Loading...
Search for: artery-dilatation
0.008 seconds

    Finger photoplethysmogram pulse amplitude changes induced by flow-mediated dilation

    , Article Physiological Measurement ; Volume 29, Issue 5 , 2008 , Pages 625-637 ; 09673334 (ISSN) Zahedi, E ; Jaafar, R ; Mohd Ali, M. A ; Mohamed, A. L ; Maskon, O ; Sharif University of Technology
    2008
    Abstract
    This study was conducted to investigate the utility and efficacy of finger photoplethysmogram pulse amplitude (PPG-AC) in comparison with the standard Doppler ultrasound in assessing an endothelial function via flow-mediated dilation (FMD). High-resolution B-mode scanning of the right brachial artery (BA) of 31 healthy subjects aged 39.7 ± 11.3 (range 22-64) years and 52 risk subjects aged 47.7 ± 10.8 (range 30-65) years were performed before and after 4 min of upper arm occlusion. Concurrent with the ultrasound measurement (where color Doppler imaging was used to enhance arterial boundary detection), PPG signals were recorded from both index fingers for cross evaluation and comparison. Our... 

    Simulation of low density lipoprotein (LDL) permeation into multilayer coronary arterial wall: interactive effects of wall shear stress and fluid-structure interaction in hypertension

    , Article Journal of Biomechanics ; Volume 67 , 2018 , Pages 114-122 ; 00219290 (ISSN) Roustaei, M ; Nikmaneshi, M. R ; Firoozabadi, B ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Due to increased atherosclerosis-caused mortality, identification of its genesis and development is of great importance. Although, key factors of the origin of the disease is still unknown, it is widely believed that cholesterol particle penetration and accumulation in arterial wall is mainly responsible for further wall thickening and decreased rate of blood flow during a gradual progression. To date, various effective components are recognized whose simultaneous consideration would lead to a more accurate approximation of Low Density Lipoprotein (LDL) distribution within the wall. In this research, a multilayer Fluid-Structure Interaction (FSI) model is studied to simulate the penetration... 

    The effect of hematocrit and nanoparticles diameter on hemodynamic parameters and drug delivery in abdominal aortic aneurysm with consideration of blood pulsatile flow

    , Article Computer Methods and Programs in Biomedicine ; Volume 195 , October , 2020 Jafarzadeh, S ; Nasiri Sadr, A ; Kaffash, E ; Goudarzi, S ; Golab, E ; Karimipour, A ; Sharif University of Technology
    Elsevier Ireland Ltd  2020
    Abstract
    Background and Objective: The present article has simulated to investigate the efficient hemodynamic parameters, the drug persistence, and drug distribution on an abdominal aortic aneurysm. Methods: Blood as a non-Newtonian fluid enters the artery acting as a real pulse waveform; its behavior is dependent on hematocrit and strain rate. In this simulation of computational fluid dynamic, magnetic nanoparticles of iron oxide which were in advance coated with the drug, are injected into the artery during a cardiac cycle. A two-phase model was applied to investigate the distribution of these carriers. Results: The results are presented for different hematocrits and the nanoparticle diameter. It...