdays one of the most popular inverter topologies are grid connected transformerless inverters. The main task of transformer is galvanic isolation of PV from grid. These transformers are commonly work with grid frequency i.e 50 Hz, and consequently are bulky, heavy and expensive. Transformer elimination results in common mode leakage current from parasitic capacitors of PV cells and its grounded frame to the grid ground, that will cause in EMI and malfunction of earth fault relays.
    In this thesis the factors of... 

    Reduced common-mode voltage in Z-source inverters

    , Article 8th Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2017, 14 February 2017 through 16 February 2017 ; 2017 , Pages 413-418 ; 9781509057665 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Z-source family has been widespread in photovoltaic (PV) applications. In trasformerless grid-connected PV systems, the common mode voltage (CMV) time variations, cause the leakage current flow. This current flows through the stray capacitance of the PV panels. For a Z-Source Inverter (ZSI), the CMV would have higher high-frequency harmonics, due to the shoot through states within the switching cycles. In this paper, the CMV of a ZSI is analyzed and a simple method is proposed for the harmonic reduction of the CMV in the ZSI. The CMV reduction method is based on changing the switching states. The CMV in reduced method is compared to the CMV in the traditional ZSI in frequency domain by using... 

    A modulation method for leakage current reduction in a three-phase grid-tie quasi-Z-source inverter

    , Article IEEE Transactions on Power Electronics ; 2018 ; 08858993 (ISSN) Noroozi, N ; Yaghoubi, M ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic (PV) system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low and high-frequency harmonics which cause safety and EMI problems respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be simply filtered.... 

    Three-Phase quasi-Z-source inverter with constant common-mode voltage for photovoltaic application

    , Article IEEE Transactions on Industrial Electronics ; Volume 65, Issue 6 , 2018 , Pages 4790-4798 ; 02780046 (ISSN) Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In trasformerless grid-connected photovoltaic (PV) systems, common-mode voltage (CMV) fluctuations cause leakage current flow through the stray capacitance of the PV panels. Shoot-through states in a quasi-Z-source inverter (q-ZSI) increase the amplitude of high-order harmonics of CMV. In this paper, by using the modulation technique based on odd pulse width modulation and minor change in the Z network of the three-phase q-ZSI, the leakage current is blocked. No extra semiconductor element is added. By the proposed technique, CMV is kept nearly constant during switching cycles. The experimental results for CMV analysis in a 1kW prototype are presented to verify the theoretical analysis. ©... 

    A modulation method for leakage current reduction in a three-phase grid-tie quasi-z-source inverter

    , Article IEEE Transactions on Power Electronics ; Volume 34, Issue 6 , 2019 , Pages 5439-5450 ; 08858993 (ISSN) Noroozi, N ; Yaghoubi, M ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low-and high-frequency harmonics that cause safety and electromagnetic interference problems, respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be... 

    A new fault tolerant method for cascaded h-bridge inverters based on peak reduction post-fault control method

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; Pages 671-676 , 2019 ; 9781538692547 (ISBN) Babaloo, R ; Fathi, M ; Afjei, E ; Siadatan, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In This paper, a new post-fault control method for symmetric cascaded H-bridge multilevel inverters (CHB-MLIs) is proposed with the aim of the development of CHB-MLIs performance under faulty conditions due to decrease in common mode voltage (CMV). In other words, this technique addresses the exclusive process to select the optimal post-fault state among all available states possess the same amplitude of the output line to line voltages. As a result, this process leads to provide computed phase voltages references to apply to PWM block. Hence, this technique leads to decrease the common mode voltage and eliminate it under some desired output line-line voltages. Finally, the feasibility of... 

    Harmonic analysis of common-mode voltage in quasi-z-source inverters

    , Article 2019 IEEE International Conference on Industrial Technology, ICIT 2019, 13 February 2019 through 15 February 2019 ; Volume 2019-February , 2019 , Pages 1778-1783 ; 9781538663769 (ISBN) Noroozi, N ; Yaghoubi, M ; Davoodi, A ; Ouni, S ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In a transformerless grid-connected photovoltaic system, many issues arise from the leakage current flow into the ground, as EMI problems. The leakage current is originated from the common-mode voltage fluctuations. In this paper, the common-mode voltage harmonics in a three-phase quasi-Z-source inverter are analyzed using Fourier transform and a closed-loop formulation is presented for the harmonics value. The shoot-through mode in a quasi-Z-source inverter causes extra fluctuations in the common-mode voltage comparing to a classic inverter. The proposed harmonic analysis method provides a systematic way to figure out how shoot-through mode and also other parameters affect the common-mode... 

    Performance Improvement of Cascaded H-bridge Multilevel Inverter under Faulty Conditions

    , Ph.D. Dissertation Sharif University of Technology Ouni, Saeed (Author) ; Zolghadri, Mohammad Reza (Supervisor) ; Oraee Mirzamani, Hashem (Supervisor) ; Rodriguez, Jose (Co-Advisor)
    Abstract
    Fault-tolerant ability is more subjected in Cascaded H-Bridge Multilevel Inverter due to its high-power medium-voltage applications and large number of semiconductors switches used in its structure. In this thesis, the goal is performance improvement of Cascaded H-bridge Multilevel Inverter under faulty conditions. Since to achieve the post-fault ability two steps; fault detection and post-fault control are required, both steps are considered in the improving process. In this dissertation, first operation of Cascaded H-Bridge Multilevel Inverter in normal and faulty condition is surveyed. Then, the conventional fault detection methods are mentioned and post-fault control methods are... 

    An Analysis of Common Mode Voltage in Multi-level Matrix Converter

    , M.Sc. Thesis Sharif University of Technology Garousi, Bahram (Author) ; Oraee Mirzamani, Hashem (Supervisor)
    Abstract
    The matrix converter is an array of controlled bidirectional semi-conductor switches that allows direct ac–ac conversion without an intermediate dc link. This converter has several attractive features that have been investigated in the last two decades. Multilevel converter technology has become increasingly popular in recent years due to high power quality,high-voltage capability, low switching losses and low EMI issues.This paper is concerned with applying multilevel techniques to direct ac–ac power converters and concentrates on developing the concepts of space vector modulation for a multilevel matrix converter. The common-mode voltage produced by a modern power converter has been... 

    Comparison of common-mode voltage in three-phase quasi-Z-source inverters using different shoot-through implementation methods

    , Article Proceedings - 2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2018 ; 4 June , 2018 , Pages 1-6 ; 9781538625088 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In Z-source family inverters, shoot-through (ST) states are applied as a part of passive state in each switching cycle. The distribution of ST intervals along a switching period affects the system parameters as total harmonic distortion (THD), switching loss and common-mode voltage (CMV). In this paper, ST methods in a three-phase quasi-Z-source inverter (q-ZSI) are compared due to the CMV level. High-frequency harmonics of CMV cause leakage current flow in a transformerless grid-connected photovoltaic (PV) system. Through the comparison of the ST methods, the method with minimum CMV is identified. The experimental results are Prasented for a low voltage q-ZSI prototype. © 2018 IEEE  

    A low-power low-offset charge-sharing technique for double-tail comparators

    , Article Microelectronics Journal ; Volume 102 , August , 2020 Khorami, A ; Saeidi, R ; Sachdev, M ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    A charge sharing technique for high-speed double-tail comparators is presented. This technique is applied to the pre-amplifier stage of the dynamic comparators so that the maximum differential gain is applied to the latch during the latching process reducing the input referred offset voltage. In dynamic comparators a large portion of the input referred offset voltage is coming from the latch, and the proposed technique is introduced to alleviate this issue. Monte- Carlo simulations show that the proposed technique reduces the offset voltage from 16 mV to 8 mV. Due to the charge sharing technique, the pre-amplifier draws just enough power for its operation reducing the average power by 40%... 

    Design and Implementation of a Modular 3-Ph Grid Connected Solar Inverter

    , M.Sc. Thesis Sharif University of Technology Barmaki, Alireza (Author) ; Zolghadri, Mohammad Reza (Supervisor) ; Attarodi, Mojtaba (Co-Supervisor)
    Abstract
    Recently a new topology, namely “common ground inverter” is introduced which since it enjoys a direct connection between AC neutral and DC ground, essentially solves the problem of leakage current in grid connected applications. Moreover, a reduced implementation price and a simple control scheme is associated with this system. The Aforementioned features have absorbed a lot of attention for further research regarding this topology. In this research one of the three introduced topologies is considered in details and its function in supplying local loads and Grid is put to the test. Moreover, important efforts have been taken to improve the properties of the inverter in terms of efficiency,... 

    Performance Improvement of Grid-connected Quasi-Z-Source Photovoltaic Inverter to Reduce Leakage Currents

    , Ph.D. Dissertation Sharif University of Technology Noroozi, Negar (Author) ; Zolghadri, Mohammad Reza (Supervisor)
    Abstract
    A quasi-Z-source inverter is a beneficial structure in photovoltaic applications. In a transformerless grid-connected inverter system, the common-mode voltage fluctuations cause the leakage current flow through the ground. The low-frequency harmonics of the common-mode voltage results in the malfunction of the residual current device. On the other hand, the high-frequency harmonics of the common-mode voltage cause EMI problems, additional loss and disturbance in the output currents. In this thesis, some methods are presented to reduce the leakage current in a three-phase quasi-Z-source inverter. First, different shoot-through implementation methods are investigated. By modifying the number... 

    Improvement of Z-source and Quasi-z Source Inverter for Photovoltaic Applications

    , M.Sc. Thesis Sharif University of Technology Aseyedali, Mahdi (Author) ; Parniani, Mostafa (Supervisor)
    Abstract
    The Z-source and quasi-Z source inverter have a capability to increase and decrease the output voltage without using extra switching stages or transformer. Therefor these inverters are an excellent choice for applications such as photovoltaic sources because of their higher efficiency, higher reliability and lower volume and cost. One drawback of these inverters is the leakage current that causes undesirable effect on the power system and safety issues. In this research we are going to develop a new modulation method for these inverters to reject the leakage current. In this method the harmonic content of common mode voltage is concentrated on the switching frequency and its harmonics while... 

    Three-phase quasi-Z-source inverter with constant common-mode voltage for photovoltaic application

    , Article IEEE Transactions on Industrial Electronics ; 2017 ; 02780046 (ISSN) Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Abstract
    In trasformerless grid-connected photovoltaic (PV) systems, common-mode voltage (CMV) fluctuations cause leakage current flow through the stray capacitance of the PV panels. Shoot-through (SH) states in a quasi-Z-source inverter (q-ZSI), increase the amplitude of high order harmonics of CMV. In this paper, by using the modulation technique based on odd PWM (OPWM) and minor change in the Z network of the three-phase q-ZSI, the leakage current is blocked. No extra semiconductor element is added. By the proposed technique, CMV is kept nearly constant during switching cycles. The experimental results for CMV analysis in a 1kW prototype are presented to verify the theoretical analysis. IEEE  

    A novel modulation method for reducing common mode voltage in three-phase inverters

    , Article Conference Proceedings - 2017 17th IEEE International Conference on Environment and Electrical Engineering and 2017 1st IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2017, 6 June 2017 through 9 June 2017 ; 2017 ; 9781538639160 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Abstract
    Leakage current is originated from common-mode voltage (CMV) time variations in a grid-connected photovoltaic (PV) system and results in several deficiencies. In this paper, a new method is proposed for CMV reduction in a three-phase voltage source inverter (VSI) system. The proposed method is based on space vector modulation and it utilizes only odd and zero vectors. By using the proposed method, the number of fluctuations of the CMV waveform per switching cycle is reduced; therefore, the amount of high-frequency harmonics of CMV is decreased. In addition, because of applying both active and zero vectors by the proposed method, the total harmonic distortion becomes less than most of other... 

    An ultra low-power DAC with fixed output common mode voltage

    , Article AEU - International Journal of Electronics and Communications ; Volume 96 , 2018 , Pages 279-293 ; 14348411 (ISSN) Khorami, A ; Saeidi, R ; Sharifkhani, M ; Sharif University of Technology
    Elsevier GmbH  2018
    Abstract
    A novel structure of Capacitive Digital to Analog Converters (CDAC) for Successive Approximation Register Analog to Digital Converters (SAR ADC) is presented. In this CDAC, a number of pre-charged capacitors are placed in different series configurations to produce a desired voltage level. Therefore, given an input code, a series configuration of the capacitors is created to produce a voltage. Current is drawn from the supply voltage only in one step of the ADC conversion to reduce the power consumption. Therefore, the proposed CDAC consumes a fixed and small amount of power regardless of the input code. The output common mode voltage (Vcm) of the DAC remains fixed for all the digital codes.... 

    A low-power technique for high-resolution dynamic comparators

    , Article International Journal of Circuit Theory and Applications ; Volume 46, Issue 10 , 2018 , Pages 1777-1795 ; 00989886 (ISSN) Khorami, A ; Sharifkhani, M ; Sharif University of Technology
    John Wiley and Sons Ltd  2018
    Abstract
    A low-power technique for high-resolution comparators is introduced. In this technique, p-type metal-oxide-semiconductor field-effect transistors are employed as the input of the latch of the comparator just like the input of the preamplifier. The latch and preamplifier stages are activated in a special pattern using an inverter-based controller. Unlike the conventional comparator, the preamplification delay can be set to an optimum low value even if after the preamplification, the output voltages is less than n-channel metal-oxide semiconductor voltage threshold. As a result, the proposed comparator reduces the power consumption significantly and enhances the speed. The speed and power...