    Design, Fabrication and Model-base Control of a Brachiation Robot with Flexible Support

    , M.Sc. Thesis Sharif University of Technology Norouzi, Mohsen (Author) ; Vossoughi, Gholamreza (Supervisor) ; Namvar, Mehrzad (Supervisor)
    Abstract
    Nowadays, many researches are inspired by nature and living creatures in order to build various scientific and industrial products such as robots, because of the highest level of creativity which is used in creating them along with their high level of efficiency in power consumption and designing parameters. Underactuated Robots are the type of robots which have more degrees of freedom comparing to the number of operators. As a result their optimum control has a lot of complications. Brachiating robots are designed and built based on an inspiration from long armed apes (Gibbons). This type of monkey is highly skilled in twisting in trees and traversing. This type of movement benefits from... 

    Dynamic comparison of segmentary scapulohumeral rhythm between athletes with and without impingement syndrome

    , Article Iranian Journal of Radiology ; Vol. 11, issue. 2 , 2014 Taghizadeh Delkhoush, C ; Maroufi, N ; Ebrahimi Takamjani, I ; Farahmand, F ; Shakourirad, A ; Haghani, H ; Sharif University of Technology
    Abstract
    Background: Patients who have shoulder pain usually have compensatory or contributory deviation of shoulder motion during arm elevation. In the traditional scapulohumeral rhythm, the share of the acromioclavicular (AC) and the sternoclavicular (SC) joint movements and also the role of AC internal rotation angle are unknown. Objectives: The main purpose of this study was to measure and compare the segmentary scapulohumeral rhythm (SSHR) during scapular arm elevation at a steady rotational speed in athletes with and without impingement syndrome. Patients and Methods: Using a speedometer, the maximum speed of arm elevation was measured in 21 men in each of the involved and uninvolved groups.... 

    Human arm motion tracking by inertial/magnetic sensors using unscented Kalman filter and relative motion constraint

    , Article Journal of Intelligent and Robotic Systems: Theory and Applications ; Volume 90, Issue 1-2 , May , 2018 , Pages 161-170 ; 09210296 (ISSN) Atrsaei, A ; Salarieh, H ; Alasty, A ; Abediny, M ; Sharif University of Technology
    Springer Netherlands  2018
    Abstract
    Human motion tracking has many applications in biomedical and industrial services. Low-cost inertial/magnetic sensors are widely used in human motion capture systems to obtain the orientation of the human body segments. In this paper, we have presented a quaternion-based unscented Kalman filter algorithm to fuse inertial/magnetic sensors measurements for tracking human arm movements. In order to have a better estimation of the orientation of the forearm and the upper arm, a constraint equation was developed based on the relative velocity of the elbow joint with respect to the inertial sensors attached to the forearm and the upper arm. Also to compensate for fast body motions, we adapted the... 

    An exploratory study to design a novel hand movement identification system

    , Article Computers in Biology and Medicine ; Volume 39, Issue 5 , 2009 , Pages 433-442 ; 00104825 (ISSN) Khezri, M ; Jahed, M ; Sharif University of Technology
    2009
    Abstract
    Electromyogram signal (EMG) is an electrical manifestation of contractions of muscles. Surface EMG (sEMG) signal collected from the surface of skin has been used in diverse applications. One of its usages is in pattern recognition of hand prosthesis movements. The ability of current prosthesis devices has been generally limited to simple opening and closing tasks, minimizing their efficacy compared to natural hand capabilities. In order to extend the abilities and accuracy of prosthesis arm movements and performance, a novel sEMG pattern recognizing system is proposed. To extract more pertinent information we extracted sEMGs for selected hand movements. These features constitute our main... 

    Normal postural responses preceding shoulder flexion: Co-activation or asymmetric activation of transverse abdominis?

    , Article Journal of Back and Musculoskeletal Rehabilitation ; Vol. 27, issue. 4 , 2014 , p. 545-551 Davarian, S ; Maroufi, N ; Ebrahimi, E ; Parnianpour, M ; Farahmand, F ; Sharif University of Technology
    Abstract
    BACKGROUND AND OBJECTIVES: It is suggested that activation of the transverse abdominis muscle has a stabilizing effect on the lumbar spine by raising intra-abdominal pressure without added disc compression. However, its feedforward activity has remained a controversial issue. In addition, research regarding bilateral activation of trunk muscles during a unilateral arm movement is limited. The aim of this study was to evaluate bilateral anticipatory activity of trunk muscles during unilateral arm flexion.MATERIALS AND METHODS: Eighteen healthy subjects (aged 25 ± 3.96 years) participated in this study and performed 10 trials of rapid arm flexion in response to a visual stimulus. The... 

    A novel stability and kinematics-driven trunk biomechanical model to estimate muscle and spinal forces

    , Article Medical Engineering and Physics ; Vol. 36, issue. 10 , 2014 , p. 1296-1304 Hajihosseinali, M ; Arjmand, N ; Shirazi-Adl, A ; Farahmand, F ; Ghiasi, M. S ; Sharif University of Technology
    Abstract
    An anatomically detailed eighteen-rotational-degrees-of-freedom model of the human spine using optimization constrained to equilibrium and stability requirements is developed and used to simulate several symmetric tasks in upright and flexed standing postures. Predictions of this stability and kinematics-driven (S. +. KD) model for trunk muscle forces and spine compressive/shear loads are compared to those of our existing kinematics-driven (KD) model where both translational and rotational degrees-of-freedom are included but redundancy is resolved using equilibrium conditions alone. Unlike the KD model, the S. +. KD model predicted abdominal co-contractions that, in agreement with... 

    On the dynamics of the flexible robot arm in a real deployment profile

    , Article 2010 IEEE International Conference on Robotics, Automation and Mechatronics, RAM 2010, Singapore, 28 June 2010 through 30 June 2010 ; 2010 , Pages 112-117 ; 9781424465033 (ISBN) Bagheri Ghaleh, P ; Malaek, S. M ; Sharif University of Technology
    2010
    Abstract
    The dynamics of the flexible robot arm subjected to tip mass during an actual deployment is studied. The Euler-Bernoulli beam theory and the real deployment are considered in the simulation. A new real axial velocity profile is developed. This new suggested profile simulates the actual deployment such that the arm movement starts from immovability and after attaining the final required length comes back again to the static state. Using Lagrange's equation, the equations of motion of the system are derived to study the system dynamics in this suggested deployment profile. A series approximation is used to represent the lateral elastic displacements. Using variables separation and also some... 

    Human arm motion tracking by inertial/magnetic sensors using unscented kalman filter and relative motion constraint

    , Article Journal of Intelligent and Robotic Systems: Theory and Applications ; 2017 , Pages 1-10 ; 09210296 (ISSN) Atrsaei, A ; Salarieh, H ; Alasty, A ; Abediny, M ; Sharif University of Technology
    Abstract
    Human motion tracking has many applications in biomedical and industrial services. Low-cost inertial/magnetic sensors are widely used in human motion capture systems to obtain the orientation of the human body segments. In this paper, we have presented a quaternion-based unscented Kalman filter algorithm to fuse inertial/magnetic sensors measurements for tracking human arm movements. In order to have a better estimation of the orientation of the forearm and the upper arm, a constraint equation was developed based on the relative velocity of the elbow joint with respect to the inertial sensors attached to the forearm and the upper arm. Also to compensate for fast body motions, we adapted the... 

    The 2017 and 2018 Iranian Brain-Computer interface competitions

    , Article Journal of Medical Signals and Sensors ; Volume 10, Issue 3 , 2020 , Pages 208-216 Aghdam, N ; Moradi, M ; Shamsollahi, M ; Nasrabadi, A ; Setarehdan, S ; Shalchyan, V ; Faradji, F ; Makkiabadi, B ; Sharif University of Technology
    Isfahan University of Medical Sciences(IUMS)  2020
    Abstract
    This article summarizes the first and second Iranian brain-computer interface competitions held in 2017 and 2018 by the National Brain Mapping Lab. Two 64-channel electroencephalography (EEG) datasets were contributed, including motor imagery as well as motor execution by three limbs. The competitors were asked to classify the type of motor imagination or execution based on EEG signals in the first competition and the type of executed motion as well as the movement onset in the second competition. Here, we provide an overview of the datasets, the tasks, the evaluation criteria, and the methods proposed by the top-ranked teams. We also report the results achieved with the submitted algorithms...