Loading...
Search for: clinical-observation
0.009 seconds

    Primary stenosis progression versus secondary stenosis formation in the left coronary bifurcation: a mechanical point of view

    , Article Biocybernetics and Biomedical Engineering ; Volume 39, Issue 1 , 2019 , Pages 188-198 ; 02085216 (ISSN) Jahromi, R ; Pakravan, H. A ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
    Elsevier Sp. z o.o  2019
    Abstract
    Biomechanical forces and hemodynamic factors influence the blood flow and the endothelial cells (ECs) morphology. These factors behave differently beyond the coronary artery stenosis. In the present study, unsteady blood flow in the left coronary artery (LCA) and its atherosclerotic bifurcating vessels, left anterior descending (LAD) and left circumflex (LCX) arteries, were numerically simulated to investigate the risk of plaque length development and secondary plaque formation in the post-stenotic areas. Using fluid–structure interaction (FSI) model, compliance of arterial wall and vessel curvature variations due to cardiac motion were considered. The arteries included plaques at the... 

    Primary stenosis progression versus secondary stenosis formation in the left coronary bifurcation: a mechanical point of view

    , Article Biocybernetics and Biomedical Engineering ; Volume 39, Issue 1 , 2019 , Pages 188-198 ; 02085216 (ISSN) Jahromi, R ; Pakravan, H. A ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
    Elsevier Sp. z o.o  2019
    Abstract
    Biomechanical forces and hemodynamic factors influence the blood flow and the endothelial cells (ECs) morphology. These factors behave differently beyond the coronary artery stenosis. In the present study, unsteady blood flow in the left coronary artery (LCA) and its atherosclerotic bifurcating vessels, left anterior descending (LAD) and left circumflex (LCX) arteries, were numerically simulated to investigate the risk of plaque length development and secondary plaque formation in the post-stenotic areas. Using fluid–structure interaction (FSI) model, compliance of arterial wall and vessel curvature variations due to cardiac motion were considered. The arteries included plaques at the... 

    Chemo-mechanistic multi-scale model of a three-dimensional tumor microenvironment to quantify the chemotherapy response of cancer

    , Article Biotechnology and Bioengineering ; Volume 118, Issue 10 , 2021 , Pages 3871-3887 ; 00063592 (ISSN) Nikmaneshi, M. R ; Firoozabadi, B ; Mozafari, A ; Sharif University of Technology
    John Wiley and Sons Inc  2021
    Abstract
    Exploring efficient chemotherapy would benefit from a deeper understanding of the tumor microenvironment (TME) and its role in tumor progression. As in vivo experimental methods are unable to isolate or control individual factors of the TME, and in vitro models often cannot include all the contributing factors, some questions are best addressed with mathematical models of systems biology. In this study, we establish a multi-scale mathematical model of the TME to simulate three-dimensional tumor growth and angiogenesis and then implement the model for an array of chemotherapy approaches to elucidate the effect of TME conditions and drug scheduling on controlling tumor progression. The... 

    Adjacent segments biomechanics following lumbar fusion surgery: a musculoskeletal finite element model study

    , Article European Spine Journal ; Volume 31, Issue 7 , 2022 , Pages 1630-1639 ; 09406719 (ISSN) Ebrahimkhani, M ; Arjmand, N ; Shirazi-Adl, A ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2022
    Abstract
    Purpose: This study exploits a novel musculoskeletal finite element (MS-FE) spine model to evaluate the post-fusion (L4–L5) alterations in adjacent segment kinetics. Methods: Unlike the existing MS models with idealized representation of spinal joints, this model predicts stress/strain distributions in all passive tissues while organically coupled to a MS model. This generic (in terms of musculature and material properties) model uses population-based in vivo vertebral sagittal rotations, gravity loads, and an optimization algorithm to calculate muscle forces. Simulations represent individuals with an intact L4–L5, a preoperative severely degenerated L4–L5 (by reducing the disc height by ~... 

    Atheroprone sites of coronary artery bifurcation: Effect of heart motion on hemodynamics-dependent monocytes deposition

    , Article Computers in Biology and Medicine ; Volume 133 , 2021 ; 00104825 (ISSN) Biglarian, M ; Firoozabadi, B ; Saidi, M. S ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    Atherosclerosis as a common cardiovascular disease is a result of both adverse hemodynamics conditions and monocyte deposition within coronary arteries. It is known that the adhesion of monocytes on the arterial wall and their interaction with the vascular surface are one of the main parameters in the initiation and progression of atherosclerosis. In this work, hemodynamic parameters and monocyte deposition have been investigated in a 3D computational model of the Left Anterior Descending coronary artery (LAD) and its first diagonal branch (D1) under the heart motion. A one-way Lagrangian approach is performed to trace the monocyte particles under different blood flow regimes and heart motion...