Loading...
Search for: benzene--toluenes
0.006 seconds

    Degradation of benzene, toluene, and xylene (BTX) from aqueous solution by isolated bacteria from contaminated sites

    , Article Research on Chemical Intermediates ; Volume 41, Issue 1 , January , 2015 , Pages 265-275 ; 09226168 (ISSN) Mesgari Shadi, A ; Yaghmaei, S ; Vafaei, F ; Khataee, A. R ; Hejazi, M. S ; Sharif University of Technology
    Kluwer Academic Publishers  2015
    Abstract
    The present study was carried out to evaluate the degradation efficiency of benzene, toluene, and xylene (BTX) by isolated bacteria from various petroleum-hydrocarbons contaminated sites. Five isolated bacteria were selected for testing BTX biodegradation from liquid culture media. Each of these bacteria was able to degrade BTX but with different efficiencies. Maximum biodegradation efficiency for benzene (more than 70 %) was obtained by Gram-positive coccobacillus, Gram-positive coccus and Gram-negative bacillus bacteria, for toluene (60 %) and xylene (70 %) by Gram-positive coccobacillus and Gram-negative coccobacillus. It was found that the presence of xylene in the substrate mixture... 

    Degradation of BTEX in groundwater by nano-CaO2 particles activated with L-cysteine chelated Fe(III): enhancing or inhibiting hydroxyl radical generation

    , Article Water Supply ; Volume 21, Issue 8 , 2021 , Pages 4429-4441 ; 16069749 (ISSN) Sun, X ; Ali, M ; Cui, C ; Lyu, S ; Sharif University of Technology
    IWA Publishing  2021
    Abstract
    The simultaneous oxidation performance of benzene, toluene, ethylbenzene, and xylene (BTEX) by nanoscale calcium peroxide particles (nCaO2) activated with ferric ions (Fe(III)) and the mechanism of the enhancement of BTEX degradation by L-cysteine (L-cys) were investigated. The batch experimental results showed that the nCaO2/Fe(III)/L-cys process was effective in the destruction of BTEX in both ultrapure water and actual groundwater. A proper amount of L-cys could enhance BTEX degradation due to the promotion of Fe(II)/Fe(III) redox cycles by the participation of L-cys, but an excessive presence of L-cys would cause inhibition. Adding 1.0 mM L-cys to the nCaO2/Fe(III) system, the... 

    Analysis and interaction of exergy, environmental and economic in multi-objective optimization of BTX process based on evolutionary algorithm

    , Article Energy ; Volume 59 , 2013 , Pages 147-156 ; 03605442 (ISSN) Sahraei, M. H ; Farhadi, F ; Boozarjomehry, R. B ; Sharif University of Technology
    2013
    Abstract
    In this paper sustainability analysis (exergy, environmental and economic) and multi-objective optimization for an aromatic plant are provided and interactions between decision variables are discussed. Environmental evaluation shows that the cancer human toxicity and global warming are the most important environmental concerns and the weight of EIs (environmental impacts) are mainly due to process wastes. The optimizations results demonstrate parameters like reactor temperature have a wide range in the optimizations while some variables, such as extraction unit variables have the same value. Utility EI reduction occurred in economic and exergy optimizations rather than environmental... 

    Liquid-liquid-liquid microextraction followed by HPLC with UV detection for quantitation of ephedrine in urine

    , Article Journal of Separation Science ; Volume 31, Issue 18 , 2008 , Pages 3212-3217 ; 16159306 (ISSN) Bagheri, H ; Khalilian, F ; Ahangar, L. E ; Sharif University of Technology
    2008
    Abstract
    Liquid-liquid-liquid microextraction (LLLME) in combination with HPLC and UV detection has been used as a sensitive method for the determination of ephedrine in urine samples. Extraction process was performed in a homemade total glass vial without using a Teflon ring, usually employed. Ephedrine was first extracted from 3.5 mL of urine sample (pH 12) into a microfilm of toluene/benzene (50:50). The analyte was subsequently back extracted into an acidic microdrop solution (pH 2) suspended in the organic phase. The extract was then injected into the HPLC system directly. An enrichment factor of 137 along with a good sample clean-up was obtained under the optimized conditions. The calibration...