    High-throughput, label-free isolation of white blood cells from whole blood using parallel spiral microchannels with u-shaped cross-section

    , Article Biosensors ; Volume 11, Issue 11 , 2021 ; 20796374 (ISSN) Mehran, A ; Rostami, P ; Saidi, M. S ; Firoozabadi, B ; Kashaninejad, N ; Sharif University of Technology
    MDPI  2021
    Abstract
    Rapid isolation of white blood cells (WBCs) from whole blood is an essential part of any WBC examination platform. However, most conventional cell separation techniques are labor-intensive and low throughput, require large volumes of samples, need extensive cell manipulation, and have low purity. To address these challenges, we report the design and fabrication of a passive, label-free microfluidic device with a unique U-shaped cross-section to separate WBCs from whole blood using hydrodynamic forces that exist in a microchannel with curvilinear geometry. It is shown that the spiral microchannel with a U-shaped cross-section concentrates larger blood cells (e.g., WBCs) in the inner... 

    A metabonomics investigation of multiple sclerosis by nuclear magnetic resonance

    , Article Magnetic Resonance in Chemistry ; Volume 51, Issue 2 , DEC , 2013 , Pages 102-109 ; 07491581 (ISSN) Mehrpour, M ; Kyani, A ; Tafazzoli, M ; Fathi, F ; Joghataie, M. T ; Sharif University of Technology
    2013
    Abstract
    Multiple sclerosis (MS) is a nervous system disease that affects the fatty myelin sheaths around the axons of the brain and spinal cord, leading to demyelination and a broad range of signs and symptoms. MS can be difficult to diagnose because its signs and symptoms may be similar to other medical problems. To find out which metabolites in serum are effective for the diagnosis of MS, we utilized metabolic profiling using proton nuclear magnetic resonance spectroscopy (1H-NMR). Random forest (RF) was used to classify the MS patients and healthy subjects. Atomic absorption spectroscopy was used to measure the serum levels of selenium. The results showed that the levels of selenium were lower in... 

    Analytical and numerical evaluation of steady flow of blood through artery

    , Article Biomedical Research (India) ; Volume 24, Issue 1 , 2013 , Pages 88-98 ; 0970938X (ISSN) Sedaghatizadeh, N ; Barari, A ; Soleimani, S ; Mofidi, M ; Sharif University of Technology
    2013
    Abstract
    Steady blood flow through a circular artery with rigid walls is studied by COSSERAT Continuum Mechanical Approach. To obtain the additional viscosities coefficients, feed forward multi-layer perceptron (MLP) type of artificial neural networks (ANN) and the results obtained in previous empirical works is used. The governing filed equations are derived and solution to the Hagen-Poiseuilli flow of a COSSERAT fluid in the artery is obtained analytically by Homotopy Perturbation Method (HPM) and numerically using finite difference method. Comparison of analytical results with numerical ones showed excellent agreement. In addition microrotation and the velocity profile along the radius are... 

    Design and fabrication of a centrifugal microfluidic disc including septum valve for measuring hemoglobin A1c in human whole blood using immunoturbidimetry method

    , Article Talanta ; Volume 190 , 2018 , Pages 134-139 ; 00399140 (ISSN) Mahmodi Arjmand, E ; Saadatmand, M ; Bakhtiari, M. R ; Eghbal, M ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Diabetes mellitus is a global endemic with a rapidly increasing prevalence in both developing and developed countries. Recently, hemoglobin A1c has been recommended by the American Diabetes Associations as a possible substitute for fasting blood glucose for the diagnosis of diabetes, because it is an indicator of long-term glycemic control. Also, centrifugal microfluidic systems have good potential for use in the point of care testing systems. In this study, a centrifugal microfluidic disc was designed and manufactured to measure hemoglobin A1c in whole blood using an immunoturbidimetry based method. Also, a new passive valve, named septum valve, was presented to precisely control the entry... 

    Design and fabrication of an electrochemical aptasensor using Au nanoparticles/carbon nanoparticles/cellulose nanofibers nanocomposite for rapid and sensitive detection of Staphylococcus aureus

    , Article Bioelectrochemistry ; Volume 123 , 2018 , Pages 70-76 ; 15675394 (ISSN) Ranjbar, S ; Shahrokhian, S ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Since that pathogenic bacteria are major threats to human health, this paper describes the fabrication of an effective and durable sensing platform based on gold nanoparticles/carbon nanoparticles/cellulose nanofibers nanocomposite (AuNPs/CNPs/CNFs) at the surface of glassy carbon electrode for sensitive and selective detection of Staphylococcus aureus (S. aureus). The AuNPs/CNPs/CNFs nanocomposite with the high surface area, excellent conductivity, and good biocompatibility was used for self-assembled of the thiolated specific S. aureus aptamer as a sensing element. The surface morphology of AuNPs/CNPs/CNFs nanocomposite was characterized with field emission scanning electron microscopy...